{"id":17557,"date":"2020-06-15T03:45:59","date_gmt":"2020-06-15T03:45:59","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/"},"modified":"2020-07-21T11:30:10","modified_gmt":"2020-07-21T11:30:10","slug":"o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/","title":{"rendered":"O que \u00e9 c\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">C\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores. As c\u00e2maras de ioniza\u00e7\u00e3o s\u00e3o preferidas para altas taxas de dose de radia\u00e7\u00e3o porque n\u00e3o possuem &#8220;tempo morto&#8221;. Os detectores de semicondutores s\u00e3o amplamente utilizados na prote\u00e7\u00e3o contra radia\u00e7\u00e3o. Dosimetria de Radia\u00e7\u00e3o<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-50 lgc-tablet-grid-50 lgc-mobile-grid-100 lgc-equal-heights  lgc-first\">\n<div class=\"inside-grid-column\">\n<h2><span>C\u00e2maras de ioniza\u00e7\u00e3o<\/span><\/h2>\n<p><span>A\u00a0<strong><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/ionization-chamber-ion-chamber\/\">c\u00e2mara de ioniza\u00e7\u00e3o<\/a><\/strong>\u00a0, tamb\u00e9m conhecida como\u00a0\u00a0<strong>c\u00e2mara de \u00edons<\/strong>\u00a0, \u00e9 um dispositivo el\u00e9trico que detecta v\u00e1rios tipos de\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/ionizing-radiation\/\">radia\u00e7\u00e3o ionizante<\/a>\u00a0.\u00a0A tens\u00e3o do detector \u00e9 ajustada para que as condi\u00e7\u00f5es correspondam \u00e0\u00a0\u00a0<strong>regi\u00e3o de ioniza\u00e7\u00e3o<\/strong>\u00a0.\u00a0A tens\u00e3o n\u00e3o \u00e9 alta o suficiente para produzir amplifica\u00e7\u00e3o de g\u00e1s (ioniza\u00e7\u00e3o secund\u00e1ria).<\/span><strong>\u00a0<\/strong><\/p>\n<h3><span>Vantagens das c\u00e2maras de ioniza\u00e7\u00e3o<\/span><\/h3>\n<ul>\n<li><strong><span>Modo atual.\u00a0As c\u00e2maras de ioniza\u00e7\u00e3o<\/span><\/strong><span>\u00a0\u00a0s\u00e3o preferidas\u00a0\u00a0<\/span><strong><span>para altas taxas de dose de radia\u00e7\u00e3o,<\/span><\/strong><span>\u00a0\u00a0porque n\u00e3o t\u00eam \u201ctempo morto\u201d, um fen\u00f4meno que afeta a precis\u00e3o do tubo Geiger-Mueller em altas taxas de dose.\u00a0Isso se deve ao fato de n\u00e3o haver amplifica\u00e7\u00e3o de sinal inerente no meio operacional e, portanto, esses tipos de contadores n\u00e3o requerem muito tempo para se recuperar de grandes correntes.\u00a0Al\u00e9m disso, como n\u00e3o h\u00e1 amplifica\u00e7\u00e3o, eles oferecem excelente resolu\u00e7\u00e3o de energia, limitada principalmente pelo ru\u00eddo eletr\u00f4nico.\u00a0C\u00e2maras de ioniza\u00e7\u00e3o podem ser operadas no\u00a0\u00a0<\/span><strong><span>modo atual ou de pulso<\/span><\/strong><span>.\u00a0Por outro lado, contadores proporcionais ou contadores Geiger s\u00e3o quase sempre usados \u200b\u200bno modo de pulso.\u00a0Detectores de radia\u00e7\u00e3o ionizante podem ser usados \u200b\u200btanto para medi\u00e7\u00f5es de atividade quanto para medi\u00e7\u00f5es de dose.\u00a0Com o conhecimento sobre a energia necess\u00e1ria para formar um par de \u00edons &#8211; a dose pode ser obtida.\u00a0O\u00a0\u00a0<\/span><strong><span>design da placa plana \u00e9 preferido<\/span><\/strong><span>\u00a0\u00a0porque possui um volume ativo bem definido e garante que os \u00edons n\u00e3o se acumulem nos isoladores e causem uma distor\u00e7\u00e3o do campo el\u00e9trico.