{"id":21380,"date":"2020-07-16T06:03:35","date_gmt":"2020-07-16T06:03:35","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/quest-ce-que-lattenuation-des-rayons-x-definition\/"},"modified":"2020-07-16T06:03:35","modified_gmt":"2020-07-16T06:03:35","slug":"quest-ce-que-lattenuation-des-rayons-x-definition","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/","title":{"rendered":"Qu&rsquo;est-ce que l&rsquo;att\u00e9nuation des rayons X &#8211; D\u00e9finition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">La th\u00e9orie de l&rsquo;att\u00e9nuation des rayons X d\u00e9crit comment les rayons X sont att\u00e9nu\u00e9s par les mat\u00e9riaux.\u00a0La th\u00e9orie de l&rsquo;att\u00e9nuation est \u00e9galement valable pour les rayons X et les rayons gamma.\u00a0Dosim\u00e9trie des rayonnements<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p><strong>Les rayons X<\/strong>\u00a0, \u00e9galement connus sous le nom\u00a0<strong>de rayonnement X<\/strong>\u00a0, se r\u00e9f\u00e8rent au rayonnement \u00e9lectromagn\u00e9tique (pas de masse au repos, pas de charge) des hautes \u00e9nergies.\u00a0Les rayons X sont des\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/photon\/\">photons de<\/a>\u00a0haute \u00e9nergie\u00a0avec des longueurs d&rsquo;onde courtes et donc des fr\u00e9quences tr\u00e8s \u00e9lev\u00e9es.\u00a0La fr\u00e9quence de rayonnement est un param\u00e8tre cl\u00e9 de tous les photons, car elle d\u00e9termine l&rsquo;\u00e9nergie d&rsquo;un photon.\u00a0Les photons sont class\u00e9s en fonction des \u00e9nergies des ondes radio\u00e9lectriques de faible \u00e9nergie et du rayonnement infrarouge, \u00e0 travers la lumi\u00e8re visible, aux rayons X \u00e0 haute \u00e9nergie et aux\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/photon\/gamma-ray\/\">rayons gamma<\/a>\u00a0.<\/p>\n<p>La plupart des rayons X ont une longueur d&rsquo;onde allant de 0,01 \u00e0 10 nanom\u00e8tres (3 \u00d7 10\u00a0<sup>16<\/sup>\u00a0Hz \u00e0 3 \u00d7 10\u00a0<sup>19<\/sup>\u00a0Hz), correspondant \u00e0 des \u00e9nergies comprises entre 100 eV et 100 keV.\u00a0Les longueurs d&rsquo;onde des rayons X sont plus courtes que celles des rayons UV et g\u00e9n\u00e9ralement plus longues que celles des rayons gamma.\u00a0La distinction entre les rayons X et les rayons gamma n&rsquo;est pas si simple et a chang\u00e9 au cours des derni\u00e8res d\u00e9cennies.\u00a0Selon la d\u00e9finition actuellement valable, les\u00a0<strong>rayons X sont \u00e9mis par des \u00e9lectrons<\/strong>\u00a0\u00e0 l&rsquo;ext\u00e9rieur du noyau, tandis que\u00a0<strong>les rayons gamma sont \u00e9mis par le noyau<\/strong>\u00a0.<\/p>\n<h2>Att\u00e9nuation des rayons X<\/h2>\n<figure id=\"attachment_11684\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-11684\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/total_photon_attenuation.png\"><img loading=\"lazy\" class=\"size-medium wp-image-11684 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/total_photon_attenuation-300x217.png\" alt=\"Coefficients d'att\u00e9nuation.\" width=\"300\" height=\"217\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/total_photon_attenuation-300x217.png\" \/><\/a><figcaption id=\"caption-attachment-11684\" class=\"wp-caption-text\">Sections efficaces totales de photons.<br \/>\nSource: Wikimedia Commons<\/figcaption><\/figure>\n<p>\u00c0 mesure que les\u00a0<strong>photons de haute \u00e9nergie<\/strong>\u00a0traversent le mat\u00e9riau, leur \u00e9nergie diminue.