{"id":21572,"date":"2020-07-20T11:32:31","date_gmt":"2020-07-20T11:32:31","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/"},"modified":"2020-07-20T11:33:39","modified_gmt":"2020-07-20T11:33:39","slug":"o-que-e-um-dosimetro-termoluminescente-tld-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/","title":{"rendered":"O que \u00e9 um dos\u00edmetro termoluminescente &#8211; TLD &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Um dos\u00edmetro termoluminescente, abreviado como TLD, \u00e9 um dos\u00edmetro de radia\u00e7\u00e3o passiva, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante medindo a intensidade da luz vis\u00edvel emitida por um cristal sens\u00edvel no detector quando o cristal \u00e9 aquecido.\u00a0Dosimetria de Radia\u00e7\u00e3o<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p>Um\u00a0<strong>dos\u00edmetro termoluminescente<\/strong>\u00a0, abreviado como\u00a0<strong>TLD<\/strong>\u00a0, \u00e9 um\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-dosimetry\/radiation-dosimeter\/active-dosimeters-passive-dosimeters\/\">dos\u00edmetro de radia\u00e7\u00e3o passiva<\/a>\u00a0, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante medindo a intensidade da luz vis\u00edvel emitida por um\u00a0<strong>cristal sens\u00edvel<\/strong>\u00a0no detector quando o cristal \u00e9\u00a0<strong>aquecido<\/strong>\u00a0.\u00a0A intensidade da luz emitida \u00e9 medida pelo\u00a0<strong>leitor de DPN<\/strong>\u00a0e depende da\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/radiation-exposure\/\">exposi\u00e7\u00e3o<\/a>\u00a0\u00e0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/radiation-exposure\/\">radia\u00e7\u00e3o<\/a>\u00a0.\u00a0<strong>Dos\u00edmetros termoluminescentes<\/strong>foi inventado em 1954 pelo professor Farrington Daniels da Universidade de Wisconsin-Madison. Os dos\u00edmetros TLD s\u00e3o aplic\u00e1veis \u200b\u200ba situa\u00e7\u00f5es em que informa\u00e7\u00f5es em tempo real n\u00e3o s\u00e3o necess\u00e1rias, mas registros precisos de monitoramento de doses acumuladas s\u00e3o desejados para compara\u00e7\u00e3o com medi\u00e7\u00f5es em campo ou para avaliar o potencial de efeitos \u00e0 sa\u00fade a longo prazo. Na dosimetria, os tipos de crach\u00e1 de fibra de quartzo e filme est\u00e3o sendo substitu\u00eddos por TLDs e EPDs (Electronic Personal Dosimeter).<\/p>\n<h2><span>TLD &#8211; Princ\u00edpio de Opera\u00e7\u00e3o<\/span><\/h2>\n<p><span>A seguinte vis\u00e3o geral b\u00e1sica explica\u00a0<\/span><strong><span>como um TLD funciona<\/span><\/strong><span>\u00a0:<\/span><\/p>\n<ol>\n<li><span>Quando a radia\u00e7\u00e3o ionizante passa pelo detector (chip), o chip absorve a radia\u00e7\u00e3o e sua estrutura muda levemente.<\/span><\/li>\n<li><span>Em materiais termoluminescentes, os\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/what-is-electron-properties-of-electron\/\"><span>el\u00e9trons<\/span><\/a><span>\u00a0podem alcan\u00e7ar a banda de condu\u00e7\u00e3o, quando s\u00e3o excitados, por exemplo, por\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/ionizing-radiation\/\"><span>radia\u00e7\u00e3o ionizante<\/span><\/a><span>\u00a0(isto \u00e9, devem obter energia maior que o\u00a0<\/span><sub><span>intervalo<\/span><\/sub><span>\u00a0E\u00a0).\u00a0Mas, neste caso, existem defeitos no material ou impurezas s\u00e3o adicionadas para prender el\u00e9trons no intervalo da banda e mant\u00ea-los l\u00e1.<\/span><\/li>\n<li><span>Esses el\u00e9trons presos representam energia armazenada pelo tempo em que os el\u00e9trons s\u00e3o retidos e a quantidade dessa energia depende da exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o.<\/span><\/li>\n<li><span>Para obter a dose recebida, o\u00a0<\/span><strong><span>chip<\/span><\/strong><span>\u00a0do\u00a0<strong>TLD<\/strong>\u00a0deve ser aquecido neste\u00a0<\/span><strong><span>leitor de TLD<\/span><\/strong><span>\u00a0.