{"id":21702,"date":"2020-07-21T11:51:39","date_gmt":"2020-07-21T11:51:39","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/detector-de-germanio-de-alta-pureza-hpge-definicao\/"},"modified":"2021-07-03T07:56:49","modified_gmt":"2021-07-03T07:56:49","slug":"detector-de-germanio-de-alta-pureza-hpge-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/","title":{"rendered":"Detector germ\u00e2nio hiper-puro &#8211; HPGe"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Detectores germ\u00e2nio hiper-puro (detectores HPGe) s\u00e3o a melhor solu\u00e7\u00e3o para espectroscopia precisa de raios gama e raios-x. Os detectores HPGe devem operar a temperaturas muito baixas de nitrog\u00eanio l\u00edquido. Dosimetria de Radia\u00e7\u00e3o<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<figure id=\"attachment_26112\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26112\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium.png\"><img loading=\"lazy\" class=\"size-medium wp-image-26112 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" alt=\"Detector HPGe - Germ\u00e2nio\" width=\"300\" height=\"204\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" \/><\/a><figcaption id=\"caption-attachment-26112\" class=\"wp-caption-text\">Detector HPGe com criostato LN2 Fonte: canberra.com<\/figcaption><\/figure>\n<p><strong>Detectores germ\u00e2nio hiper-puro<\/strong>\u00a0(\u00a0<strong>detectores\u00a0<\/strong><strong>HPGe<\/strong>\u00a0) s\u00e3o a melhor solu\u00e7\u00e3o para\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\">espectroscopia<\/a>\u00a0precisa de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\">raios gama e raios-x<\/a>\u00a0.\u00a0Em compara\u00e7\u00e3o com os\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/silicon-based-semiconductor-detectors\/\">detectores de sil\u00edcio<\/a>\u00a0, o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/germanium-as-semiconductor-properties\/\">germ\u00e2nio<\/a>\u00a0\u00e9 muito mais eficiente do que o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/silicon-as-semiconductor-properties\/\">sil\u00edcio<\/a>\u00a0para a detec\u00e7\u00e3o de radia\u00e7\u00e3o devido ao seu n\u00famero at\u00f4mico ser muito maior que o sil\u00edcio e \u00e0 menor energia m\u00e9dia necess\u00e1ria para criar um\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/electron-hole-pair\/\">par de el\u00e9trons-orif\u00edcios<\/a>\u00a0, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.\u00a0Devido ao seu n\u00famero at\u00f4mico mais alto, o\u00a0<strong>Ge<\/strong>\u00a0possui um coeficiente de atenua\u00e7\u00e3o linear muito maior, o que leva a um caminho livre m\u00e9dio mais curto.\u00a0Al\u00e9m disso, os detectores de sil\u00edcio n\u00e3o podem ser mais grossos do que alguns mil\u00edmetros, enquanto o germ\u00e2nio pode ter um esgotamento,<strong>espessura sens\u00edvel de cent\u00edmetros<\/strong>\u00a0e, portanto, pode ser usado como um detector de absor\u00e7\u00e3o total para raios gama de at\u00e9 poucos MeV.<\/p>\n<p>Antes que as atuais t\u00e9cnicas de purifica\u00e7\u00e3o fossem refinadas, os\u00a0<strong>cristais de germ\u00e2nio<\/strong>\u00a0n\u00e3o podiam ser produzidos com pureza suficiente para permitir seu uso como detectores de espectroscopia.