\u00a0C&rsquo;est ce qu&rsquo;on appelle l&rsquo;\u00a0<strong>att\u00e9nuation<\/strong>\u00a0.\u00a0La th\u00e9orie de l&rsquo;att\u00e9nuation est \u00e9galement valable pour les\u00a0<strong>rayons X<\/strong>\u00a0et\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/fundamental-particles\/photon\/gamma-ray\/\"><strong>les rayons gamma<\/strong><\/a>\u00a0.\u00a0Il s&rsquo;av\u00e8re que les photons de plus haute \u00e9nergie (rayons X durs) voyagent \u00e0 travers les tissus plus facilement que les photons de basse \u00e9nergie (c&rsquo;est-\u00e0-dire que les photons de plus haute \u00e9nergie sont moins susceptibles d&rsquo;interagir avec la mati\u00e8re).\u00a0Une grande partie de cet effet est li\u00e9e \u00e0 l&rsquo;\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/interaction-radiation-matter\/interaction-gamma-radiation-matter\/photoelectric-effect\/\">effet photo\u00e9lectrique<\/a>\u00a0.\u00a0La probabilit\u00e9 d&rsquo;absorption photo\u00e9lectrique est approximativement proportionnelle \u00e0 (Z \/ E)\u00a0<sup>3<\/sup>, o\u00f9 Z est le num\u00e9ro atomique de l&rsquo;atome de tissu et E est l&rsquo;\u00e9nergie photonique.\u00a0\u00c0 mesure que E augmente, la probabilit\u00e9 d&rsquo;interaction diminue rapidement.\u00a0Pour les \u00e9nergies sup\u00e9rieures, la diffusion Compton devient dominante.\u00a0La diffusion de Compton est \u00e0 peu pr\u00e8s constante pour diff\u00e9rentes \u00e9nergies bien qu&rsquo;elle diminue lentement aux \u00e9nergies plus \u00e9lev\u00e9es.<\/p>\n<h3>Att\u00e9nuation exponentielle<\/h3>\n<p>Supposons que les\u00a0<strong>rayons X mono\u00e9nerg\u00e9tiques<\/strong>\u00a0sont collimat\u00e9s en un\u00a0<strong>faisceau \u00e9troit<\/strong>\u00a0et que le d\u00e9tecteur derri\u00e8re le mat\u00e9riau d\u00e9tecte uniquement les rayons X qui ont travers\u00e9 ce mat\u00e9riau sans aucune sorte d&rsquo;interaction avec ce mat\u00e9riau, alors la d\u00e9pendance devrait \u00eatre une simple\u00a0<strong>att\u00e9nuation exponentielle des rayons X<\/strong>\u00a0.\u00a0Chacune de ces interactions \u00e9limine le photon du faisceau soit par absorption, soit par diffusion loin de la direction du d\u00e9tecteur.\u00a0Par cons\u00e9quent, les interactions peuvent \u00eatre caract\u00e9ris\u00e9es par une probabilit\u00e9 fixe d&rsquo;occurrence par unit\u00e9 de longueur de trajet dans l&rsquo;absorbeur.\u00a0La somme de ces probabilit\u00e9s est appel\u00e9e\u00a0<strong>coefficient d&rsquo;att\u00e9nuation lin\u00e9aire<\/strong>\u00a0:<\/p>\n<p><strong>\u03bc = \u03c4\u00a0<sub>(photo\u00e9lectrique)<\/sub>\u00a0+ \u03c3\u00a0<sub>(Compton)<\/sub><br \/>\n<\/strong><\/p>\n<figure id=\"attachment_11791\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-11791\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/attenuation.png\"><img loading=\"lazy\" class=\"size-full wp-image-11790 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/attenuation.png\" alt=\"Att\u00e9nuation des rayons gamma\" width=\"570\" height=\"357\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/attenuation.png\" \/><\/a><figcaption id=\"caption-attachment-11791\" class=\"wp-caption-text\">L&rsquo;importance relative de divers processus d&rsquo;interaction du rayonnement gamma avec la mati\u00e8re.<\/figcaption><\/figure>\n<h2>Coefficient d&rsquo;att\u00e9nuation lin\u00e9aire &#8211; rayons X<\/h2>\n<p><span>L&rsquo;att\u00e9nuation des rayons X peut alors \u00eatre d\u00e9crite par l&rsquo;\u00e9quation suivante.