\u00a0Os el\u00e9trons presos retornam ao estado fundamental e emitem f\u00f3tons de luz vis\u00edvel.\u00a0A quantidade de luz emitida em rela\u00e7\u00e3o \u00e0 temperatura \u00e9 chamada de\u00a0<\/span><strong><span>curva de brilho<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<li><span>Ap\u00f3s a conclus\u00e3o da leitura, o\u00a0<\/span><strong><span>TLD \u00e9 recozido<\/span><\/strong><span>\u00a0em alta temperatura.\u00a0Esse processo zera essencialmente o material TL, liberando todos os el\u00e9trons presos.\u00a0O TLD est\u00e1\u00a0<\/span><strong><span>pronto para reutiliza\u00e7\u00e3o<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<\/ol>\n<h3><span>Leitor de TLD<\/span><\/h3>\n<p><span>Como foi escrito, a energia anteriormente absorvida da radia\u00e7\u00e3o eletromagn\u00e9tica ou outra radia\u00e7\u00e3o ionizante nesses materiais \u00e9 reemitida como luz ap\u00f3s o aquecimento do material.\u00a0A intensidade da luz emitida \u00e9 medida pelo leitor de DPN e depende da exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o.\u00a0Um\u00a0<\/span><strong><span>leitor de TLD<\/span><\/strong><span>\u00a0b\u00e1sico t\u00edpico\u00a0cont\u00e9m os seguintes componentes:<\/span><\/p>\n<ul>\n<li><strong><span>Aquecedor<\/span><\/strong><span>\u00a0.\u00a0Aquecedor aumenta a temperatura do material TL<\/span><\/li>\n<li><strong><span>Tubo fotomultiplicador<\/span><\/strong><span>\u00a0.\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/scintillation-counter-scintillation-detector\/photomultiplier-tube-pmt\/\"><span>O PMT<\/span><\/a><span>\u00a0amplifica e mede a sa\u00edda de luz.<\/span><\/li>\n<li><strong><span>Medidor \/ Gravador<\/span><\/strong><span>\u00a0.\u00a0O gravador \u00e9 capaz de exibir e gravar dados.<\/span><\/li>\n<\/ul>\n<figure id=\"attachment_26943\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-26943\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Glow-Curve-TLD-Reader.png\"><img loading=\"lazy\" class=\"wp-image-26943 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Glow-Curve-TLD-Reader.png\" alt=\"Curva de brilho - Leitor de TLD\" width=\"309\" height=\"212\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Glow-Curve-TLD-Reader.png\" \/><\/a><figcaption id=\"caption-attachment-26943\" class=\"wp-caption-text\"><span>Fonte da curva de brilho: Dosimetria.\u00a0Guia de Estudo para T\u00e9cnico em Controle Radiol\u00f3gico.\u00a0DOE-HDBK-1122-99.\u00a0Departamento de Energia<\/span><\/figcaption><\/figure>\n<p><span>Para obter a dose recebida, o chip do TLD deve ser aquecido neste leitor de TLD.\u00a0Os el\u00e9trons presos retornam ao estado fundamental e emitem f\u00f3tons de luz vis\u00edvel.\u00a0A quantidade de luz emitida em rela\u00e7\u00e3o \u00e0 temperatura \u00e9 chamada de\u00a0<\/span><strong><span>curva de brilho<\/span><\/strong><span>\u00a0.\u00a0Esta curva \u00e9 analisada para determinar a dose.\u00a0Ap\u00f3s a conclus\u00e3o da leitura, o TLD \u00e9 recozido em alta temperatura.\u00a0Esse processo zera essencialmente o material TL, liberando todos os el\u00e9trons presos.\u00a0O TLD est\u00e1 pronto para reutiliza\u00e7\u00e3o.\u00a0Existem dois tipos de leitores.\u00a0Leitores autom\u00e1ticos e manuais.\u00a0O leitor autom\u00e1tico de TLD \u00e9 muito mais complicado do que se poderia esperar.<\/span><\/p>\n<h2><span>Vantagens e desvantagens dos TLDs<\/span><\/h2>\n<h3><span>Vantagens dos TLDs<\/span><\/h3>\n<ul>\n<li><span>Os DPNs podem medir uma\u00a0<\/span><strong><span>gama maior de doses<\/span><\/strong><span>\u00a0em compara\u00e7\u00e3o com os emblemas dos filmes.<\/span><\/li>\n<li><span>Doses de TLDs podem ser facilmente obtidas.<\/span><\/li>\n<li><span>Os TLDs podem ser lidos no local em vez de serem enviados para desenvolvimento.