{"id":17449,"date":"2020-06-14T00:35:39","date_gmt":"2020-06-14T00:35:39","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/"},"modified":"2020-07-20T11:37:37","modified_gmt":"2020-07-20T11:37:37","slug":"o-que-e-epd-dosimetro-pessoal-eletronico-definicao","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/","title":{"rendered":"O que \u00e9 EPD &#8211; Dos\u00edmetro pessoal eletr\u00f4nico &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Um dos\u00edmetro pessoal eletr\u00f4nico, EPD, \u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da dose cumulativa e da taxa de dose atual e pode avisar a pessoa que o usa.\u00a0Dosimetria de Radia\u00e7\u00e3o<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p>Um\u00a0<strong>dos\u00edmetro pessoal eletr\u00f4nico<\/strong>\u00a0\u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da\u00a0<strong>dose cumulativa<\/strong>\u00a0e da\u00a0<strong>taxa de dose atual<\/strong>\u00a0e pode avisar a pessoa que o usa quando uma\u00a0<strong>taxa de dose especificada<\/strong>\u00a0ou uma\u00a0<strong>dose cumulativa<\/strong>\u00a0\u00e9 excedida.\u00a0Os EPDs s\u00e3o especialmente \u00fateis em \u00e1reas de altas doses, onde o tempo de perman\u00eancia do usu\u00e1rio \u00e9 limitado devido a restri\u00e7\u00f5es de dose.<\/p>\n<h3><strong>Tipos de EPDs<\/strong><\/h3>\n<figure id=\"attachment_26775\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26775\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/EPD-electronic-personal-dosimeter.png\"><img loading=\"lazy\" class=\"size-full wp-image-26775 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/EPD-electronic-personal-dosimeter.png\" alt=\"EPD - Dos\u00edmetros pessoais eletr\u00f4nicos\" width=\"278\" height=\"299\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/EPD-electronic-personal-dosimeter.png\" \/><\/a><figcaption id=\"caption-attachment-26775\" class=\"wp-caption-text\">EPD &#8211; Dos\u00edmetros pessoais eletr\u00f4nicos com chip Si<\/figcaption><\/figure>\n<p><strong>Os EPDs<\/strong>\u00a0s\u00e3o alimentados por bateria e a maioria usa um pequeno\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/geiger-counter-geiger-mueller-detector\/geiger-muller-tube-geiger-chamber\/\">tubo Geiger-Mueller (GM)<\/a>\u00a0ou um\u00a0<strong>semicondutor<\/strong>\u00a0\u00a0(\u00a0<strong>chip Si<\/strong>\u00a0) no qual a radia\u00e7\u00e3o ionizante libera cargas, resultando em corrente el\u00e9trica mensur\u00e1vel.<\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gaseous-ionization-detector\/geiger-counter-geiger-mueller-detector\/\"><strong>Contador GM<\/strong><\/a>\u00a0.\u00a0Um contador Geiger consiste em um<strong>\u00a0tubo Geiger-M\u00fcller<\/strong>\u00a0(o elemento sensor que detecta a radia\u00e7\u00e3o) e a eletr\u00f4nica de processamento, que exibe o resultado.\u00a0Os contadores GM s\u00e3o usados \u200b\u200bprincipalmente para<strong>\u00a0instrumenta\u00e7\u00e3o port\u00e1til<\/strong>\u00a0devido \u00e0 sua sensibilidade, circuito de contagem simples e capacidade de detectar radia\u00e7\u00e3o de baixo n\u00edvel.\u00a0Devido \u00e0 grande avalanche induzida por qualquer ioniza\u00e7\u00e3o, um contador Geiger leva muito tempo (cerca de 1 ms) para se recuperar entre pulsos sucessivos.\u00a0Portanto, os contadores Geiger n\u00e3o conseguem medir altas taxas de radia\u00e7\u00e3o devido ao &#8220;<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/detectors-of-ionization-radiation\/dead-time-of-detectors\/\"><strong>\u00a0tempo morto<\/strong><\/a>\u00a0&#8221; do tubo.<\/li>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/\"><strong>Detector de semicondutores<\/strong><\/a>\u00a0.