\u00a0A pureza de um material detector \u00e9 da maior import\u00e2ncia.\u00a0A coleta de pares de el\u00e9trons e orif\u00edcios no detector deve ser realizada dentro de um prazo razoavelmente curto.\u00a0Al\u00e9m disso, n\u00e3o deve haver armadilhas que os impe\u00e7am de alcan\u00e7ar os contatos de coleta.\u00a0Os centros de captura podem ser devidos a:<\/p>\n<ul>\n<li>Impurezas na rede de semicondutores<\/li>\n<li>\u00c1tomos e vagas intersticiais na rede devido a defeitos estruturais<\/li>\n<li>\u00c1tomos intersticiais causados \u200b\u200bpor dano por radia\u00e7\u00e3o<\/li>\n<\/ul>\n<p>As impurezas nos cristais ret\u00eam el\u00e9trons e orif\u00edcios, prejudicando o desempenho dos detectores.\u00a0Consequentemente, os cristais de germ\u00e2nio foram dopados com \u00edons de l\u00edtio (Ge (Li)), a fim de produzir uma regi\u00e3o intr\u00ednseca na qual os el\u00e9trons e buracos seriam capazes de alcan\u00e7ar os contatos e produzir um sinal.<\/p>\n<p>Para obter a m\u00e1xima efici\u00eancia, os\u00a0<strong>detectores de HPGe<\/strong>\u00a0devem operar a temperaturas muito baixas de nitrog\u00eanio l\u00edquido (-196 \u00b0 C), porque, \u00e0 temperatura ambiente, o ru\u00eddo causado pela excita\u00e7\u00e3o t\u00e9rmica \u00e9 muito alto.<\/p>\n<p>Como os detectores HPGe produzem a mais alta resolu\u00e7\u00e3o comumente dispon\u00edvel atualmente, eles s\u00e3o usados \u200b\u200bpara medir radia\u00e7\u00e3o em diversas aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental de contamina\u00e7\u00e3o radioativa, aplica\u00e7\u00f5es m\u00e9dicas, ensaio radiom\u00e9trico, seguran\u00e7a nuclear e seguran\u00e7a de usinas nucleares.<\/p>\n<h2>Pe\u00e7as dos detectores HPGe<\/h2>\n<p>A principal desvantagem dos detectores de germ\u00e2nio \u00e9 que eles devem ser resfriados a temperaturas de nitrog\u00eanio l\u00edquido.\u00a0Como o germ\u00e2nio possui um\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/band-gap-energy-gap\/\">intervalo de banda<\/a>\u00a0relativamente baixo\u00a0, esses detectores devem ser resfriados para reduzir a gera\u00e7\u00e3o t\u00e9rmica de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\">portadores<\/a>\u00a0de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\">carga<\/a>\u00a0para um n\u00edvel aceit\u00e1vel.\u00a0Caso contr\u00e1rio, o ru\u00eddo induzido pela corrente de fuga destr\u00f3i a resolu\u00e7\u00e3o de energia do detector.\u00a0Lembre-se, a diferen\u00e7a de banda (uma dist\u00e2ncia entre a\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/conduction-and-valence-band-in-semiconductors\/\">val\u00eancia e a banda de condu\u00e7\u00e3o<\/a>\u00a0) \u00e9 muito baixa para o germ\u00e2nio (Egap = 0,67 eV).\u00a0O resfriamento at\u00e9 a temperatura do nitrog\u00eanio l\u00edquido (-195,8 \u00b0 C; -320 \u00b0 F) reduz as excita\u00e7\u00f5es t\u00e9rmicas dos el\u00e9trons de val\u00eancia, de modo que apenas uma intera\u00e7\u00e3o de raios gama pode fornecer ao el\u00e9tron a energia necess\u00e1ria para atravessar o intervalo da banda e alcan\u00e7ar a banda de condu\u00e7\u00e3o.<\/p>\n<p>Portanto, os\u00a0<strong>detectores HPGe<\/strong>\u00a0geralmente s\u00e3o equipados com um\u00a0<strong>criostato<\/strong>\u00a0.