<\/span><\/li>\n<li><span>Os TLDs s\u00e3o\u00a0<\/span><strong><span>facilmente reutiliz\u00e1veis<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<\/ul>\n<h3><span>Desvantagens dos TLDs<\/span><\/h3>\n<ul>\n<li><span>Cada dose n\u00e3o pode ser lida mais de uma vez.<\/span><\/li>\n<li><span>O processo de leitura efetivamente zera o TLD.<\/span><\/li>\n<\/ul>\n<h2><span>Dos\u00edmetro Termoluminescente de N\u00eautrons &#8211; TLD de N\u00eautrons<\/span><\/h2>\n<p><span>A\u00a0<\/span><strong><span>dosimetria de n\u00eautrons de pessoal<\/span><\/strong><span>\u00a0continua sendo um dos problemas no campo da prote\u00e7\u00e3o contra radia\u00e7\u00e3o, pois nenhum m\u00e9todo isolado fornece a combina\u00e7\u00e3o de resposta de energia, sensibilidade, caracter\u00edsticas de depend\u00eancia de orienta\u00e7\u00e3o e precis\u00e3o necess\u00e1rias para atender \u00e0s necessidades de um dos\u00edmetro de pessoal.<\/span><\/p>\n<p><span>Os dos\u00edmetros pessoais de n\u00eautrons mais utilizados para fins de prote\u00e7\u00e3o contra radia\u00e7\u00e3o s\u00e3o os\u00a0<\/span><strong><span>dos\u00edmetros termoluminescentes<\/span><\/strong><span>\u00a0e os\u00a0<\/span><strong><span>albedo<\/span><\/strong><span>\u00a0.\u00a0Ambos s\u00e3o baseados neste fen\u00f4meno &#8211;\u00a0<\/span><strong><span>termoluminesc\u00eancia<\/span><\/strong><span>\u00a0.\u00a0Para esse fim, o fluoreto de l\u00edtio (\u00a0<\/span><strong><span>LiF<\/span><\/strong><span>\u00a0) como material sens\u00edvel (chip) \u00e9 amplamente utilizado.\u00a0<\/span><strong><span>TLD de fluoreto de l\u00edtio<\/span><\/strong><span>\u00e9 usado para exposi\u00e7\u00e3o a gama e n\u00eautrons (indiretamente, usando a rea\u00e7\u00e3o nuclear Li-6 (n, alfa)).\u00a0Pequenos cristais de LiF (fluoreto de l\u00edtio) s\u00e3o os dos\u00edmetros de DPN mais comuns, pois possuem as mesmas propriedades de absor\u00e7\u00e3o dos tecidos moles.\u00a0O l\u00edtio possui dois is\u00f3topos est\u00e1veis, l\u00edtio-6 (7,4%) e l\u00edtio-7 (92,6%).\u00a0Li-6 \u00e9 o is\u00f3topo sens\u00edvel aos n\u00eautrons.\u00a0Para registrar n\u00eautrons, os dos\u00edmetros de cristal LiF podem ser enriquecidos em l\u00edtio-6 para melhorar a rea\u00e7\u00e3o nuclear de l\u00edtio-6 (n, alfa).\u00a0A efici\u00eancia do detector depende da\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/neutron\/neutron-energy\/\"><span>energia dos n\u00eautrons<\/span><\/a><span>.\u00a0Como a intera\u00e7\u00e3o dos n\u00eautrons com qualquer elemento \u00e9 altamente dependente da energia, \u00e9 muito dif\u00edcil tornar um dos\u00edmetro independente da energia dos n\u00eautrons.\u00a0Para separar n\u00eautrons t\u00e9rmicos e f\u00f3tons, os dos\u00edmetros de LiF s\u00e3o mais utilizados, contendo diferentes porcentagens de l\u00edtio-6.\u00a0Chip LiF enriquecido em l\u00edtio-6, que \u00e9 muito sens\u00edvel aos n\u00eautrons t\u00e9rmicos e chip LiF contendo muito pouco de l\u00edtio-6, que tem uma resposta desprez\u00edvel a n\u00eautrons.<\/span><\/p>\n<p><span>O princ\u00edpio dos TLDs de n\u00eautrons \u00e9 ent\u00e3o semelhante ao dos TLDs de radia\u00e7\u00e3o gama.\u00a0No chip LiF, existem impurezas (por exemplo, mangan\u00eas ou magn\u00e9sio), que produzem estados de armadilha para el\u00e9trons energ\u00e9ticos.\u00a0A impureza causa armadilhas na rede cristalina onde, ap\u00f3s a irradia\u00e7\u00e3o (\u00e0 radia\u00e7\u00e3o alfa), os el\u00e9trons s\u00e3o mantidos.\u00a0Quando o cristal \u00e9 aquecido, os el\u00e9trons presos s\u00e3o liberados e a luz \u00e9 emitida.\u00a0A quantidade de luz est\u00e1 relacionada \u00e0 dose de radia\u00e7\u00e3o recebida pelo cristal.<\/span><\/p>\n<h3><span>Dos\u00edmetro termoluminescente de n\u00eautrons de Albedo<\/span><\/h3>\n<p><strong><span>A dosimetria de n\u00eautrons de Albedo<\/span><\/strong><span>\u00a0baseia-se no efeito da modera\u00e7\u00e3o e retroespalhamento dos n\u00eautrons pelo corpo humano.