<\/span><\/p>\n<p><strong><span>I = I\u00a0<\/span><sub><span>0<\/span><\/sub><span>\u00a0.e\u00a0<\/span><sup><span>-\u03bcx<\/span><\/sup><\/strong><\/p>\n<p><span>, o\u00f9 I est l&rsquo;intensit\u00e9 apr\u00e8s att\u00e9nuation, I\u00a0<\/span><sub><span>o<\/span><\/sub><span>\u00a0est l&rsquo;intensit\u00e9 incidente, \u03bc est le coefficient d&rsquo;att\u00e9nuation lin\u00e9aire (cm\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0) et l&rsquo;\u00e9paisseur physique de l&rsquo;absorbeur (cm).<\/span><\/p>\n<figure id=\"attachment_11792\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-11792\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/exponential-attenuation.png\"><img loading=\"lazy\" class=\"size-medium wp-image-11790 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/exponential-attenuation-300x217.png\" alt=\"Att\u00e9nuation\" width=\"300\" height=\"217\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/exponential-attenuation-300x217.png\" \/><\/a><figcaption id=\"caption-attachment-11792\" class=\"wp-caption-text\"><span>D\u00e9pendance de l&rsquo;intensit\u00e9 du rayonnement gamma sur l&rsquo;\u00e9paisseur de l&rsquo;absorbeur<\/span><\/figcaption><\/figure>\n<p><span>Les mat\u00e9riaux r\u00e9pertori\u00e9s dans le tableau sont l&rsquo;air, l&rsquo;eau et diff\u00e9rents \u00e9l\u00e9ments du carbone (\u00a0<\/span><i><span>Z<\/span><\/i><span>\u00a0= 6) au plomb (\u00a0<\/span><i><span>Z<\/span><\/i><span>\u00a0= 82) et leurs coefficients d&rsquo;att\u00e9nuation lin\u00e9aires sont donn\u00e9s pour deux \u00e9nergies de rayons X.\u00a0Il existe deux caract\u00e9ristiques principales du coefficient d&rsquo;att\u00e9nuation lin\u00e9aire:<\/span><\/p>\n<ul>\n<li><span>Le coefficient d&rsquo;att\u00e9nuation lin\u00e9aire augmente \u00e0 mesure que le num\u00e9ro atomique de l&rsquo;absorbeur augmente.<\/span><\/li>\n<li><span>Le coefficient d&rsquo;att\u00e9nuation lin\u00e9aire pour tous les mat\u00e9riaux diminue avec l&rsquo;\u00e9nergie des rayons X.<\/span><\/li>\n<\/ul>\n<h2><span>Demi couche de valeur<\/span><\/h2>\n<p><span>La couche \u00e0 demi-valeur exprime l&rsquo;\u00e9paisseur du mat\u00e9riau absorbant n\u00e9cessaire pour r\u00e9duire l&rsquo;intensit\u00e9 du rayonnement incident d&rsquo;un\u00a0<\/span><strong><span>facteur deux<\/span><\/strong><span>\u00a0.\u00a0Il existe deux caract\u00e9ristiques principales de la couche de demi-valeur:<\/span><\/p>\n<ul>\n<li><span>La\u00a0<\/span><b><span>couche de demi-valeur<\/span><\/b><span>\u00a0diminue \u00e0 mesure que le num\u00e9ro atomique de l&rsquo;absorbeur augmente.\u00a0Par exemple, 35 m d&rsquo;air sont n\u00e9cessaires pour r\u00e9duire l&rsquo;intensit\u00e9 d&rsquo;un faisceau de rayons X de 100 keV par un facteur de deux alors que seulement 0,12 mm de plomb peut faire la m\u00eame chose.<\/span><\/li>\n<li><span>La\u00a0<\/span><b><span>couche<\/span><\/b><span>\u00a0de\u00a0<b>demi-valeur<\/b>\u00a0pour tous les mat\u00e9riaux augmente avec l&rsquo;\u00e9nergie des rayons X.\u00a0Par exemple, de 0,26 cm pour le fer \u00e0 100 keV \u00e0 environ 0,64 cm \u00e0 200 keV.