\u00a0Os detectores de semicondutores s\u00e3o baseados na ioniza\u00e7\u00e3o de um s\u00f3lido (por exemplo, sil\u00edcio) e incluem diferentes tipos de dispositivos de estado s\u00f3lido com dois terminais chamados diodos.\u00a0Por exemplo, um diodo de sil\u00edcio, que possui uma<strong>\u00a0estrutura de pinos<\/strong>\u00a0na qual a regi\u00e3o intr\u00ednseca (i) \u00e9 sens\u00edvel \u00e0 radia\u00e7\u00e3o ionizante, particularmente raios X e raios gama.\u00a0Sob polariza\u00e7\u00e3o reversa, um campo el\u00e9trico se estende pela regi\u00e3o intr\u00ednseca ou esgotada.\u00a0Nesse caso, a tens\u00e3o negativa \u00e9 aplicada no lado p e positiva no segundo.\u00a0Os furos na regi\u00e3o p s\u00e3o atra\u00eddos da jun\u00e7\u00e3o em dire\u00e7\u00e3o ao contato p e da mesma forma para os el\u00e9trons e o contato n.<\/li>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/scintillation-counter-scintillation-detector\/\"><strong>Detector de cintila\u00e7\u00e3o<\/strong><\/a>\u00a0.\u00a0Alguns EPDs usam um cristal cintilante, como iodeto de s\u00f3dio (NaI) ou iodeto de c\u00e9sio (CsI) com um fotodiodo ou tubo fotomultiplicador para medir os f\u00f3tons liberados pela radia\u00e7\u00e3o.<\/li>\n<\/ul>\n<h3>Caracter\u00edsticas dos EPDs<\/h3>\n<p>O\u00a0<strong>dos\u00edmetro pessoal eletr\u00f4nico, EPD,<\/strong>\u00a0\u00e9 capaz de exibir uma\u00a0<strong>leitura direta<\/strong>\u00a0da dose ou taxa de dose detectada em tempo real.\u00a0Dos\u00edmetros eletr\u00f4nicos podem ser usados \u200b\u200bcomo um dos\u00edmetro suplementar e tamb\u00e9m como um dos\u00edmetro prim\u00e1rio.\u00a0Os dos\u00edmetros passivos e os dos\u00edmetros pessoais eletr\u00f4nicos s\u00e3o frequentemente usados \u200b\u200bjuntos para se complementarem.\u00a0Para estimar doses efetivas, os dos\u00edmetros devem ser usados \u200b\u200bem uma posi\u00e7\u00e3o do corpo representativa de sua exposi\u00e7\u00e3o, geralmente entre a cintura e o pesco\u00e7o, na frente do tronco, de frente para a fonte radioativa.\u00a0Os dos\u00edmetros geralmente s\u00e3o usados \u200b\u200bna parte externa da roupa, ao redor do t\u00f3rax ou do tronco para representar a dose para o \u201ccorpo inteiro\u201d.\u00a0Dos\u00edmetros tamb\u00e9m podem ser usados \u200b\u200bnas extremidades ou perto do olho para medir a dose equivalente a esses tecidos.<\/p>\n<p>O dos\u00edmetro pode ser redefinido, geralmente ap\u00f3s uma leitura para fins de registro e, assim, reutilizado v\u00e1rias vezes.\u00a0Os EPDs t\u00eam uma tela montada na parte superior para facilitar a leitura quando eles est\u00e3o presos no bolso do peito.\u00a0O visor digital fornece informa\u00e7\u00f5es sobre\u00a0<strong>dose<\/strong>\u00a0e\u00a0<strong>taxa de dose,<\/strong>\u00a0geralmente em mSv e mSv \/ h.\u00a0O EPD possui um\u00a0<strong>alarme de taxa de dose<\/strong>\u00a0e um\u00a0<strong>alarme de dose<\/strong>\u00a0.\u00a0Esses alarmes s\u00e3o program\u00e1veis.\u00a0Diferentes alarmes podem ser definidos para diferentes atividades.<\/p>\n<p>Por exemplo:<\/p>\n<ul>\n<li>alarme de taxa de dose a 100 \u03bcSv \/ h,<\/li>\n<li>alarme de dose: 100 \u03bcSv.<\/li>\n<\/ul>\n<p><span>Se um ponto de ajuste de alarme for alcan\u00e7ado, o display relevante piscar\u00e1 junto com uma luz vermelha e ser\u00e1 gerado um ru\u00eddo agudo.\u00a0Voc\u00ea pode apagar o alarme da taxa de dose recuando para um campo de radia\u00e7\u00e3o mais baixo, mas n\u00e3o pode apagar o alarme de dose at\u00e9 chegar a um leitor de EPD.\u00a0Os EPDs tamb\u00e9m podem emitir um sinal sonoro por cada 1 ou 10 \u03bcSv que registram.