\u00a0Albedo, a palavra latina para &#8220;brancura&#8221;, foi definida por Lambert como a fra\u00e7\u00e3o da luz incidente refletida difusamente por uma superf\u00edcie.\u00a0A modera\u00e7\u00e3o e a retroespalhamento de n\u00eautrons pelo corpo humano cria um fluxo de n\u00eautrons na superf\u00edcie do corpo na faixa de energia t\u00e9rmica e intermedi\u00e1ria.\u00a0Esses n\u00eautrons retroespalhados, chamados n\u00eautrons\u00a0<\/span><strong><span>albedo<\/span><\/strong><span>\u00a0, podem ser detectados por um dos\u00edmetro (geralmente um\u00a0<\/span><strong><span>chip LiF TLD<\/span><\/strong><span>\u00a0), colocado no corpo, projetado para\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/neutron\/detection-neutrons\/thermal-neutrons-detection\/\"><span>detectar n\u00eautrons t\u00e9rmicos<\/span><\/a><span>\u00a0.\u00a0<\/span><strong><span>Dos\u00edmetros de Albedo<\/span><\/strong><span>Verificou-se que s\u00e3o os \u00fanicos dos\u00edmetros que podem medir doses devido a n\u00eautrons em toda a gama de energias.\u00a0Normalmente, dois tipos de fluoreto de l\u00edtio s\u00e3o usados \u200b\u200bpara separar doses contribu\u00eddas por raios gama e n\u00eautrons.\u00a0Chip LiF enriquecido em l\u00edtio-6, que \u00e9 muito sens\u00edvel a n\u00eautrons t\u00e9rmicos e chip LiF contendo muito pouco de l\u00edtio-6, que tem uma resposta desprez\u00edvel a n\u00eautrons.<\/span><\/p>\n<h2><span>Medi\u00e7\u00e3o e monitoramento de doses de radia\u00e7\u00e3o<\/span><\/h2>\n<p><span>Nos cap\u00edtulos anteriores, descrevemos a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-equivalente-definicao\/\"><span>dose equivalente<\/span><\/a><span>\u00a0e a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva<\/span><\/a><span>\u00a0.\u00a0Mas essas doses\u00a0<\/span><strong><span>n\u00e3o<\/span><\/strong><span>\u00a0s\u00e3o\u00a0<strong>diretamente mensur\u00e1veis<\/strong>\u00a0.\u00a0Para esse fim, o ICRP introduziu e definiu um conjunto de\u00a0<\/span><strong><span>quantidades operacionais<\/span><\/strong><span>\u00a0, que podem ser medidas e cujo objetivo \u00e9 fornecer uma estimativa razo\u00e1vel para as quantidades de prote\u00e7\u00e3o.\u00a0Essas quantidades visam fornecer uma\u00a0<\/span><strong><span>estimativa conservadora<\/span><\/strong><span>\u00a0do valor das quantidades de prote\u00e7\u00e3o relacionadas a uma exposi\u00e7\u00e3o, evitando subestima\u00e7\u00e3o e superestima\u00e7\u00e3o demais.<\/span><\/p>\n<p><span>Os links num\u00e9ricos entre essas quantidades s\u00e3o representados por\u00a0<\/span><strong><span>coeficientes de convers\u00e3o<\/span><\/strong><span>\u00a0, definidos para uma pessoa de refer\u00eancia.\u00a0\u00c9 muito importante que um conjunto de coeficientes de convers\u00e3o acordado internacionalmente esteja dispon\u00edvel para uso geral nas pr\u00e1ticas de prote\u00e7\u00e3o radiol\u00f3gica para exposi\u00e7\u00f5es ocupacionais e exposi\u00e7\u00f5es do p\u00fablico.\u00a0Para o c\u00e1lculo dos coeficientes de convers\u00e3o para exposi\u00e7\u00e3o externa, fantasmas computacionais s\u00e3o usados \u200b\u200bpara avalia\u00e7\u00e3o da dose em v\u00e1rios campos de radia\u00e7\u00e3o.\u00a0Para o c\u00e1lculo dos coeficientes de dose da ingest\u00e3o de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/radionuclide-radioisotope\/\"><span>radionucl\u00eddeos<\/span><\/a><span>\u00a0, s\u00e3o utilizados modelos biokin\u00e9ticos para radionucl\u00eddeos, dados fisiol\u00f3gicos de refer\u00eancia e fantasmas computacionais.<\/span><\/p>\n<p><span>Um conjunto de dados avaliados de coeficientes de convers\u00e3o para prote\u00e7\u00e3o e quantidades operacionais para exposi\u00e7\u00e3o externa a f\u00f3ton monoenerg\u00e9tico, n\u00eautrons e radia\u00e7\u00e3o de el\u00e9trons sob condi\u00e7\u00f5es espec\u00edficas de irradia\u00e7\u00e3o \u00e9 publicado em relat\u00f3rios (ICRP, 1996b, ICRU, 1997).