\u00a0Os cristais de germ\u00e2nio s\u00e3o mantidos dentro de um recipiente de metal evacuado, conhecido como\u00a0<strong>suporte<\/strong>\u00a0do\u00a0<strong>detector<\/strong>\u00a0.\u00a0O suporte do detector e a &#8220;tampa&#8221; s\u00e3o finos para evitar a atenua\u00e7\u00e3o de f\u00f3tons de baixa energia.\u00a0O suporte \u00e9 geralmente feito de alum\u00ednio e normalmente tem 1 mm de espessura.\u00a0A tampa tamb\u00e9m \u00e9 geralmente feita de alum\u00ednio.\u00a0O cristal HPGe dentro do suporte est\u00e1 em contato t\u00e9rmico com uma haste de metal chamada\u00a0<strong>dedo frio<\/strong>\u00a0.\u00a0O dedo frio transfere o calor do conjunto do detector para o\u00a0reservat\u00f3rio de\u00a0nitrog\u00eanio l\u00edquido (LN\u00a0<sub>2<\/sub>\u00a0).\u00a0A combina\u00e7\u00e3o do recipiente de metal a v\u00e1cuo, o\u00a0<strong>dedo frio<\/strong>\u00a0e o\u00a0<strong>bal\u00e3o Dewar<\/strong>para o nitrog\u00eanio l\u00edquido criog\u00eanico \u00e9 chamado o\u00a0<strong>criostato<\/strong>.\u00a0O pr\u00e9-amplificador do detector de germ\u00e2nio \u00e9 normalmente inclu\u00eddo como parte do pacote de criostato.\u00a0Como o pr\u00e9-amplificador deve estar localizado o mais pr\u00f3ximo poss\u00edvel, para que a capacit\u00e2ncia geral possa ser minimizada, o pr\u00e9-amplificador \u00e9 instalado juntos.\u00a0Os est\u00e1gios de entrada do pr\u00e9-amplificador tamb\u00e9m s\u00e3o resfriados.\u00a0O dedo frio se estende al\u00e9m do limite de v\u00e1cuo do criostato para um bal\u00e3o Dewar que \u00e9 preenchido com nitrog\u00eanio l\u00edquido.\u00a0A imers\u00e3o do dedo frio no nitrog\u00eanio l\u00edquido mant\u00e9m o cristal HPGe a uma temperatura baixa constante.\u00a0A temperatura do nitrog\u00eanio l\u00edquido \u00e9 mantida constante a 77 K (-195,8 \u00b0 C; -320 \u00b0 F) por ebuli\u00e7\u00e3o lenta do l\u00edquido, resultando na evolu\u00e7\u00e3o do g\u00e1s nitrog\u00eanio.\u00a0Dependendo do tamanho e design, o tempo de espera dos frascos a v\u00e1cuo varia de algumas horas a algumas semanas.<\/p>\n<p>O resfriamento com nitrog\u00eanio l\u00edquido \u00e9 inconveniente, pois o detector requer horas para esfriar at\u00e9 a temperatura operacional antes de poder ser usado e n\u00e3o pode aquecer durante o uso.\u00a0Os detectores HPGe podem aquecer at\u00e9 a temperatura ambiente\u00a0<strong>quando n\u00e3o estiverem em uso<\/strong>\u00a0.\u00a0Deve-se notar que nunca foi poss\u00edvel aquecer os cristais de Ge (Li), pois o l\u00edtio flutuava para fora do cristal, arruinando o detector.<\/p>\n<p>Tornaram-se dispon\u00edveis sistemas comerciais que utilizam\u00a0<strong>t\u00e9cnicas avan\u00e7adas de refrigera\u00e7\u00e3o<\/strong>\u00a0(por exemplo, um\u00a0\u00a0<strong>resfriador de tubo de pulso<\/strong>\u00a0) para eliminar a necessidade de resfriamento com nitrog\u00eanio l\u00edquido.\u00a0Este sistema de refrigera\u00e7\u00e3o \u00e9 um criostato el\u00e9trico,\u00a0<strong>completamente\u00a0livre de\u00a0LN\u00a0<sub>2<\/sub><\/strong>\u00a0.<\/p>\n<p>Veja tamb\u00e9m: Detectores de germ\u00e2nio, MIRION Technologies.\u00a0&lt;dispon\u00edvel em: https:\/\/www.mirion.com\/products\/germanium-detectors&gt;.