\u00a0Isso fornece uma indica\u00e7\u00e3o aud\u00edvel dos campos de radia\u00e7\u00e3o.\u00a0Alguns EPDs possuem recursos de comunica\u00e7\u00e3o sem fio.\u00a0Os EPDs s\u00e3o capazes de medir uma ampla faixa de doses de radia\u00e7\u00e3o, desde n\u00edveis de rotina (\u03bcSv) at\u00e9 n\u00edveis de emerg\u00eancia (centenas de mSv ou unidades de Sieverts) com alta precis\u00e3o, e podem exibir a taxa de exposi\u00e7\u00e3o e os valores acumulados de exposi\u00e7\u00e3o.\u00a0Das tecnologias dos dos\u00edmetros, os dos\u00edmetros eletr\u00f4nicos pessoais s\u00e3o geralmente os mais caros, os maiores em tamanho e os mais vers\u00e1teis.<\/span><\/p>\n<h3><span>DMC 3000 &#8211; Mirion Technologies Inc.<\/span><\/h3>\n<p><span>O\u00a0<\/span><strong><span>DMC 3000<\/span><\/strong><span>\u00a0\u00e9 um dos\u00edmetro de radia\u00e7\u00e3o electr\u00f3nica, EPD, que fornece a dose e taxa de dose ambiente leituras para a dose de profundidade equivalente H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(10).\u00a0\u00c9 um dos EPDs mais utilizados no mercado.\u00a0Ele usa um\u00a0<strong>detector de\u00a0<\/strong><\/span><strong><span>chip Si<\/span><\/strong>\u00a0<span>com sensibilidade gama de 180 cps \/ R \/ h.\u00a0Este dos\u00edmetro pessoal eletr\u00f4nico possui as seguintes caracter\u00edsticas:<\/span><\/p>\n<ul>\n<li><span>Resposta energ\u00e9tica (raios X e gama) de 15 keV a 7 Mev.<\/span><\/li>\n<li><span>Faixa de exibi\u00e7\u00e3o da medi\u00e7\u00e3o da dose: entre 1 \u03bcSv e 10 Sv.<\/span><\/li>\n<li><span>Faixa de exibi\u00e7\u00e3o da medi\u00e7\u00e3o de taxa: entre 10 \u03bcSv \/ h e 10 Sv \/ h.<\/span><\/li>\n<\/ul>\n<p><span>O dispositivo mede 3,3 x 1,9 x 0,7 polegadas e tem op\u00e7\u00f5es para ser preso em um bolso, cinto ou cord\u00e3o.\u00a0\u00c9 alimentado por baterias recarreg\u00e1veis \u200b\u200bou AAA, com uma autonomia de at\u00e9 2.500 horas de uso cont\u00ednuo.\u00a0Indicadores sonoros e visuais sinalizam uma condi\u00e7\u00e3o de bateria fraca.\u00a0O dispositivo possui uma tela LCD de oito d\u00edgitos com luz de fundo;\u00a0navega\u00e7\u00e3o com dois bot\u00f5es;\u00a0e indicadores visuais de LED, alarmes sonoros e vibrat\u00f3rios.\u00a0A calibra\u00e7\u00e3o dever\u00e1 durar 9 meses em uso rotineiro e 2 anos em armazenamento.\u00a0Os dados s\u00e3o armazenados na mem\u00f3ria n\u00e3o vol\u00e1til.\u00a0A faixa de opera\u00e7\u00e3o do dos\u00edmetro \u00e9 de 14 \u00b0 F a 122 \u00b0 F e at\u00e9 90% de umidade relativa.\u00a0\u00c9 testado em queda para 1,5 metros.\u00a0O DMC 3000 possui m\u00f3dulos externos opcionais que expandem os recursos de detec\u00e7\u00e3o e comunica\u00e7\u00e3o do dispositivo.\u00a0Isso inclui um m\u00f3dulo beta que fornece H\u00a0<\/span><sub><span>p<\/span><\/sub><span>(0,07) para medi\u00e7\u00e3o da radia\u00e7\u00e3o beta;\u00a0um m\u00f3dulo de neutr\u00f5es que fornece H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0medi\u00e7\u00e3o de radia\u00e7\u00e3o (10) de neutr\u00f5es;\u00a0e um m\u00f3dulo de telemetria que permite a transmiss\u00e3o de dados para uma esta\u00e7\u00e3o externa.<\/span><\/p>\n<p><span>Consulte tamb\u00e9m: Os dos\u00edmetros de radia\u00e7\u00e3o para o relat\u00f3rio de pesquisa de mercado de resposta e recupera\u00e7\u00e3o.\u00a0Laborat\u00f3rio Nacional de Tecnologia de Seguran\u00e7a Urbana.\u00a0SAVER-T-MSR-4.\u00a0&lt;dispon\u00edvel em: https:\/\/www.dhs.gov\/sites\/default\/files\/publications\/Radiation-Dosimeter-Response-Recovery-MSR_0616-508_0.pdf&gt;.