<\/span><\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\"><img loading=\"lazy\" class=\"alignright wp-image-25488 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\" alt=\"Monitoramento de dose de radia\u00e7\u00e3o - quantidades operacionais\" width=\"500\" height=\"156\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\" \/><\/a><span>Em geral, o ICRP define quantidades operacionais para\u00a0<strong>monitoramento individual<\/strong>\u00a0e de\u00a0<\/span><strong><span>\u00e1rea<\/span><\/strong><span>\u00a0de exposi\u00e7\u00f5es externas.\u00a0As quantidades operacionais para o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/area-monitoring\/\"><strong>monitoramento da \u00e1rea<\/strong><\/a>\u00a0s\u00e3o:<\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/ambient-dose-equivalent\/\"><strong><span>Dose ambiente equivalente<\/span><\/strong><\/a><span>\u00a0, H * (10).\u00a0O equivalente \u00e0 dose ambiente \u00e9 uma quantidade operacional para o monitoramento da \u00e1rea de radia\u00e7\u00e3o fortemente penetrante.<\/span><\/li>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/directional-dose-equivalent\/\"><strong><span>Dose direcional equivalente<\/span><\/strong><\/a><span>\u00a0, H &#8216;(d, \u03a9).\u00a0A dose direcional equivalente \u00e9 uma quantidade operacional para o monitoramento da \u00e1rea de radia\u00e7\u00e3o que penetra fracamente.<\/span><\/li>\n<\/ul>\n<p><span>As quantidades operacionais para\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/individual-monitoring\/\"><strong><span>monitoramento individual<\/span><\/strong><\/a><span>\u00a0s\u00e3o:<\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/personal-dose-equivalent\/\"><strong><span>Dose equivalente pessoal<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><\/a><span>\u00a0.\u00a0O<\/span><strong><span>\u00a0H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><span>\u00a0dose equivalente \u00e9 uma quantidade operacional para monitoriza\u00e7\u00e3o individual para a avalia\u00e7\u00e3o da dose para a pele e para as m\u00e3os e os p\u00e9s.<\/span><\/li>\n<li><strong><span>Dose equivalente pessoal<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0.\u00a0O\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0de dose equivalente \u00e9 uma quantidade operacional para monitoriza\u00e7\u00e3o individual para a avalia\u00e7\u00e3o da dose eficaz.<\/span><\/li>\n<\/ul>\n<p><span>Refer\u00eancia especial: ICRP, 2007. Recomenda\u00e7\u00f5es de 2007 da Comiss\u00e3o Internacional de Prote\u00e7\u00e3o Radiol\u00f3gica.\u00a0Publica\u00e7\u00e3o 103 da ICRP. Ann.\u00a0ICRP 37 (2-4).<\/span><\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min.png\"><img loading=\"lazy\" class=\"aligncenter size-large wp-image-25493 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" alt=\"Medi\u00e7\u00e3o e monitoramento de radia\u00e7\u00e3o - quantidades e limites\" width=\"1024\" height=\"600\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h3><span>Limites de dose<\/span><\/h3>\n<p><span>Veja tamb\u00e9m:\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-limite-de-dose-radiacao-definicao\/\"><span>Limites de dose<\/span><\/a><\/p>\n<p><span>Os limites de dose s\u00e3o divididos em dois grupos, o p\u00fablico e os trabalhadores expostos ocupacionalmente.\u00a0De acordo com o ICRP, a exposi\u00e7\u00e3o ocupacional refere-se a toda a exposi\u00e7\u00e3o incorrida pelos trabalhadores no curso de seu trabalho, com exce\u00e7\u00e3o da<\/span><\/p>\n<ol>\n<li><span>exposi\u00e7\u00f5es exclu\u00eddas e exposi\u00e7\u00f5es de atividades isentas que envolvam radia\u00e7\u00e3o ou fontes isentas<\/span><\/li>\n<li><span>qualquer exposi\u00e7\u00e3o m\u00e9dica<\/span><\/li>\n<li><span>a radia\u00e7\u00e3o natural local normal de fundo.