<\/span><\/li>\n<li><strong><span>Simplicidade<\/span><\/strong><span>\u00a0.\u00a0A corrente de sa\u00edda \u00e9 independente da tens\u00e3o de opera\u00e7\u00e3o do detector.\u00a0Observe a regi\u00e3o plana da curva na regi\u00e3o da c\u00e2mara de \u00edons.\u00a0Como resultado, fontes de alimenta\u00e7\u00e3o menos reguladas e, portanto, mais baratas e mais port\u00e1teis podem ser usadas com instrumentos de c\u00e2mara de \u00edons e ainda oferecem uma resposta razoavelmente precisa.<\/span><\/li>\n<li><strong><span>Detec\u00e7\u00e3o de n\u00eautrons<\/span><\/strong><span>\u00a0.\u00a0Nos reatores nucleares, as c\u00e2maras de ioniza\u00e7\u00e3o no modo atual s\u00e3o frequentemente usadas para detectar n\u00eautrons e pertencem ao Sistema de Instrumenta\u00e7\u00e3o de N\u00eautrons (NIS).\u00a0Por exemplo, se a superf\u00edcie interna da c\u00e2mara de ioniza\u00e7\u00e3o for revestida com uma fina camada de boro, a rea\u00e7\u00e3o (n, alfa) poder\u00e1 ocorrer.\u00a0A maioria das rea\u00e7\u00f5es (n, alfa) dos n\u00eautrons t\u00e9rmicos s\u00e3o rea\u00e7\u00f5es\u00a0\u00a0<\/span><strong><span>10B (n, alfa) 7Li\u00a0<\/span><\/strong><span>\u00a0acompanhadas por\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/photon\/gamma-ray\/\"><span>emiss\u00e3o gama de<\/span><\/a><span>\u00a00,48 MeV\u00a0\u00a0.\u00a0Al\u00e9m disso, o is\u00f3topo boro-10 possui uma alta se\u00e7\u00e3o transversal da rea\u00e7\u00e3o (n, alfa) ao longo de todo\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/neutron\/neutron-energy\/\"><span>o espectro de energia de n\u00eautrons<\/span><\/a><span>\u00a0.\u00a0A part\u00edcula alfa causa ioniza\u00e7\u00e3o dentro da c\u00e2mara e el\u00e9trons ejetados causam ioniza\u00e7\u00f5es secund\u00e1rias adicionais.\u00a0Outro m\u00e9todo para detectar n\u00eautrons usando uma c\u00e2mara de ioniza\u00e7\u00e3o \u00e9 usar o g\u00e1s\u00a0<\/span><strong><span>trifluoreto de boro<\/span><\/strong><span>\u00a0\u00a0(BF\u00a0<\/span><sub><span>3<\/span><\/sub><span>\u00a0) em vez de ar na c\u00e2mara.\u00a0Os n\u00eautrons recebidos produzem part\u00edculas alfa quando reagem com os \u00e1tomos de boro no g\u00e1s detector.\u00a0Qualquer um dos m\u00e9todos pode ser usado para detectar n\u00eautrons no reator nuclear.<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-12477 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\" sizes=\"(max-width: 665px) 100vw, 665px\" srcset=\"http:\/\/radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png 665w, https:\/\/www.nuclear-power.com\/wp-content\/uploads\/2015\/08\/Boron-neutron-reaction-300x45.png 300w\" alt=\"(n, alfa) rea\u00e7\u00f5es de 10B\" width=\"665\" height=\"99\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\" data-srcset=\"\" \/><\/a><\/li>\n<\/ul>\n<h3><span>Desvantagens das c\u00e2maras de ioniza\u00e7\u00e3o<\/span><\/h3>\n<ul>\n<li><strong><span>Sem amplifica\u00e7\u00e3o de carga<\/span><\/strong><span>\u00a0.\u00a0Os detectores na regi\u00e3o de ioniza\u00e7\u00e3o operam com uma for\u00e7a de campo el\u00e9trico baixa, selecionada de forma que n\u00e3o ocorra multiplica\u00e7\u00e3o de g\u00e1s.