<\/span><\/p>\n<h2><span>Vantagens e desvantagens dos dos\u00edmetros pessoais eletr\u00f4nicos<\/span><\/h2>\n<h3><span>Vantagens dos dos\u00edmetros pessoais eletr\u00f4nicos<\/span><\/h3>\n<ul>\n<li><strong><span>Os EPDs<\/span><\/strong><span>\u00a0s\u00e3o capazes de exibir uma leitura direta da dose detectada e da taxa de dose em tempo real.<\/span><\/li>\n<li><span>Os EPDs t\u00eam um alarme de taxa de dose e um alarme de dose, que pode avisar a pessoa que o usa quando uma\u00a0<\/span><strong><span>taxa de dose especificada<\/span><\/strong><span>\u00a0ou uma\u00a0<\/span><strong><span>dose cumulativa<\/span><\/strong><span>\u00a0\u00e9 excedida.<\/span><\/li>\n<li><span>O dos\u00edmetro pode ser redefinido, geralmente ap\u00f3s uma leitura para fins de registro e, assim, reutilizado v\u00e1rias vezes.<\/span><\/li>\n<li><span>Os EPDs s\u00e3o capazes de medir uma ampla faixa de doses de radia\u00e7\u00e3o, desde n\u00edveis de rotina (\u03bcSv) at\u00e9 n\u00edveis de emerg\u00eancia (centenas de mSv ou unidades de Sieverts) com alta precis\u00e3o<\/span><\/li>\n<\/ul>\n<h3><span>Desvantagens dos Dos\u00edmetros Pessoais Eletr\u00f4nicos<\/span><\/h3>\n<ul>\n<li><span>EPDs s\u00e3o geralmente os dos\u00edmetros mais caros.<\/span><\/li>\n<li><span>EPDs geralmente s\u00e3o grandes em tamanho.<\/span><\/li>\n<li><span>Os EPDs s\u00e3o usados \u200b\u200bpara medir e registrar a exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o devido a raios gama, raios X, \u00e0s vezes part\u00edculas beta.\u00a0Para n\u00eautrons, os TLDs s\u00e3o mais capazes.<\/span><\/li>\n<\/ul>\n<h2><span>Medi\u00e7\u00e3o e monitoramento de doses de radia\u00e7\u00e3o<\/span><\/h2>\n<p><span>Nos cap\u00edtulos anteriores, descrevemos a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-equivalente-definicao\/\"><span>dose equivalente<\/span><\/a><span>\u00a0e a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva<\/span><\/a><span>\u00a0.\u00a0Mas essas doses\u00a0<\/span><strong><span>n\u00e3o<\/span><\/strong><span>\u00a0s\u00e3o\u00a0<strong>diretamente mensur\u00e1veis<\/strong>\u00a0.\u00a0Para esse fim, o ICRP introduziu e definiu um conjunto de\u00a0<\/span><strong><span>quantidades operacionais<\/span><\/strong><span>\u00a0, que podem ser medidas e cujo objetivo \u00e9 fornecer uma estimativa razo\u00e1vel para as quantidades de prote\u00e7\u00e3o.\u00a0Essas quantidades visam fornecer uma\u00a0<\/span><strong><span>estimativa conservadora<\/span><\/strong><span>\u00a0do valor das quantidades de prote\u00e7\u00e3o relacionadas a uma exposi\u00e7\u00e3o, evitando subestima\u00e7\u00e3o e superestima\u00e7\u00e3o demais.<\/span><\/p>\n<p><span>Os links num\u00e9ricos entre essas quantidades s\u00e3o representados por\u00a0<\/span><strong><span>coeficientes de convers\u00e3o<\/span><\/strong><span>\u00a0, definidos para uma pessoa de refer\u00eancia.\u00a0\u00c9 muito importante que um conjunto de coeficientes de convers\u00e3o acordado internacionalmente esteja dispon\u00edvel para uso geral nas pr\u00e1ticas de prote\u00e7\u00e3o radiol\u00f3gica para exposi\u00e7\u00f5es ocupacionais e exposi\u00e7\u00f5es do p\u00fablico.\u00a0Para o c\u00e1lculo dos coeficientes de convers\u00e3o para exposi\u00e7\u00e3o externa, fantasmas computacionais s\u00e3o usados \u200b\u200bpara avalia\u00e7\u00e3o da dose em v\u00e1rios campos de radia\u00e7\u00e3o.\u00a0Para o c\u00e1lculo dos coeficientes de dose da ingest\u00e3o de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/radionuclide-radioisotope\/\"><span>radionucl\u00eddeos<\/span><\/a><span>\u00a0, s\u00e3o utilizados modelos biokin\u00e9ticos para radionucl\u00eddeos, dados fisiol\u00f3gicos de refer\u00eancia e fantasmas computacionais.