<\/span><\/li>\n<\/ol>\n<p><span>A tabela a seguir resume os limites de dose para trabalhadores expostos ocupacionalmente e para o p\u00fablico:<\/span><\/p>\n<figure id=\"attachment_25487\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-25487\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\"><img loading=\"lazy\" class=\"size-full wp-image-25487 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\" alt=\"limites de dose - radia\u00e7\u00e3o\" width=\"628\" height=\"207\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\" \/><\/a><figcaption id=\"caption-attachment-25487\" class=\"wp-caption-text\"><span>Tabela de limites de dose para trabalhadores expostos ocupacionalmente e para o p\u00fablico.<\/span><br \/>\n<span>Fonte dos dados: ICRP, 2007. Recomenda\u00e7\u00f5es de 2007 da Comiss\u00e3o Internacional de Prote\u00e7\u00e3o Radiol\u00f3gica.\u00a0Publica\u00e7\u00e3o 103 da ICRP. Ann.\u00a0ICRP 37 (2-4).<\/span><\/figcaption><\/figure>\n<p><span>De acordo com a recomenda\u00e7\u00e3o do ICRP em sua declara\u00e7\u00e3o sobre rea\u00e7\u00f5es teciduais de 21 de abril de 2011, o limite de dose equivalente para a lente do olho para exposi\u00e7\u00e3o ocupacional em situa\u00e7\u00f5es de exposi\u00e7\u00e3o planejada foi reduzido de 150 mSv \/ ano para 20 mSv \/ ano, em m\u00e9dia por per\u00edodos definidos de 5 anos, sem dose anual em um \u00fanico ano superior a 50 mSv.<\/span><\/p>\n<p><span>Os limites da\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva referem-<\/span><\/a><span>\u00a0se \u00e0 soma das doses efetivas relevantes da exposi\u00e7\u00e3o externa no per\u00edodo especificado e a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-comprometida-dose-efetiva-comprometida-definicao\/\"><span>dose efetiva comprometida<\/span><\/a><span>da ingest\u00e3o de radionucl\u00eddeos no mesmo per\u00edodo.\u00a0Para adultos, a dose efetiva comprometida \u00e9 calculada por um per\u00edodo de 50 anos ap\u00f3s a ingest\u00e3o, enquanto para crian\u00e7as \u00e9 calculada para o per\u00edodo de at\u00e9 70 anos.\u00a0O limite efetivo da dose para o corpo inteiro de 20 mSv \u00e9 um valor m\u00e9dio em cinco anos.\u00a0O limite real \u00e9 de 100 mSv em 5 anos, e n\u00e3o mais de 50 mSv em um ano.\u00a0Para esse fim, os empregadores monitoram cuidadosamente a exposi\u00e7\u00e3o desses indiv\u00edduos usando instrumentos chamados dos\u00edmetros usados \u200b\u200bem uma posi\u00e7\u00e3o do corpo representativa de sua exposi\u00e7\u00e3o.\u00a0Na maioria das situa\u00e7\u00f5es de exposi\u00e7\u00e3o ocupacional, a dose eficaz, E, pode ser derivada de quantidades operacionais usando a seguinte f\u00f3rmula:<\/span><\/p>\n<p><img loading=\"lazy\" class=\"lazy-loaded aligncenter wp-image-25528 size-full\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Occupational-Exposure-External-and-Internal-1.png\" alt=\"Exposi\u00e7\u00e3o Ocupacional - Externa e Interna.\" width=\"314\" height=\"202\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Occupational-Exposure-External-and-Internal-1.png\" data-srcset=\"\" \/><\/p>\n<h2><span>Sievert &#8211; Unidade de Dose Equivalente<\/span><\/h2>\n<p><span>Na prote\u00e7\u00e3o contra radia\u00e7\u00e3o, o\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-sievert-unidade-de-dose-equivalente-definicao\/\"><strong><span>sievert<\/span><\/strong><\/a><span>\u00a0\u00e9 uma unidade derivada de\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-equivalente-definicao\/\"><strong><span>dose equivalente<\/span><\/strong><\/a><span>\u00a0e\u00a0<\/span><strong><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva<\/span><\/a><span>\u00a0.\u00a0<\/span><\/strong><span>O sievert representa o efeito biol\u00f3gico equivalente ao dep\u00f3sito de um joule de energia de raios gama em um quilograma de tecido humano.