<\/span><\/li>\n<\/ul>\n<h2><span>Coefficient d&rsquo;att\u00e9nuation de masse<\/span><\/h2>\n<p><span>Lors de la caract\u00e9risation d&rsquo;un mat\u00e9riau absorbant, on peut parfois utiliser le coefficient d&rsquo;att\u00e9nuation massique. \u00a0<\/span><strong><span>Le coefficient d&rsquo;att\u00e9nuation massique<\/span><\/strong><span>\u00a0est d\u00e9fini comme le rapport du coefficient d&rsquo;att\u00e9nuation lin\u00e9aire et de la densit\u00e9 d&rsquo;absorbeur\u00a0<\/span><strong><span>(\u03bc \/ \u03c1)<\/span><\/strong><span>\u00a0.\u00a0L&rsquo;\u00a0<\/span><strong><span>att\u00e9nuation des rayons X<\/span><\/strong><span>\u00a0peut alors \u00eatre d\u00e9crite par l&rsquo;\u00e9quation suivante:<\/span><\/p>\n<p><strong><span>I = I\u00a0<\/span><sub><span>0<\/span><\/sub><span>\u00a0.e\u00a0<\/span><sup><span>&#8211; (\u03bc \/ \u03c1) .\u03c1l<\/span><\/sup><\/strong><\/p>\n<p><span>, o\u00f9 \u03c1 est la densit\u00e9 du mat\u00e9riau, (\u03bc \/ \u03c1) est le coefficient d&rsquo;att\u00e9nuation de la masse et \u03c1.l est l&rsquo;\u00e9paisseur de la masse.\u00a0L&rsquo;unit\u00e9 de mesure utilis\u00e9e pour le coefficient d&rsquo;att\u00e9nuation de masse cm\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0g\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0.\u00a0Pour les \u00e9nergies interm\u00e9diaires, la diffusion Compton domine et diff\u00e9rents absorbeurs ont\u00a0<\/span><strong><span>des coefficients d&rsquo;att\u00e9nuation de masse<\/span><\/strong><span>\u00a0approximativement \u00e9gaux\u00a0.\u00a0Cela est d\u00fb au fait que la section efficace de la diffusion Compton est proportionnelle au Z (num\u00e9ro atomique) et donc le coefficient est proportionnel \u00e0 la densit\u00e9 du mat\u00e9riau \u03c1.\u00a0Aux petites valeurs de l&rsquo;\u00e9nergie des rayons X, o\u00f9 le coefficient est proportionnel aux puissances sup\u00e9rieures du num\u00e9ro atomique Z (pour l&rsquo;effet photo\u00e9lectrique \u03c3\u00a0<\/span><sub><span>f<\/span><\/sub><span>\u00a0~ Z\u00a0<\/span><sup><span>3<\/span><\/sup><span>\u00a0), le coefficient d&rsquo;att\u00e9nuation \u03bc n&rsquo;est pas une constante.<\/span><\/p>\n<p><span>Voir aussi calculatrice:\u00a0\u00a0<\/span><a href=\"http:\/\/www.radprocalculator.com\/Gamma.aspx\"><span>Activit\u00e9 gamma au d\u00e9bit de dose (avec \/ sans \u00e9cran)<\/span><\/a><\/p>\n<p><span>Voir aussi XCOM &#8211; photon cross-section DB:\u00a0\u00a0<\/span><a href=\"http:\/\/www.nist.gov\/pml\/data\/xcom\/\"><span>XCOM: Photon Cross Sections Database<\/span><\/a><\/p>\n<h2><span>Exemple:<\/span><\/h2>\n<p><span>De quelle quantit\u00e9 d&rsquo;eau absorbez-vous la chaleur si vous souhaitez r\u00e9duire l&rsquo;intensit\u00e9 d&rsquo;un\u00a0faisceau de rayons X\u00a0<\/span><strong><span>mono\u00e9nerg\u00e9tique de<\/span><\/strong><span>\u00a0100 keV\u00a0(\u00a0<\/span><strong><span>faisceau \u00e9troit<\/span><\/strong><span>\u00a0) \u00e0\u00a0<\/span><strong><span>1%<\/span><\/strong><span>\u00a0de son intensit\u00e9 incidente?\u00a0La couche de demi-valeur pour les rayons X \u00e0 100 keV dans l&rsquo;eau est de 4,15 cm et le coefficient d&rsquo;att\u00e9nuation lin\u00e9aire pour les rayons X \u00e0 100 keV dans l&rsquo;eau est de 0,167 cm\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0.\u00a0Le probl\u00e8me est assez simple et peut \u00eatre d\u00e9crit par l&rsquo;\u00e9quation suivante:<\/span><\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25213 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-equation.png\" alt=\"\" width=\"116\" height=\"62\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-equation.png\" \/><\/a><span>Si la demi-couche de valeur pour l&rsquo;eau est de 4,15 cm, le coefficient d&rsquo;att\u00e9nuation lin\u00e9aire est:<\/span><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/linear-attenuation-example.