\u00a0A carga coletada (sinal de sa\u00edda) \u00e9 independente da tens\u00e3o aplicada e as part\u00edculas ionizantes m\u00ednimas tendem a ser bem pequenas e geralmente requerem amplificadores especiais de baixo ru\u00eddo para obter desempenho operacional eficiente.\u00a0No ar, a energia m\u00e9dia necess\u00e1ria para produzir um \u00edon \u00e9 de cerca de 34 eV; portanto, uma radia\u00e7\u00e3o de 1 MeV completamente absorvida no detector produz cerca de\u00a0\u00a0<\/span><strong><span>3 x 10\u00a0<\/span><sup><span>4<\/span><\/sup><span>\u00a0\u00a0pares de \u00edons<\/span><\/strong><span>\u00a0.\u00a0No entanto, \u00e9 um sinal pequeno, este sinal pode ser consideravelmente amplificado usando a eletr\u00f4nica padr\u00e3o.\u00a0Uma corrente de 1 micro-amp\u00e8re consiste em cerca de 10\u00a0<\/span><sup><span>12<\/span><\/sup><span>\u00a0\u00a0el\u00e9trons por segundo.<\/span><\/li>\n<li><strong><span>Baixa densidade<\/span><\/strong><span>\u00a0.\u00a0Os raios gama depositam uma quantidade significativamente menor de energia no detector do que outras part\u00edculas.\u00a0A efici\u00eancia da c\u00e2mara pode ser aumentada ainda mais pelo uso de um g\u00e1s de alta press\u00e3o.<\/span><\/li>\n<li><span>Para que as\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/beta-particle\/\">part\u00edculas\u00a0<\/a><\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/alpha-particle\/\"><span>alfa<\/span><\/a><span>\u00a0\u00a0e\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/beta-particle\/\"><span>beta<\/span><\/a><span>\u00a0\u00a0sejam detectadas pelas c\u00e2maras de ioniza\u00e7\u00e3o, elas devem ter uma\u00a0\u00a0<\/span><strong><span>janela fina<\/span><\/strong><span>\u00a0.\u00a0Essa &#8220;janela final&#8221; deve ser fina o suficiente para que as part\u00edculas alfa e beta penetrem.\u00a0No entanto, uma janela de quase qualquer espessura impedir\u00e1 que uma part\u00edcula alfa entre na c\u00e2mara.\u00a0A janela \u00e9 geralmente feita de mica com uma densidade de cerca de 1,5 &#8211; 2,0 mg \/ cm\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0.<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-50 lgc-tablet-grid-50 lgc-mobile-grid-100 lgc-equal-heights  lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Detectores de semicondutores<\/span><\/h2>\n<p><span>Um\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/\"><strong><span>detector de semicondutores<\/span><\/strong><\/a><span>\u00a0\u00a0\u00e9 um detector de radia\u00e7\u00e3o que se baseia em um\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/\"><strong><span>semicondutor<\/span><\/strong><\/a><span>\u00a0, como\u00a0\u00a0<\/span><strong><span>sil\u00edcio<\/span><\/strong><span>\u00a0\u00a0ou\u00a0\u00a0<\/span><strong><span>germ\u00e2nio,<\/span><\/strong><span>\u00a0\u00a0para medir o efeito de part\u00edculas ou f\u00f3tons carregados incidentes.\u00a0<\/span><strong><span>Os detectores de semicondutores<\/span><\/strong><span>\u00a0\u00a0s\u00e3o amplamente utilizados em\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/\"><span>prote\u00e7\u00e3o contra radia\u00e7\u00e3o<\/span><\/a><span>\u00a0, ensaio de materiais radioativos e pesquisa em f\u00edsica porque possuem algumas caracter\u00edsticas \u00fanicas, podem ser fabricados de maneira barata e com boa efici\u00eancia e podem medir a intensidade e a energia da radia\u00e7\u00e3o incidente.