\u00a0A unidade de sievert \u00e9 importante na prote\u00e7\u00e3o contra radia\u00e7\u00e3o e recebeu o nome do cientista sueco Rolf Sievert, que fez muitos dos primeiros trabalhos sobre dosimetria de radia\u00e7\u00e3o em terapia de radia\u00e7\u00e3o.<\/span><\/p>\n<p><span>Como foi escrito, o sievert \u00e9 usado para quantidades de dose de radia\u00e7\u00e3o, como dose equivalente e dose efetiva.\u00a0<\/span><strong><span>Dose equivalente<\/span><\/strong><span>\u00a0(s\u00edmbolo\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>T<\/span><\/sub><\/strong><strong><span>\u00a0)<\/span><\/strong><span>\u00a0\u00e9 uma quantidade de dose calculada para \u00f3rg\u00e3os individuais (\u00edndice T &#8211; tecido).\u00a0<\/span><strong><span>A dose equivalente<\/span><\/strong><span>\u00a0\u00e9 baseada na dose absorvida para um \u00f3rg\u00e3o, ajustada para levar em conta a\u00a0<\/span><strong><span>efic\u00e1cia do tipo de radia\u00e7\u00e3o<\/span><\/strong><span>\u00a0.\u00a0Dose equivalente \u00e9 dada a s\u00edmbolo H\u00a0<\/span><sub><span>t<\/span><\/sub><span>\u00a0.\u00a0A unidade SI de\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>t<\/span><\/sub><\/strong><span>\u00a0\u00e9 o\u00a0<\/span><strong><span>Sievert<\/span><\/strong><span>\u00a0(Sv) ou mas REM (\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-roentgen-equivalent-man-rem-unit-definition\/\"><span>homem equivalente roentgen<\/span><\/a><span>\u00a0) ainda \u00e9 vulgarmente utilizado (\u00a0<\/span><strong><span>1 Sv = 100 REM<\/span><\/strong><span>\u00a0).<\/span><\/p>\n<h3><span>Exemplos de doses em Sieverts<\/span><\/h3>\n<p><span>Devemos notar que a\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/\"><span>radia\u00e7\u00e3o<\/span><\/a><span>\u00a0est\u00e1 \u00e0 nossa volta.\u00a0Dentro, ao redor e acima do mundo em que vivemos. \u00c9 uma for\u00e7a de energia natural que nos rodeia.\u00a0\u00c9 uma parte do nosso mundo natural que est\u00e1 aqui desde o nascimento do nosso planeta.\u00a0Nos pontos a seguir, tentamos expressar enormes faixas de exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o, que podem ser obtidas de v\u00e1rias fontes.<\/span><\/p>\n<ul>\n<li><strong><span>0,05 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dormindo ao lado de algu\u00e9m<\/span><\/li>\n<li><strong><span>0,09 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Morando a 48 quil\u00f4metros de uma usina nuclear por um ano<\/span><\/li>\n<li><strong><span>0,1 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Comendo uma banana<\/span><\/li>\n<li><strong><span>0,3 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Morando a 80 quil\u00f4metros de uma usina a carv\u00e3o por um ano<\/span><\/li>\n<li><strong><span>10 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia di\u00e1ria recebida do fundo natural<\/span><\/li>\n<li><strong><span>20 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; radiografia de t\u00f3rax<\/span><\/li>\n<li><strong><span>40 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Um voo de avi\u00e3o de 5 horas<\/span><\/li>\n<li><strong><span>600 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; mamografia<\/span><\/li>\n<li><strong><span>1 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Limite de dose para membros individuais do p\u00fablico, dose efetiva total por ano<\/span><\/li>\n<li><strong><span>3 650 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia anual recebida do fundo natural<\/span><\/li>\n<li><strong><span>5 800 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; tomografia computadorizada do t\u00f3rax<\/span><\/li>\n<li><strong><span>10 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia anual recebida do ambiente natural em Ramsar, Ir\u00e3<\/span><\/li>\n<li><strong><span>20 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; tomografia computadorizada de corpo inteiro<\/span><\/li>\n<li><strong><span>175 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose anual de radia\u00e7\u00e3o natural em uma praia de monazita perto de Guarapari, Brasil.