<\/p>\n<h2>Detector HPGe &#8211; Princ\u00edpio de opera\u00e7\u00e3o<\/h2>\n<p>A opera\u00e7\u00e3o dos detectores de semicondutores \u00e9 resumida nos seguintes pontos:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/ionizing-radiation\/\">A radia\u00e7\u00e3o ionizante<\/a>\u00a0entra no volume sens\u00edvel (\u00a0<strong>cristal de germ\u00e2nio<\/strong>\u00a0) do detector e interage com o material semicondutor.<\/li>\n<li>O f\u00f3ton de alta energia que passa pelo detector ioniza os \u00e1tomos do semicondutor, produzindo os\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/electron-hole-pair\/\">pares el\u00e9tron-buraco<\/a>\u00a0.\u00a0O n\u00famero de pares el\u00e9tron-buraco \u00e9 proporcional \u00e0 energia da radia\u00e7\u00e3o para o semicondutor.\u00a0Como resultado, um n\u00famero de el\u00e9trons \u00e9 transferido da banda de val\u00eancia para a banda de condu\u00e7\u00e3o e um n\u00famero igual de orif\u00edcios \u00e9 criado na banda de val\u00eancia.<\/li>\n<li>Como o germ\u00e2nio pode ter uma espessura sens\u00edvel e esgotada de cent\u00edmetros, eles s\u00e3o capazes de\u00a0<strong>absorver totalmente os f\u00f3tons de alta energia<\/strong>\u00a0\u00a0(at\u00e9 alguns MeV).<\/li>\n<li>Sob a influ\u00eancia de um campo el\u00e9trico, el\u00e9trons e buracos viajam para os eletrodos, onde resultam em um pulso que pode ser medido em um circuito externo.<\/li>\n<li>Esse pulso carrega informa\u00e7\u00f5es sobre a energia da radia\u00e7\u00e3o incidente original.\u00a0O n\u00famero desses pulsos por unidade de tempo tamb\u00e9m fornece informa\u00e7\u00f5es sobre a intensidade da radia\u00e7\u00e3o.<\/li>\n<\/ul>\n<p>Em todos os casos, um f\u00f3ton deposita uma parte de sua energia ao longo do caminho e pode ser absorvido totalmente.\u00a0A absor\u00e7\u00e3o total de um f\u00f3ton de 1 MeV produz cerca de 3 x 10\u00a0<sup>5<\/sup>\u00a0pares de furos de el\u00e9trons.\u00a0Este valor \u00e9 menor em compara\u00e7\u00e3o com o n\u00famero total de portadores livres em de 1 cm\u00a0<sup>3\u00a0<\/sup><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/intrinsic-semiconductor-pure-semiconductor\/\">semicondutor intr\u00ednseco<\/a>\u00a0.\u00a0As part\u00edculas que passam pelo detector ionizam os \u00e1tomos do semicondutor, produzindo os pares el\u00e9tron-buraco.\u00a0Mas em detectores \u00e0 base de germ\u00e2nio \u00e0 temperatura ambiente,\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/optical-and-thermal-excitation\/\"><strong>a excita\u00e7\u00e3o t\u00e9rmica<\/strong><\/a>\u00a0\u00e9 dominante.\u00a0\u00c9 causada por impurezas, irregularidade na estrutura ou\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/what-is-dopant-in-semiconductors\/\">dopante<\/a>\u00a0.\u00a0Depende fortemente da\u00a0<sub>diferen\u00e7a<\/sub>\u00a0E(uma dist\u00e2ncia entre a val\u00eancia e a banda de condu\u00e7\u00e3o), que \u00e9 muito baixa para o germ\u00e2nio (Egap = 0,67 eV).\u00a0Como a excita\u00e7\u00e3o t\u00e9rmica resulta no ru\u00eddo do detector, \u00e9 necess\u00e1rio um resfriamento ativo para alguns tipos de semicondutores (por exemplo, germ\u00e2nio).<\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/germanium-semiconductor-energy-gap.