{"id":17691,"date":"2020-06-18T17:57:14","date_gmt":"2020-06-18T17:57:14","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/"},"modified":"2020-07-22T06:19:30","modified_gmt":"2020-07-22T06:19:30","slug":"o-que-e-camara-proporcional-misturas-de-gas-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/","title":{"rendered":"O que \u00e9 C\u00e2mara Proporcional &#8211; Misturas de G\u00e1s &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Arg\u00f4nio e h\u00e9lio s\u00e3o os gases de enchimento mais usados \u200b\u200be permitem a detec\u00e7\u00e3o de radia\u00e7\u00e3o alfa, beta e gama.\u00a0Para a detec\u00e7\u00e3o de n\u00eautrons, He-3 e BF3 (trifluoreto de boro) s\u00e3o os gases mais empregados.\u00a0C\u00e2mara Proporcional &#8211; Misturas de G\u00e1s<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p>Um\u00a0\u00a0<strong>contador proporcional<\/strong>\u00a0, tamb\u00e9m conhecido como\u00a0<strong>detector proporcional<\/strong>\u00a0, \u00e9 um dispositivo el\u00e9trico que detecta v\u00e1rios tipos de radia\u00e7\u00e3o ionizante.\u00a0A tens\u00e3o do detector \u00e9 ajustada para que as condi\u00e7\u00f5es correspondam \u00e0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/operating-regions-of-ionizing-detectors-detector-voltage\/proportional-region-ionization-detector\/\">regi\u00e3o proporcional<\/a>\u00a0.\u00a0Nesta regi\u00e3o, a voltagem \u00e9 alta o suficiente para fornecer aos el\u00e9trons prim\u00e1rios acelera\u00e7\u00e3o e energia suficientes para que eles possam ionizar \u00e1tomos adicionais do meio.\u00a0Esses \u00edons secund\u00e1rios (\u00a0<strong>amplifica\u00e7\u00e3o de g\u00e1s<\/strong>\u00a0) formados tamb\u00e9m s\u00e3o acelerados, causando um efeito conhecido como\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/operating-regions-of-ionizing-detectors-detector-voltage\/townsend-avalanche\/\"><strong>avalanches de Townsend<\/strong><\/a>\u00a0, que cria um \u00fanico pulso el\u00e9trico grande.\u00a0Os contadores proporcionais gasosos geralmente operam em campos el\u00e9tricos altos da ordem de 10 kV \/ cm e atingem<strong>fatores de amplifica\u00e7\u00e3o de cerca de 10\u00a0<sup>5<\/sup><\/strong>\u00a0.\u00a0Como o fator de amplifica\u00e7\u00e3o depende fortemente da tens\u00e3o aplicada, a carga coletada (sinal de sa\u00edda) tamb\u00e9m depende da tens\u00e3o aplicada e os contadores proporcionais exigem tens\u00e3o constante.<\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Gaseous-Ionization-Detectors-Regions-min.png\"><img loading=\"lazy\" class=\"size-medium wp-image-26092 alignright lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Gaseous-Ionization-Detectors-Regions-min-300x177.png\" alt=\"Detectores de ioniza\u00e7\u00e3o gasosa - Regi\u00f5es\" width=\"300\" height=\"177\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Gaseous-Ionization-Detectors-Regions-min-300x177.png\" \/><\/a><\/p>\n<p>Arg\u00f4nio e h\u00e9lio s\u00e3o os gases de enchimento mais usados \u200b\u200be permitem a detec\u00e7\u00e3o de radia\u00e7\u00e3o alfa, beta e gama.\u00a0Para a detec\u00e7\u00e3o de n\u00eautrons, He-3 e BF\u00a0<sub>3<\/sub>\u00a0(trifluoreto de boro) s\u00e3o os gases mais empregados.\u00a0Para fins especiais, foram utilizadas outras misturas de gases, como uma mistura de gases equivalente ao tecido, que consiste em 64,4% de metano, 32,4% de di\u00f3xido de carbono e 3,2% de nitrog\u00eanio.<\/p>\n<p>&nbsp;<\/p>\n<h2>T\u00eampera &#8211; Contadores Proporcionais<\/h2>\n<p>Num contador proporcional, o g\u00e1s de enchimento da c\u00e2mara \u00e9 um g\u00e1s inerte que \u00e9 ionizado por radia\u00e7\u00e3o incidente e um g\u00e1s de t\u00eampera para garantir que cada descarga de pulso termine;\u00a0uma mistura comum \u00e9 90% arg\u00f4nio, 10% metano, conhecido como P-10.<\/p>\n<p>Para cada el\u00e9tron coletado na c\u00e2mara, resta um \u00edon de g\u00e1s carregado positivamente.