\u00a0Esses detectores s\u00e3o empregados para medir a energia da radia\u00e7\u00e3o e para identifica\u00e7\u00e3o de part\u00edculas.\u00a0Dos materiais semicondutores dispon\u00edveis, o\u00a0\u00a0<\/span><strong><span>sil\u00edcio<\/span><\/strong><span>\u00a0\u00a0\u00e9 usado principalmente para\u00a0<\/span><strong><span>detectores de part\u00edculas carregadas<\/span><\/strong><span>\u00a0\u00a0(especialmente para rastrear part\u00edculas carregadas) e detectores de raios-X moles, enquanto o\u00a0\u00a0<\/span><strong><span>germ\u00e2nio<\/span><\/strong><span>\u00a0\u00a0\u00e9 amplamente utilizado para\u00a0\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\"><strong><span>espectroscopia de raios gama<\/span><\/strong><\/a><span>\u00a0.<\/span><\/p>\n<h3><span>Vantagens dos detectores HPGe<\/span><\/h3>\n<ul>\n<li><strong><span>Maior n\u00famero at\u00f4mico.\u00a0<\/span><\/strong><span>O germ\u00e2nio \u00e9 preferido devido ao seu\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atomic-nuclear-structure\/atomic-number-proton-number\/\"><span>n\u00famero at\u00f4mico<\/span><\/a><span>\u00a0ser muito maior que o sil\u00edcio e aumentar a probabilidade de intera\u00e7\u00e3o com raios gama.<\/span><\/li>\n<li><span>O germ\u00e2nio possui uma energia m\u00e9dia mais baixa necess\u00e1ria para criar um par de el\u00e9trons-orif\u00edcios, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.<\/span><\/li>\n<li><strong><span>Muito boa resolu\u00e7\u00e3o de energia<\/span><\/strong><span>\u00a0.\u00a0O FWHM para detectores de germ\u00e2nio \u00e9 uma fun\u00e7\u00e3o da energia.\u00a0Para um f\u00f3ton de 1,3 MeV, o FWHM \u00e9 de 2,1 keV, o que \u00e9 muito baixo.<\/span><\/li>\n<li><strong><span>Grandes cristais<\/span><\/strong><span>\u00a0.\u00a0Enquanto os detectores \u00e0 base de sil\u00edcio n\u00e3o podem ser mais grossos que alguns mil\u00edmetros, o germ\u00e2nio pode ter uma espessura sens\u00edvel e esgotada de cent\u00edmetros e, portanto, pode ser usado como um\u00a0<\/span><strong><span>detector de absor\u00e7\u00e3o total<\/span><\/strong><span>\u00a0para raios gama de at\u00e9 poucos MeV.<\/span><\/li>\n<\/ul>\n<h3><span>Desvantagens dos detectores HPGe<\/span><\/h3>\n<ul>\n<li><strong><span>Arrefecimento<\/span><\/strong><span>\u00a0.\u00a0A principal desvantagem dos detectores HPGe \u00e9 que eles devem ser resfriados a temperaturas de nitrog\u00eanio l\u00edquido.\u00a0Como o germ\u00e2nio possui um\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/band-gap-energy-gap\/\"><span>intervalo de banda<\/span><\/a><span>\u00a0relativamente baixo\u00a0, esses detectores devem ser resfriados para reduzir a gera\u00e7\u00e3o t\u00e9rmica de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\"><span>portadores<\/span><\/a><span>\u00a0de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\">carga<\/a>\u00a0para um n\u00edvel aceit\u00e1vel.\u00a0Caso contr\u00e1rio, o ru\u00eddo induzido pela corrente de fuga destr\u00f3i a resolu\u00e7\u00e3o de energia do detector.\u00a0Lembre-se, a diferen\u00e7a de banda (uma dist\u00e2ncia entre a\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/conduction-and-valence-band-in-semiconductors\/\"><span>val\u00eancia e a banda de condu\u00e7\u00e3o<\/span><\/a><span>\u00a0) \u00e9 muito baixa para o germ\u00e2nio (Egap = 0,67 eV).