<\/span><\/p>\n<p><span>Um conjunto de dados avaliados de coeficientes de convers\u00e3o para prote\u00e7\u00e3o e quantidades operacionais para exposi\u00e7\u00e3o externa a f\u00f3ton monoenerg\u00e9tico, n\u00eautrons e radia\u00e7\u00e3o de el\u00e9trons sob condi\u00e7\u00f5es espec\u00edficas de irradia\u00e7\u00e3o \u00e9 publicado em relat\u00f3rios (ICRP, 1996b, ICRU, 1997).<\/span><\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\"><img loading=\"lazy\" class=\"alignright wp-image-25488 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\" alt=\"Monitoramento de dose de radia\u00e7\u00e3o - quantidades operacionais\" width=\"500\" height=\"156\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Dose-Monitoring-Operational-Quantities-table.png\" \/><\/a><span>Em geral, o ICRP define quantidades operacionais para\u00a0<strong>monitoramento individual<\/strong>\u00a0e de\u00a0<\/span><strong><span>\u00e1rea<\/span><\/strong><span>\u00a0de exposi\u00e7\u00f5es externas.\u00a0As quantidades operacionais para o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/area-monitoring\/\"><strong>monitoramento da \u00e1rea<\/strong><\/a>\u00a0s\u00e3o:<\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/ambient-dose-equivalent\/\"><strong><span>Dose ambiente equivalente<\/span><\/strong><\/a><span>\u00a0, H * (10).\u00a0O equivalente \u00e0 dose ambiente \u00e9 uma quantidade operacional para o monitoramento da \u00e1rea de radia\u00e7\u00e3o fortemente penetrante.<\/span><\/li>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/directional-dose-equivalent\/\"><strong><span>Dose direcional equivalente<\/span><\/strong><\/a><span>\u00a0, H &#8216;(d, \u03a9).\u00a0A dose direcional equivalente \u00e9 uma quantidade operacional para o monitoramento da \u00e1rea de radia\u00e7\u00e3o que penetra fracamente.<\/span><\/li>\n<\/ul>\n<p><span>As quantidades operacionais para\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/individual-monitoring\/\"><strong><span>monitoramento individual<\/span><\/strong><\/a><span>\u00a0s\u00e3o:<\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/personal-dose-equivalent\/\"><strong><span>Dose equivalente pessoal<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><\/a><span>\u00a0.\u00a0O<\/span><strong><span>\u00a0H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><span>\u00a0dose equivalente \u00e9 uma quantidade operacional para monitoriza\u00e7\u00e3o individual para a avalia\u00e7\u00e3o da dose para a pele e para as m\u00e3os e os p\u00e9s.<\/span><\/li>\n<li><strong><span>Dose equivalente pessoal<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0.\u00a0O\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>P<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0de dose equivalente \u00e9 uma quantidade operacional para monitoriza\u00e7\u00e3o individual para a avalia\u00e7\u00e3o da dose eficaz.<\/span><\/li>\n<\/ul>\n<p><span>Refer\u00eancia especial: ICRP, 2007. Recomenda\u00e7\u00f5es de 2007 da Comiss\u00e3o Internacional de Prote\u00e7\u00e3o Radiol\u00f3gica.\u00a0Publica\u00e7\u00e3o 103 da ICRP. Ann.\u00a0ICRP 37 (2-4).<\/span><\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min.png\"><img loading=\"lazy\" class=\"aligncenter size-large wp-image-25493 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" alt=\"Medi\u00e7\u00e3o e monitoramento de radia\u00e7\u00e3o - quantidades e limites\" width=\"1024\" height=\"600\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/><\/a><\/p>\n<h3><span>Limites de dose<\/span><\/h3>\n<p><span>Veja tamb\u00e9m:\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-limite-de-dose-radiacao-definicao\/\"><span>Limites de dose<\/span><\/a><\/p>\n<p><span>Os limites de dose s\u00e3o divididos em dois grupos, o p\u00fablico e os trabalhadores expostos ocupacionalmente.