{"id":18099,"date":"2020-06-26T22:47:26","date_gmt":"2020-06-26T22:47:26","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/"},"modified":"2020-07-24T06:18:42","modified_gmt":"2020-07-24T06:18:42","slug":"o-que-e-coeficiente-de-conversao-interna-icc-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/","title":{"rendered":"O que \u00e9 coeficiente de convers\u00e3o interna &#8211; ICC &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">O coeficiente de convers\u00e3o interna (ICC), \u03b1, caracteriza a competi\u00e7\u00e3o entre convers\u00e3o interna e emiss\u00e3o de raios gama.\u00a0Em alguns casos, a convers\u00e3o interna \u00e9 preferida ao decaimento gama.\u00a0Dosimetria de Radia\u00e7\u00e3o<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<figure id=\"attachment_25106\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-25106\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger.png\"><img loading=\"lazy\" class=\"size-medium wp-image-25106 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" alt=\"Convers\u00e3o interna - ICE plus Auger\" width=\"280\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" \/><\/a><figcaption id=\"caption-attachment-25106\" class=\"wp-caption-text\">Convers\u00e3o interna seguida por emiss\u00e3o de el\u00e9trons Auger.<\/figcaption><\/figure>\n<p><strong>A convers\u00e3o interna<\/strong>\u00a0\u00e9 um processo eletromagn\u00e9tico, pelo qual um estado nuclear excitado decai pela\u00a0<strong>emiss\u00e3o direta<\/strong>\u00a0de um de seus\u00a0<strong>el\u00e9trons at\u00f4micos<\/strong>\u00a0.\u00a0<strong>A convers\u00e3o interna<\/strong>\u00a0compete com\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/gamma-decay-gamma-radioactivity\/\">a emiss\u00e3o gama<\/a>\u00a0, mas, neste caso, os campos multipolares eletromagn\u00e9ticos do\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/atomic-nucleus\/\">n\u00facleo<\/a>\u00a0n\u00e3o resultam na emiss\u00e3o de um raio gama; em vez disso, os campos interagem diretamente com os el\u00e9trons at\u00f4micos.<\/p>\n<h2>Coeficiente de convers\u00e3o interna<\/h2>\n<p>O\u00a0<strong>coeficiente de convers\u00e3o interna<\/strong>\u00a0(ICC),\u00a0<strong>\u03b1<\/strong>\u00a0, caracteriza a competi\u00e7\u00e3o entre convers\u00e3o interna e emiss\u00e3o de raios gama.\u00a0Em alguns casos, a convers\u00e3o interna \u00e9 preferida ao decaimento gama.\u00a0Em outros, pode ser completamente insignificante.\u00a0O\u00a0<strong>coeficiente de convers\u00e3o interno<\/strong>\u00a0\u00e9 definido como a raz\u00e3o entre o n\u00famero de decaimentos de convers\u00e3o internos e o n\u00famero de decaimentos gama.\u00a0Essa CCI \u00e9 definida para cada inv\u00f3lucro de el\u00e9trons (ou seja, os inv\u00f3lucros K, L e M, etc), de modo que a raz\u00e3o total, \u03b1\u00a0<sub>total<\/sub>\u00a0, seja a soma dos ICCs para cada inv\u00f3lucro como:<\/p>\n<p>ct\u00a0<sub>totais<\/sub>\u00a0= ct\u00a0<sub>K<\/sub>\u00a0+ \u03b1\u00a0<sub>G<\/sub>\u00a0+ \u03b1\u00a0<sub>H<\/sub>\u00a0= n\u00famero de IC \/ n\u00famero de decaimentos gamma<\/p>\n<p>Por exemplo, no decaimento do estado excitado a 35 keV de\u00a0<sup>125<\/sup>\u00a0Te (produzido pelo decaimento de 125I), 7% dos decaimentos emitem raios gama, enquanto 93% emitem el\u00e9trons de convers\u00e3o.\u00a0Portanto, um coeficiente de convers\u00e3o interno desse estado excitado (\u00a0<sup>125<\/sup>\u00a0Te) \u00e9 ICC = 93\/7 = 13,3.<\/p>\n<p>Usando a calculadora do Coeficiente de Convers\u00e3o Interna Band-Raman, os ICCs podem ser calculados usando princ\u00edpios da f\u00edsica at\u00f4mica, uma vez que depende principalmente da densidade dos el\u00e9trons at\u00f4micos no centro do n\u00facleo.\u00a0Para aumentar o n\u00famero at\u00f4mico (Z) e diminuir a energia dos raios gama, observa-se um aumento nos coeficientes de convers\u00e3o internos.<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>O coeficiente de convers\u00e3o interna (ICC), \u03b1, caracteriza a competi\u00e7\u00e3o entre convers\u00e3o interna e emiss\u00e3o de raios gama.\u00a0Em alguns casos, a convers\u00e3o interna \u00e9 preferida ao decaimento gama.\u00a0Dosimetria de Radia\u00e7\u00e3o Convers\u00e3o interna seguida por emiss\u00e3o de el\u00e9trons Auger. A convers\u00e3o interna\u00a0\u00e9 um processo eletromagn\u00e9tico, pelo qual um estado nuclear excitado decai pela\u00a0emiss\u00e3o direta\u00a0de um de &#8230; <a title=\"O que \u00e9 coeficiente de convers\u00e3o interna &#8211; ICC &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/\" aria-label=\"More on O que \u00e9 coeficiente de convers\u00e3o interna &#8211; ICC &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 coeficiente de convers\u00e3o interna - ICC - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"O coeficiente de convers\u00e3o interna (ICC), \u03b1, caracteriza a competi\u00e7\u00e3o entre convers\u00e3o interna e emiss\u00e3o de raios gama. Em alguns casos, a convers\u00e3o interna \u00e9 preferida ao decaimento gama. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 coeficiente de convers\u00e3o interna - ICC - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"O coeficiente de convers\u00e3o interna (ICC), \u03b1, caracteriza a competi\u00e7\u00e3o entre convers\u00e3o interna e emiss\u00e3o de raios gama. Em alguns casos, a convers\u00e3o interna \u00e9 preferida ao decaimento gama. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-26T22:47:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-24T06:18:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger.png\",\"width\":746,\"height\":799,\"caption\":\"Conversion interne suivie d'une \\u00e9mission d'\\u00e9lectrons Auger.\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/\",\"name\":\"O que \\u00e9 coeficiente de convers\\u00e3o interna - ICC - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/#primaryimage\"},\"datePublished\":\"2020-06-26T22:47:26+00:00\",\"dateModified\":\"2020-07-24T06:18:42+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"O coeficiente de convers\\u00e3o interna (ICC), \\u03b1, caracteriza a competi\\u00e7\\u00e3o entre convers\\u00e3o interna e emiss\\u00e3o de raios gama. Em alguns casos, a convers\\u00e3o interna \\u00e9 preferida ao decaimento gama. Dosimetria de Radia\\u00e7\\u00e3o\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-coeficiente-de-conversao-interna-icc-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/18099"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=18099"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/18099\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=18099"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=18099"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=18099"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}