\u00a0O resfriamento at\u00e9 a temperatura do nitrog\u00eanio l\u00edquido (-195,8 \u00b0 C; -320 \u00b0 F) reduz as excita\u00e7\u00f5es t\u00e9rmicas dos el\u00e9trons de val\u00eancia, de modo que apenas uma intera\u00e7\u00e3o de raios gama pode fornecer ao el\u00e9tron a energia necess\u00e1ria para atravessar a folga da banda e alcan\u00e7ar a banda de condu\u00e7\u00e3o.<\/span><\/li>\n<li><strong><span>Pre\u00e7o<\/span><\/strong><span>\u00a0.\u00a0A desvantagem \u00e9 que os detectores de germ\u00e2nio s\u00e3o muito mais caros que as\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/ionization-chamber-ion-chamber\/\"><span>c\u00e2maras de ioniza\u00e7\u00e3o<\/span><\/a><span>\u00a0ou\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/scintillation-counter-scintillation-detector\/\"><span>contadores de cintila\u00e7\u00e3o<\/span><\/a><span>\u00a0.<\/span><\/li>\n<\/ul>\n<h3><span>Vantagens dos detectores de sil\u00edcio<\/span><\/h3>\n<ul>\n<li><span>Comparado aos detectores de ioniza\u00e7\u00e3o gasosa, a densidade de um detector de semicondutor \u00e9 muito alta e part\u00edculas carregadas de alta energia podem liberar sua energia em um semicondutor de dimens\u00f5es relativamente pequenas.<\/span><\/li>\n<li><span>O sil\u00edcio tem uma alta densidade de 2.329 g \/ cm\u00a0<\/span><sup><span>3<\/span><\/sup><span>\u00a0e, portanto, a perda m\u00e9dia de energia por unidade de comprimento permite a constru\u00e7\u00e3o de detectores finos (por exemplo, 300 \u00b5m) que ainda produzem sinais mensur\u00e1veis.\u00a0Por exemplo, no caso de part\u00edculas ionizantes m\u00ednimas (MIP), a perda de energia \u00e9 de 390 eV \/ \u00b5m.\u00a0Os detectores de sil\u00edcio s\u00e3o mecanicamente r\u00edgidos e, portanto, nenhuma estrutura de suporte especial \u00e9 necess\u00e1ria.<\/span><\/li>\n<li><strong><span>Os detectores baseados em sil\u00edcio<\/span><\/strong><span>\u00a0s\u00e3o muito bons para rastrear part\u00edculas carregadas, eles constituem uma parte substancial do sistema de detec\u00e7\u00e3o no LHC no CERN.<\/span><\/li>\n<li><span>Os detectores de sil\u00edcio podem ser usados \u200b\u200bem campos magn\u00e9ticos fortes.<\/span><\/li>\n<\/ul>\n<h3><span>Desvantagens dos detectores de sil\u00edcio<\/span><\/h3>\n<ul>\n<li><strong><span>Pre\u00e7o<\/span><\/strong><span>\u00a0.\u00a0A desvantagem \u00e9 que os detectores de sil\u00edcio s\u00e3o muito mais caros do que as c\u00e2maras de nuvem ou de arame.<\/span><\/li>\n<li><strong><span>Degrada\u00e7\u00e3o<\/span><\/strong><span>\u00a0.\u00a0Eles tamb\u00e9m sofrem degrada\u00e7\u00e3o ao longo do tempo devido \u00e0 radia\u00e7\u00e3o, no entanto, isso pode ser bastante reduzido gra\u00e7as ao efeito L\u00e1zaro.<\/span><\/li>\n<li><strong><span>FWHM alto<\/span><\/strong><span>\u00a0.\u00a0Na espectroscopia gama, o germ\u00e2nio \u00e9 preferido devido ao seu n\u00famero at\u00f4mico ser muito maior que o sil\u00edcio e aumentar a probabilidade de intera\u00e7\u00e3o com raios gama.\u00a0Al\u00e9m disso, o germ\u00e2nio possui menor energia m\u00e9dia necess\u00e1ria para criar um par de el\u00e9trons-orif\u00edcios, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.