\u00a0Esses \u00edons gasosos s\u00e3o pesados \u200b\u200bem compara\u00e7\u00e3o com um el\u00e9tron e se movem muito mais lentamente.\u00a0Os el\u00e9trons livres s\u00e3o muito mais leves que os \u00edons positivos; portanto, eles s\u00e3o atra\u00eddos para o eletrodo central positivo muito mais rapidamente do que os \u00edons positivos s\u00e3o atra\u00eddos para a parede da c\u00e2mara.\u00a0A nuvem resultante de \u00edons positivos pr\u00f3ximos ao eletrodo leva a distor\u00e7\u00f5es na multiplica\u00e7\u00e3o de gases.\u00a0Eventualmente, os \u00edons positivos se afastam do fio central com carga positiva para a parede com carga negativa e s\u00e3o neutralizados atrav\u00e9s da obten\u00e7\u00e3o de um el\u00e9tron.\u00a0No processo, parte da energia \u00e9 liberada, o que causa ioniza\u00e7\u00e3o adicional dos \u00e1tomos de g\u00e1s.\u00a0Os el\u00e9trons produzidos por essa ioniza\u00e7\u00e3o se movem em dire\u00e7\u00e3o ao fio central e s\u00e3o multiplicados no caminho.\u00a0Esse pulso de carga n\u00e3o est\u00e1 relacionado \u00e0 radia\u00e7\u00e3o a ser detectada e pode acionar uma s\u00e9rie de pulsos.\u00a0Na pr\u00e1tica, o t\u00e9rmino da avalanche \u00e9 aprimorado pelo uso de &#8220;<strong>extin\u00e7\u00e3o<\/strong>\u00a0\u201d.<\/p>\n<p>As mol\u00e9culas de g\u00e1s de t\u00eampera t\u00eam uma afinidade mais fraca pelos el\u00e9trons do que o g\u00e1s da c\u00e2mara;\u00a0portanto, os \u00e1tomos ionizados do g\u00e1s da c\u00e2mara retiram prontamente el\u00e9trons das mol\u00e9culas de g\u00e1s de extin\u00e7\u00e3o.\u00a0Assim, as mol\u00e9culas ionizadas do g\u00e1s de t\u00eampera atingem a parede da c\u00e2mara em vez do g\u00e1s da c\u00e2mara.\u00a0As mol\u00e9culas ionizadas do g\u00e1s de t\u00eampera s\u00e3o neutralizadas pelo ganho de um el\u00e9tron, e a energia liberada n\u00e3o causa mais ioniza\u00e7\u00e3o, mas causa a dissocia\u00e7\u00e3o da mol\u00e9cula.<\/p>\n<p><strong>Refer\u00eancia especial:\u00a0<\/strong><strong>Departamento de Energia, Instrumanta\u00e7\u00e3o e Controle dos EUA.\u00a0DOE Fundamentals Handbook, Volume 2, de 2 de junho de 1992.<\/strong><\/p>\n<h3>Detec\u00e7\u00e3o de n\u00eautrons usando o contador proporcional<\/h3>\n<p>Como os n\u00eautrons s\u00e3o\u00a0<strong>part\u00edculas eletricamente neutras,<\/strong>\u00a0elas est\u00e3o sujeitas principalmente a fortes for\u00e7as nucleares, mas n\u00e3o a for\u00e7as el\u00e9tricas.\u00a0Portanto, os n\u00eautrons\u00a0<strong>n\u00e3o<\/strong>\u00a0s\u00e3o\u00a0<strong>diretamente ionizantes<\/strong>\u00a0e geralmente precisam ser\u00a0<strong>convertidos<\/strong>\u00a0em part\u00edculas carregadas antes que possam ser detectados.\u00a0Geralmente, todo tipo de detector de n\u00eautrons deve estar equipado com conversor (para converter a radia\u00e7\u00e3o de n\u00eautrons em radia\u00e7\u00e3o detect\u00e1vel comum) e um dos detectores de radia\u00e7\u00e3o convencionais (detector de cintila\u00e7\u00e3o, detector de gases, detector de semicondutores, etc.).<\/p>\n<p>Contadores proporcionais s\u00e3o frequentemente usados \u200b\u200bcomo dispositivo de detec\u00e7\u00e3o de part\u00edculas carregadas.\u00a0Nas usinas nucleares, os\u00a0contadores proporcionais a\u00a0g\u00e1s (BF\u00a0<sub>3<\/sub>\u00a0) s\u00e3o normalmente usados \u200b\u200bcomo detectores de faixa de fonte.\u00a0Esses detectores usam o trifluoreto de boro gasoso (BF\u00a0<sub>3<\/sub>\u00a0) em vez de ar na c\u00e2mara.\u00a0Os n\u00eautrons recebidos produzem part\u00edculas alfa quando reagem com os \u00e1tomos de boro no g\u00e1s detector.\u00a0A maioria das rea\u00e7\u00f5es (n, alfa) dos n\u00eautrons t\u00e9rmicos s\u00e3o rea\u00e7\u00f5es\u00a0<strong>10B (n, alfa) 7Li<\/strong>\u00a0acompanhadas por\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/photon\/gamma-ray\/\">emiss\u00e3o gama de<\/a>\u00a00,48 MeV\u00a0.