\u00a0De acordo com o ICRP, a exposi\u00e7\u00e3o ocupacional refere-se a toda a exposi\u00e7\u00e3o incorrida pelos trabalhadores no curso de seu trabalho, com exce\u00e7\u00e3o da<\/span><\/p>\n<ol>\n<li><span>exposi\u00e7\u00f5es exclu\u00eddas e exposi\u00e7\u00f5es de atividades isentas que envolvam radia\u00e7\u00e3o ou fontes isentas<\/span><\/li>\n<li><span>qualquer exposi\u00e7\u00e3o m\u00e9dica<\/span><\/li>\n<li><span>a radia\u00e7\u00e3o natural local normal de fundo.<\/span><\/li>\n<\/ol>\n<p><span>A tabela a seguir resume os limites de dose para trabalhadores expostos ocupacionalmente e para o p\u00fablico:<\/span><\/p>\n<figure id=\"attachment_25487\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-25487\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\"><img loading=\"lazy\" class=\"size-full wp-image-25487 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\" alt=\"limites de dose - radia\u00e7\u00e3o\" width=\"628\" height=\"207\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-limits-radiation.png\" \/><\/a><figcaption id=\"caption-attachment-25487\" class=\"wp-caption-text\"><span>Tabela de limites de dose para trabalhadores expostos ocupacionalmente e para o p\u00fablico.<\/span><br \/>\n<span>Fonte dos dados: ICRP, 2007. Recomenda\u00e7\u00f5es de 2007 da Comiss\u00e3o Internacional de Prote\u00e7\u00e3o Radiol\u00f3gica.\u00a0Publica\u00e7\u00e3o 103 da ICRP. Ann.\u00a0ICRP 37 (2-4).<\/span><\/figcaption><\/figure>\n<p><span>De acordo com a recomenda\u00e7\u00e3o do ICRP em sua declara\u00e7\u00e3o sobre rea\u00e7\u00f5es teciduais de 21 de abril de 2011, o limite de dose equivalente para a lente do olho para exposi\u00e7\u00e3o ocupacional em situa\u00e7\u00f5es de exposi\u00e7\u00e3o planejada foi reduzido de 150 mSv \/ ano para 20 mSv \/ ano, em m\u00e9dia por per\u00edodos definidos de 5 anos, sem dose anual em um \u00fanico ano superior a 50 mSv.<\/span><\/p>\n<p><span>Os limites da\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva<\/span><\/a><span>\u00a0s\u00e3o a soma das doses efetivas relevantes da exposi\u00e7\u00e3o externa no per\u00edodo especificado e a\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-comprometida-dose-efetiva-comprometida-definicao\/\"><span>dose efetiva comprometida<\/span><\/a><span>\u00a0da ingest\u00e3o de radionucl\u00eddeos no mesmo per\u00edodo.\u00a0Para adultos, a dose efetiva comprometida \u00e9 calculada por um per\u00edodo de 50 anos ap\u00f3s a ingest\u00e3o, enquanto que para crian\u00e7as \u00e9 calculada para o per\u00edodo de at\u00e9 70 anos.\u00a0O limite efetivo da dose para o corpo inteiro de 20 mSv \u00e9 um valor m\u00e9dio em cinco anos.\u00a0O limite real \u00e9 de 100 mSv em 5 anos, com n\u00e3o mais de 50 mSv em um ano.<\/span><\/p>\n<h2><span>Sievert &#8211; Unidade de Dose Equivalente<\/span><\/h2>\n<p><span>Na prote\u00e7\u00e3o contra radia\u00e7\u00e3o, o\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-sievert-unidade-de-dose-equivalente-definicao\/\"><strong><span>sievert<\/span><\/strong><\/a><span>\u00a0\u00e9 uma unidade derivada de\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-equivalente-definicao\/\"><strong><span>dose equivalente<\/span><\/strong><\/a><span>\u00a0e\u00a0<\/span><strong><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-dose-eficaz-definicao\/\"><span>dose efetiva<\/span><\/a><span>\u00a0.