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-26568 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/germanium-semiconductor-energy-gap-300x207.png\" alt=\"Germ\u00e2nio - semicondutor\" width=\"300\" height=\"207\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/germanium-semiconductor-energy-gap-300x207.png\" \/><\/a>Observe que uma\u00a0amostra de\u00a01 cm\u00a0<sup>3<\/sup>\u00a0de germ\u00e2nio puro a 20 \u00b0 C cont\u00e9m cerca de 4,2 \u00d7 10\u00a0<sup>22<\/sup>\u00a0\u00e1tomos, mas tamb\u00e9m cont\u00e9m cerca de 2,5 x 10\u00a0<sup>13<\/sup>\u00a0el\u00e9trons livres e 2,5 x 10\u00a0<sup>13<\/sup>\u00a0orif\u00edcios gerados constantemente a partir da energia t\u00e9rmica.\u00a0Como pode ser visto, a rela\u00e7\u00e3o sinal-ru\u00eddo (S \/ N) seria m\u00ednima (comparar com 3 x 10\u00a0<sup>5<\/sup>\u00a0pares de electr\u00e3o-lacuna).\u00a0A adi\u00e7\u00e3o de 0,001% de ars\u00eanico (uma impureza) doa um extra de 10\u00a0<sup>17<\/sup>el\u00e9trons livres no mesmo volume e a condutividade el\u00e9trica \u00e9 aumentada em um fator de 10.000.\u00a0No material dopado, a rela\u00e7\u00e3o sinal \/ ru\u00eddo (S \/ N) seria ainda menor.\u00a0Como o germ\u00e2nio possui um intervalo de banda relativamente baixo, esses detectores devem ser resfriados para reduzir a gera\u00e7\u00e3o t\u00e9rmica de portadores de carga (portanto, reverter a corrente de fuga) para um n\u00edvel aceit\u00e1vel.\u00a0Caso contr\u00e1rio, o ru\u00eddo induzido pela corrente de fuga destr\u00f3i a resolu\u00e7\u00e3o de energia do detector.<\/p>\n<h3>Jun\u00e7\u00e3o polarizada inversa<\/h3>\n<p>O detector de semicondutores opera muito melhor como detector de radia\u00e7\u00e3o se uma tens\u00e3o externa for aplicada atrav\u00e9s da jun\u00e7\u00e3o na\u00a0<strong>dire\u00e7\u00e3o inversa<\/strong>\u00a0.\u00a0A\u00a0<strong>regi\u00e3o de deple\u00e7\u00e3o<\/strong>\u00a0funcionar\u00e1 como um detector de radia\u00e7\u00e3o.\u00a0A melhoria pode ser alcan\u00e7ada pelo uso de uma tens\u00e3o de polariza\u00e7\u00e3o reversa na\u00a0<strong>jun\u00e7\u00e3o PN<\/strong>esgotar o detector de portadores livres, que \u00e9 o princ\u00edpio da maioria dos detectores de semicondutores.\u00a0A polariza\u00e7\u00e3o reversa de uma jun\u00e7\u00e3o aumenta a espessura da regi\u00e3o de deple\u00e7\u00e3o porque a diferen\u00e7a de potencial entre a jun\u00e7\u00e3o \u00e9 aprimorada.\u00a0Os detectores de germ\u00e2nio possuem uma estrutura de pinos na qual a regi\u00e3o intr\u00ednseca (i) \u00e9 sens\u00edvel \u00e0 radia\u00e7\u00e3o ionizante, particularmente os raios X e raios gama.\u00a0Sob polariza\u00e7\u00e3o reversa, um campo el\u00e9trico se estende pela regi\u00e3o intr\u00ednseca ou esgotada.\u00a0Nesse caso, a tens\u00e3o negativa \u00e9 aplicada no lado p e positiva no segundo.\u00a0Os furos na regi\u00e3o p s\u00e3o atra\u00eddos da jun\u00e7\u00e3o em dire\u00e7\u00e3o ao contato p e da mesma forma para os el\u00e9trons e o contato n.\u00a0Essa carga, que \u00e9 proporcional \u00e0 energia depositada no detector pelo f\u00f3ton recebido,<\/p>\n<p>Veja tamb\u00e9m: Detectores de germ\u00e2nio, MIRION Technologies.\u00a0&lt;dispon\u00edvel em: https:\/\/www.mirion.com\/products\/germanium-detectors&gt;.