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25212 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/linear-attenuation-example.png\" alt=\"\" width=\"196\" height=\"63\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/linear-attenuation-example.png\" \/><\/a><span>Maintenant, nous pouvons utiliser l&rsquo;\u00e9quation d&rsquo;att\u00e9nuation exponentielle:<\/span><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-problem-with-solution.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25211 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-problem-with-solution.png\" alt=\"att\u00e9nuation des rayons X - probl\u00e8me avec la solution\" width=\"238\" height=\"225\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/x-ray-attenuation-problem-with-solution.png\" \/><\/a><\/p>\n<p><span>L&rsquo;\u00e9paisseur d&rsquo;eau requise est donc d&rsquo;environ\u00a0<\/span><strong><span>27,58 cm<\/span><\/strong><span>\u00a0.\u00a0C&rsquo;est une \u00e9paisseur relativement importante et elle est caus\u00e9e par de petits nombres atomiques d&rsquo;hydrog\u00e8ne et d&rsquo;oxyg\u00e8ne.\u00a0Si nous calculons le m\u00eame probl\u00e8me pour le\u00a0<\/span><strong><span>plomb (Pb)<\/span><\/strong><span>\u00a0, nous obtenons l&rsquo;\u00e9paisseur\u00a0<\/span><strong><span>x = 0,077 cm<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><strong><span>Coefficients d&rsquo;att\u00e9nuation lin\u00e9aire<\/span><\/strong><\/p>\n<p><strong><span>Tableau des coefficients d&rsquo;att\u00e9nuation lin\u00e9aire<\/span><\/strong><span>\u00a0(en cm\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0) pour diff\u00e9rents mat\u00e9riaux \u00e0 des \u00e9nergies de photons de 100, 200 et 500 keV.<\/span><\/p>\n<table rules=\"rows\">\n<tbody>\n<tr>\n<td><span>Absorbeur<\/span><\/td>\n<td><span>100 keV<\/span><\/td>\n<td><span>200 keV<\/span><\/td>\n<td><span>500 keV<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Air<\/span><\/td>\n<td><span>\u00a0 0,000195 \/ cm<\/span><\/td>\n<td><span>\u00a0 0,000159 \/ cm<\/span><\/td>\n<td><span>\u00a0 0,000112 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Eau<\/span><\/td>\n<td><span>0,167 \/ cm<\/span><\/td>\n<td><span>0,136 \/ cm<\/span><\/td>\n<td><span>0,097 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Carbone<\/span><\/td>\n<td><span>0,335 \/ cm<\/span><\/td>\n<td><span>0,274 \/ cm<\/span><\/td>\n<td><span>0,196 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Aluminium<\/span><\/td>\n<td><span>0,435 \/ cm<\/span><\/td>\n<td><span>0,324 \/ cm<\/span><\/td>\n<td><span>0,227 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Le fer<\/span><\/td>\n<td><span>2,72 \/ cm<\/span><\/td>\n<td><span>1,09 \/ cm<\/span><\/td>\n<td><span>0,655 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Cuivre<\/span><\/td>\n<td><span>3,8 \/ cm<\/span><\/td>\n<td><span>1,309 \/ cm<\/span><\/td>\n<td><span>0,73 \/ cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Conduire<\/span><\/td>\n<td><span>59,7 \/ cm<\/span><\/td>\n<td><span>10,15 \/ cm<\/span><\/td>\n<td><span>1,64 \/ cm<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span id=\"more-156\"><\/span><strong><span>Demi couches de valeur<\/span><\/strong><\/p>\n<p><strong><span>Tableau des demi-couches de valeur<\/span><\/strong><span>\u00a0(en cm) pour diff\u00e9rents mat\u00e9riaux \u00e0 des \u00e9nergies de photons de 100, 200 et 500 keV.