\u00a0<\/span><\/strong><span>O sievert representa o efeito biol\u00f3gico equivalente ao dep\u00f3sito de um joule de energia de raios gama em um quilograma de tecido humano.\u00a0A unidade de sievert \u00e9 importante na prote\u00e7\u00e3o contra radia\u00e7\u00e3o e recebeu o nome do cientista sueco Rolf Sievert, que fez muitos dos primeiros trabalhos sobre dosimetria de radia\u00e7\u00e3o em terapia de radia\u00e7\u00e3o.<\/span><\/p>\n<p><span>Como foi escrito, o sievert \u00e9 usado para quantidades de dose de radia\u00e7\u00e3o, como dose equivalente e dose efetiva.\u00a0<\/span><strong><span>Dose equivalente<\/span><\/strong><span>\u00a0(s\u00edmbolo\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>T<\/span><\/sub><\/strong><strong><span>\u00a0)<\/span><\/strong><span>\u00a0\u00e9 uma quantidade de dose calculada para \u00f3rg\u00e3os individuais (\u00edndice T &#8211; tecido).\u00a0<\/span><strong><span>A dose equivalente<\/span><\/strong><span>\u00a0\u00e9 baseada na dose absorvida para um \u00f3rg\u00e3o, ajustada para levar em conta a\u00a0<\/span><strong><span>efic\u00e1cia do tipo de radia\u00e7\u00e3o<\/span><\/strong><span>\u00a0.\u00a0Dose equivalente \u00e9 dada a s\u00edmbolo H\u00a0<\/span><sub><span>t<\/span><\/sub><span>\u00a0.\u00a0A unidade SI de\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>t<\/span><\/sub><\/strong><span>\u00a0\u00e9 o\u00a0<\/span><strong><span>Sievert<\/span><\/strong><span>\u00a0(Sv) ou mas REM (\u00a0<\/span><a href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-roentgen-equivalent-man-rem-unit-definition\/\"><span>homem equivalente roentgen<\/span><\/a><span>\u00a0) ainda \u00e9 vulgarmente utilizado (\u00a0<\/span><strong><span>1 Sv = 100 REM<\/span><\/strong><span>\u00a0).<\/span><\/p>\n<h3><span>Exemplos de doses em Sieverts<\/span><\/h3>\n<p><span>Devemos notar que a\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/\"><span>radia\u00e7\u00e3o<\/span><\/a><span>\u00a0est\u00e1 \u00e0 nossa volta.\u00a0Dentro, ao redor e acima do mundo em que vivemos. \u00c9 uma for\u00e7a de energia natural que nos rodeia.\u00a0\u00c9 uma parte do nosso mundo natural que est\u00e1 aqui desde o nascimento do nosso planeta.\u00a0Nos pontos a seguir, tentamos expressar enormes faixas de exposi\u00e7\u00e3o \u00e0 radia\u00e7\u00e3o, que podem ser obtidas de v\u00e1rias fontes.<\/span><\/p>\n<ul>\n<li><strong><span>0,05 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dormindo ao lado de algu\u00e9m<\/span><\/li>\n<li><strong><span>0,09 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Morando a 48 quil\u00f4metros de uma usina nuclear por um ano<\/span><\/li>\n<li><strong><span>0,1 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Comendo uma banana<\/span><\/li>\n<li><strong><span>0,3 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Morando a 80 quil\u00f4metros de uma usina a carv\u00e3o por um ano<\/span><\/li>\n<li><strong><span>10 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia di\u00e1ria recebida do fundo natural<\/span><\/li>\n<li><strong><span>20 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; radiografia de t\u00f3rax<\/span><\/li>\n<li><strong><span>40 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Um voo de avi\u00e3o de 5 horas<\/span><\/li>\n<li><strong><span>600 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; mamografia<\/span><\/li>\n<li><strong><span>1 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Limite de dose para membros individuais do p\u00fablico, dose efetiva total por ano<\/span><\/li>\n<li><strong><span>3 650 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia anual recebida do fundo natural<\/span><\/li>\n<li><strong><span>5 800 