\u00a0Isso tamb\u00e9m fornece ao \u00faltimo uma melhor resolu\u00e7\u00e3o em energia.<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>C\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores. As c\u00e2maras de ioniza\u00e7\u00e3o s\u00e3o preferidas para altas taxas de dose de radia\u00e7\u00e3o porque n\u00e3o possuem &#8220;tempo morto&#8221;. Os detectores de semicondutores s\u00e3o amplamente utilizados na prote\u00e7\u00e3o contra radia\u00e7\u00e3o. Dosimetria de Radia\u00e7\u00e3o C\u00e2maras de ioniza\u00e7\u00e3o A\u00a0c\u00e2mara de ioniza\u00e7\u00e3o\u00a0, tamb\u00e9m conhecida como\u00a0\u00a0c\u00e2mara de \u00edons\u00a0, \u00e9 um dispositivo el\u00e9trico que &#8230; <a title=\"O que \u00e9 c\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/\" aria-label=\"More on O que \u00e9 c\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 c\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"C\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores. As c\u00e2maras de ioniza\u00e7\u00e3o s\u00e3o preferidas para altas taxas de dose de radia\u00e7\u00e3o porque n\u00e3o possuem &quot;tempo morto&quot;. Os detectores de semicondutores s\u00e3o amplamente utilizados na prote\u00e7\u00e3o contra radia\u00e7\u00e3o. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 c\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"C\u00e2mara de ioniza\u00e7\u00e3o vs detector de semicondutores. As c\u00e2maras de ioniza\u00e7\u00e3o s\u00e3o preferidas para altas taxas de dose de radia\u00e7\u00e3o porque n\u00e3o possuem &quot;tempo morto&quot;. Os detectores de semicondutores s\u00e3o amplamente utilizados na prote\u00e7\u00e3o contra radia\u00e7\u00e3o. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-15T03:45:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-21T11:30:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"7 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/es\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Boron-neutron-reaction.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/\",\"name\":\"O que \\u00e9 c\\u00e2mara de ioniza\\u00e7\\u00e3o vs detector de semicondutores - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/#primaryimage\"},\"datePublished\":\"2020-06-15T03:45:59+00:00\",\"dateModified\":\"2020-07-21T11:30:10+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"C\\u00e2mara de ioniza\\u00e7\\u00e3o vs detector de semicondutores. As c\\u00e2maras de ioniza\\u00e7\\u00e3o s\\u00e3o preferidas para altas taxas de dose de radia\\u00e7\\u00e3o porque n\\u00e3o possuem \\\"tempo morto\\\". Os detectores de semicondutores s\\u00e3o amplamente utilizados na prote\\u00e7\\u00e3o contra radia\\u00e7\\u00e3o. Dosimetria de Radia\\u00e7\\u00e3o\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-camara-de-ionizacao-vs-detector-de-semicondutores-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17557"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=17557"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17557\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=17557"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=17557"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=17557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}