<\/p>\n<h2>Aplica\u00e7\u00e3o de detectores de germ\u00e2nio &#8211; espectroscopia gama<\/h2>\n<p>Como foi escrito, o estudo e a an\u00e1lise de espectros de raios gama para uso cient\u00edfico e t\u00e9cnico s\u00e3o chamados espectroscopia gama, e os espectr\u00f4metros de raios gama s\u00e3o os instrumentos que observam e coletam esses dados.\u00a0Um espectr\u00f4metro de raios gama (GRS) \u00e9 um dispositivo sofisticado para medir a distribui\u00e7\u00e3o de energia da radia\u00e7\u00e3o gama.\u00a0Para a medi\u00e7\u00e3o de raios gama acima de v\u00e1rias centenas de keV, existem duas categorias de detectores de grande import\u00e2ncia:\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/scintillation-counter-scintillation-detector\/naitl-scintillators\/\"><strong>cintiladores inorg\u00e2nicos como NaI (Tl)<\/strong><\/a>\u00a0\u00a0e\u00a0\u00a0<strong>detectores semicondutores<\/strong>.\u00a0Nos artigos anteriores, descrevemos a espectroscopia gama usando um detector de cintila\u00e7\u00e3o, que consiste em um cristal cintilador adequado, um tubo fotomultiplicador e um circuito para medir a altura dos pulsos produzidos pelo fotomultiplicador.\u00a0As vantagens de um contador de cintila\u00e7\u00e3o s\u00e3o sua efici\u00eancia (tamanho grande e alta densidade) e as altas taxas de precis\u00e3o e contagem poss\u00edveis.\u00a0Devido ao alto n\u00famero at\u00f4mico de iodo, um grande n\u00famero de todas as intera\u00e7\u00f5es resultar\u00e1 na absor\u00e7\u00e3o completa da energia dos raios gama, de modo que a fra\u00e7\u00e3o fotogr\u00e1fica ser\u00e1 alta.<\/p>\n<figure id=\"attachment_26113\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26113\"><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\"><img loading=\"lazy\" class=\"wp-image-26113 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\" alt=\"Espectro do detector HPGe\" width=\"331\" height=\"276\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\" \/><\/a><figcaption id=\"caption-attachment-26113\" class=\"wp-caption-text\">Figura: Legenda: Compara\u00e7\u00e3o dos espectros de NaI (Tl) e HPGe para o cobalto-60.\u00a0Fonte: Radiois\u00f3topos e metodologia de radia\u00e7\u00e3o I, II.\u00a0Soo Hyun Byun, notas de aula.\u00a0Universidade McMaster, Canad\u00e1.<\/figcaption><\/figure>\n<p>Mas, se\u00a0\u00a0for necess\u00e1ria\u00a0uma\u00a0\u00a0<strong>resolu\u00e7\u00e3o perfeita de energia<\/strong>\u00a0, precisamos usar\u00a0\u00a0<strong>um detector \u00e0 base de germ\u00e2nio<\/strong>\u00a0, como o\u00a0\u00a0<strong>detector HPGe<\/strong>\u00a0.\u00a0Os detectores de semicondutores \u00e0 base de germ\u00e2nio s\u00e3o mais comumente usados \u200b\u200bonde \u00e9 necess\u00e1ria uma resolu\u00e7\u00e3o de energia muito boa, especialmente para\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\"><strong>espectroscopia gama<\/strong><\/a>\u00a0, bem como\u00a0\u00a0<strong>espectroscopia de raios-x<\/strong>.\u00a0Na espectroscopia gama, o germ\u00e2nio \u00e9 preferido devido ao seu n\u00famero at\u00f4mico ser muito maior que o sil\u00edcio e aumentar a probabilidade de intera\u00e7\u00e3o com raios gama.\u00a0Al\u00e9m disso, o germ\u00e2nio possui menor energia m\u00e9dia necess\u00e1ria para criar um par de el\u00e9trons-orif\u00edcios, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.\u00a0Isso tamb\u00e9m fornece ao \u00faltimo uma melhor resolu\u00e7\u00e3o em energia.