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; tomografia computadorizada do t\u00f3rax<\/span><\/li>\n<li><strong><span>10 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose m\u00e9dia anual recebida do ambiente natural em Ramsar, Ir\u00e3<\/span><\/li>\n<li><strong><span>20 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; tomografia computadorizada de corpo inteiro<\/span><\/li>\n<li><strong><span>175 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose anual de radia\u00e7\u00e3o natural em uma praia de monazita perto de Guarapari, Brasil.<\/span><\/li>\n<li><strong><span>5 000 000 \u00b5Sv<\/span><\/strong><span>\u00a0&#8211; Dose que mata um ser humano com um risco de 50% dentro de 30 dias (LD50 \/ 30), se a dose for recebida por um per\u00edodo\u00a0<\/span><strong><span>muito curto<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Um dos\u00edmetro pessoal eletr\u00f4nico, EPD, \u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da dose cumulativa e da taxa de dose atual e pode avisar a pessoa que o usa.\u00a0Dosimetria de Radia\u00e7\u00e3o Um\u00a0dos\u00edmetro pessoal eletr\u00f4nico\u00a0\u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da\u00a0dose cumulativa\u00a0e da\u00a0taxa de dose atual\u00a0e pode avisar a &#8230; <a title=\"O que \u00e9 EPD &#8211; Dos\u00edmetro pessoal eletr\u00f4nico &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/\" aria-label=\"More on O que \u00e9 EPD &#8211; Dos\u00edmetro pessoal eletr\u00f4nico &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 EPD - Dos\u00edmetro pessoal eletr\u00f4nico - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"Um dos\u00edmetro pessoal eletr\u00f4nico, EPD, \u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da dose cumulativa e da taxa de dose atual e pode avisar a pessoa que o usa. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 EPD - Dos\u00edmetro pessoal eletr\u00f4nico - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"Um dos\u00edmetro pessoal eletr\u00f4nico, EPD, \u00e9 um dos\u00edmetro moderno, que pode fornecer uma leitura cont\u00ednua da dose cumulativa e da taxa de dose atual e pode avisar a pessoa que o usa. Dosimetria de Radia\u00e7\u00e3o\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-14T00:35:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-20T11:37:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/EPD-electronic-personal-dosimeter.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"10 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/EPD-electronic-personal-dosimeter.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/\",\"name\":\"O que \\u00e9 EPD - Dos\\u00edmetro pessoal eletr\\u00f4nico - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/#primaryimage\"},\"datePublished\":\"2020-06-14T00:35:39+00:00\",\"dateModified\":\"2020-07-20T11:37:37+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Um dos\\u00edmetro pessoal eletr\\u00f4nico, EPD, \\u00e9 um dos\\u00edmetro moderno, que pode fornecer uma leitura cont\\u00ednua da dose cumulativa e da taxa de dose atual e pode avisar a pessoa que o usa. Dosimetria de Radia\\u00e7\\u00e3o\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-epd-dosimetro-pessoal-eletronico-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17449"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=17449"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17449\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=17449"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=17449"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=17449"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}