<\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-12477 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\" alt=\"(n, alfa) rea\u00e7\u00f5es de 10B\" width=\"665\" height=\"99\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\" \/><\/a><\/p>\n<p>Al\u00e9m disso, o is\u00f3topo\u00a0<a href=\"https:\/\/www.nuclear-power.com\/glossary\/boron-10\/\">boro-10<\/a>\u00a0possui uma alta se\u00e7\u00e3o transversal da rea\u00e7\u00e3o (n, alfa) ao longo de todo\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/neutron\/neutron-energy\/\">o espectro de energia de n\u00eautrons<\/a> . A part\u00edcula alfa causa ioniza\u00e7\u00e3o dentro da c\u00e2mara e el\u00e9trons ejetados causam ioniza\u00e7\u00f5es secund\u00e1rias adicionais.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Arg\u00f4nio e h\u00e9lio s\u00e3o os gases de enchimento mais usados \u200b\u200be permitem a detec\u00e7\u00e3o de radia\u00e7\u00e3o alfa, beta e gama.\u00a0Para a detec\u00e7\u00e3o de n\u00eautrons, He-3 e BF3 (trifluoreto de boro) s\u00e3o os gases mais empregados.\u00a0C\u00e2mara Proporcional &#8211; Misturas de G\u00e1s Um\u00a0\u00a0contador proporcional\u00a0, tamb\u00e9m conhecido como\u00a0detector proporcional\u00a0, \u00e9 um dispositivo el\u00e9trico que detecta v\u00e1rios tipos de &#8230; <a title=\"O que \u00e9 C\u00e2mara Proporcional &#8211; Misturas de G\u00e1s &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/\" aria-label=\"More on O que \u00e9 C\u00e2mara Proporcional &#8211; Misturas de G\u00e1s &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 C\u00e2mara Proporcional - Misturas de G\u00e1s - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"Arg\u00f4nio e h\u00e9lio s\u00e3o os gases de enchimento mais usados e permitem a detec\u00e7\u00e3o de radia\u00e7\u00e3o alfa, beta e gama. Para a detec\u00e7\u00e3o de n\u00eautrons, He-3 e BF3 (trifluoreto de boro) s\u00e3o os gases mais empregados. C\u00e2mara Proporcional - Misturas de G\u00e1s\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 C\u00e2mara Proporcional - Misturas de G\u00e1s - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"Arg\u00f4nio e h\u00e9lio s\u00e3o os gases de enchimento mais usados e permitem a detec\u00e7\u00e3o de radia\u00e7\u00e3o alfa, beta e gama. Para a detec\u00e7\u00e3o de n\u00eautrons, He-3 e BF3 (trifluoreto de boro) s\u00e3o os gases mais empregados. C\u00e2mara Proporcional - Misturas de G\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-18T17:57:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-22T06:19:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Gaseous-Ionization-Detectors-Regions-min-300x177.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"http:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Gaseous-Ionization-Detectors-Regions-min-300x177.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/\",\"name\":\"O que \\u00e9 C\\u00e2mara Proporcional - Misturas de G\\u00e1s - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/#primaryimage\"},\"datePublished\":\"2020-06-18T17:57:14+00:00\",\"dateModified\":\"2020-07-22T06:19:30+00:00\",\"author\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Arg\\u00f4nio e h\\u00e9lio s\\u00e3o os gases de enchimento mais usados e permitem a detec\\u00e7\\u00e3o de radia\\u00e7\\u00e3o alfa, beta e gama. Para a detec\\u00e7\\u00e3o de n\\u00eautrons, He-3 e BF3 (trifluoreto de boro) s\\u00e3o os gases mais empregados. C\\u00e2mara Proporcional - Misturas de G\\u00e1s\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-proporcional-misturas-de-gas-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17691"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=17691"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17691\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=17691"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=17691"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=17691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}