<\/span><\/li>\n<li><strong><span>5 000 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose que mata um ser humano com um risco de 50% dentro de 30 dias (LD50 \/ 30), se a dose for recebida por um per\u00edodo\u00a0<\/span><strong><span>muito curto<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<\/ul>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Um dos\u00edmetro termoluminescente, abreviado como TLD, \u00e9 um dos\u00edmetro de radia\u00e7\u00e3o passiva, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante medindo a intensidade da luz vis\u00edvel emitida por um cristal sens\u00edvel no detector quando o cristal \u00e9 aquecido.\u00a0Dosimetria de Radia\u00e7\u00e3o Um\u00a0dos\u00edmetro termoluminescente\u00a0, abreviado como\u00a0TLD\u00a0, \u00e9 um\u00a0dos\u00edmetro de radia\u00e7\u00e3o passiva\u00a0, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante &#8230; <a title=\"O que \u00e9 um dos\u00edmetro termoluminescente &#8211; TLD &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/\" aria-label=\"More on O que \u00e9 um dos\u00edmetro termoluminescente &#8211; TLD &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 um dos\u00edmetro termoluminescente - TLD - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"Um dos\u00edmetro termoluminescente, abreviado como TLD, \u00e9 um dos\u00edmetro de radia\u00e7\u00e3o passiva, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante medindo a intensidade da luz vis\u00edvel emitida por um cristal sens\u00edvel no detector quando o cristal \u00e9 aquecido. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 um dos\u00edmetro termoluminescente - TLD - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"Um dos\u00edmetro termoluminescente, abreviado como TLD, \u00e9 um dos\u00edmetro de radia\u00e7\u00e3o passiva, que mede a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o ionizante medindo a intensidade da luz vis\u00edvel emitida por um cristal sens\u00edvel no detector quando o cristal \u00e9 aquecido. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-20T11:32:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-20T11:33:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Glow-Curve-TLD-Reader.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"10 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Glow-Curve-TLD-Reader.png\",\"width\":440,\"height\":302,\"caption\":\"Gl\\u00fchkurvenquelle: Dosimetrie. Studienf\\u00fchrer f\\u00fcr radiologische Kontrolltechniker. DOE-HDBK-1122-99. Energiebeh\\u00f6rde\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/\",\"name\":\"O que \\u00e9 um dos\\u00edmetro termoluminescente - TLD - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/#primaryimage\"},\"datePublished\":\"2020-07-20T11:32:31+00:00\",\"dateModified\":\"2020-07-20T11:33:39+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Um dos\\u00edmetro termoluminescente, abreviado como TLD, \\u00e9 um dos\\u00edmetro de radia\\u00e7\\u00e3o passiva, que mede a exposi\\u00e7\\u00e3o \\u00e0 radia\\u00e7\\u00e3o ionizante medindo a intensidade da luz vis\\u00edvel emitida por um cristal sens\\u00edvel no detector quando o cristal \\u00e9 aquecido. Dosimetria de Radia\\u00e7\\u00e3o\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-um-dosimetro-termoluminescente-tld-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/21572"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=21572"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/21572\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=21572"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=21572"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=21572"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}