\u00a0O FWHM (largura total na metade do m\u00e1ximo) para detectores de germ\u00e2nio \u00e9 uma fun\u00e7\u00e3o da energia.\u00a0Para um f\u00f3ton de 1,3 MeV, o FWHM \u00e9 de 2,1 keV, o que \u00e9 muito baixo.<\/p>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Detectores germ\u00e2nio hiper-puro (detectores HPGe) s\u00e3o a melhor solu\u00e7\u00e3o para espectroscopia precisa de raios gama e raios-x. Os detectores HPGe devem operar a temperaturas muito baixas de nitrog\u00eanio l\u00edquido. Dosimetria de Radia\u00e7\u00e3o Detector HPGe com criostato LN2 Fonte: canberra.com Detectores germ\u00e2nio hiper-puro\u00a0(\u00a0detectores\u00a0HPGe\u00a0) s\u00e3o a melhor solu\u00e7\u00e3o para\u00a0espectroscopia\u00a0precisa de\u00a0raios gama e raios-x\u00a0.\u00a0Em compara\u00e7\u00e3o com os\u00a0detectores de &#8230; <a title=\"Detector germ\u00e2nio hiper-puro &#8211; HPGe\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/\" aria-label=\"More on Detector germ\u00e2nio hiper-puro &#8211; HPGe\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Detector germ\u00e2nio hiper-puro - HPGe - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"Detectores germ\u00e2nio hiper-puro (detectores HPGe) s\u00e3o a melhor solu\u00e7\u00e3o para espectroscopia precisa de raios gama e raios-x. Os detectores HPGe devem operar a temperaturas muito baixas de nitrog\u00eanio l\u00edquido. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Detector germ\u00e2nio hiper-puro - HPGe - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"Detectores germ\u00e2nio hiper-puro (detectores HPGe) s\u00e3o a melhor solu\u00e7\u00e3o para espectroscopia precisa de raios gama e raios-x. Os detectores HPGe devem operar a temperaturas muito baixas de nitrog\u00eanio l\u00edquido. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-21T11:51:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-07-03T07:56:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"9 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"http:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/\",\"name\":\"Detector germ\\u00e2nio hiper-puro - HPGe - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/#primaryimage\"},\"datePublished\":\"2020-07-21T11:51:39+00:00\",\"dateModified\":\"2021-07-03T07:56:49+00:00\",\"author\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Detectores germ\\u00e2nio hiper-puro (detectores HPGe) s\\u00e3o a melhor solu\\u00e7\\u00e3o para espectroscopia precisa de raios gama e raios-x. Os detectores HPGe devem operar a temperaturas muito baixas de nitrog\\u00eanio l\\u00edquido. Dosimetria de Radia\\u00e7\\u00e3o\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/detector-de-germanio-de-alta-pureza-hpge-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/21702"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=21702"}],"version-history":[{"count":1,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/21702\/revisions"}],"predecessor-version":[{"id":23133,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/21702\/revisions\/23133"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=21702"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=21702"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=21702"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}