<\/span><\/p>\n<table rules=\"rows\">\n<tbody>\n<tr>\n<td><span>Absorbeur<\/span><\/td>\n<td><span>100 keV<\/span><\/td>\n<td><span>200 keV<\/span><\/td>\n<td><span>500 keV<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Air<\/span><\/td>\n<td><span>3555 cm<\/span><\/td>\n<td><span>4359 cm<\/span><\/td>\n<td><span>6189 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Eau<\/span><\/td>\n<td><span>4,15 cm<\/span><\/td>\n<td><span>5,1 cm<\/span><\/td>\n<td><span>7.15 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Carbone<\/span><\/td>\n<td><span>2,07 cm<\/span><\/td>\n<td><span>2,53 cm<\/span><\/td>\n<td><span>3,54 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Aluminium<\/span><\/td>\n<td><span>1,59 cm<\/span><\/td>\n<td><span>2,14 cm<\/span><\/td>\n<td><span>3,05 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Le fer<\/span><\/td>\n<td><span>0,26 cm<\/span><\/td>\n<td><span>0,64 cm<\/span><\/td>\n<td><span>1,06 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Cuivre<\/span><\/td>\n<td><span>0,18 cm<\/span><\/td>\n<td><span>0,53 cm<\/span><\/td>\n<td><span>0,95 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span>Conduire<\/span><\/td>\n<td><span>\u00a00,012 cm<\/span><\/td>\n<td><span>\u00a00,068 cm<\/span><\/td>\n<td><span>\u00a00,42 cm<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span>Validit\u00e9 de la loi exponentielle<\/span><\/h2>\n<p><span>La loi exponentielle d\u00e9crira toujours l&rsquo;att\u00e9nuation du rayonnement primaire par la mati\u00e8re.\u00a0Si des particules secondaires sont produites ou si le rayonnement primaire change d&rsquo;\u00e9nergie ou de direction, alors l&rsquo;att\u00e9nuation effective sera bien moindre.\u00a0Le rayonnement p\u00e9n\u00e9trera plus profond\u00e9ment dans la mati\u00e8re que ne le pr\u00e9voit la seule loi exponentielle.\u00a0Le processus doit \u00eatre pris en compte lors de l&rsquo;\u00e9valuation de l&rsquo;effet du blindage contre les radiations.<\/span><\/p>\n<figure id=\"attachment_11803\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-11803\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/secondary_length.png\"><img loading=\"lazy\" class=\"size-medium wp-image-11802 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/secondary_length-300x165.png\" alt=\"Exemple d'accumulation de particules secondaires.  D\u00e9pend fortement du caract\u00e8re et des param\u00e8tres des particules primaires.\" width=\"300\" height=\"165\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/secondary_length-300x165.png\" \/><\/a><figcaption id=\"caption-attachment-11803\" class=\"wp-caption-text\"><span>Exemple d&rsquo;accumulation de particules secondaires.\u00a0D\u00e9pend fortement du caract\u00e8re et des param\u00e8tres des particules primaires.<\/span><\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Cet article est bas\u00e9 sur la traduction automatique de l&rsquo;article original en anglais. Pour plus d&rsquo;informations, voir l&rsquo;article en anglais. Pouvez vous nous aider Si vous souhaitez corriger la traduction, envoyez-la \u00e0 l&rsquo;adresse: translations@nuclear-power.com ou remplissez le formulaire de traduction en ligne. Nous appr\u00e9cions votre aide, nous mettrons \u00e0 jour la traduction le plus rapidement possible. Merci<\/p>\n","protected":false},"excerpt":{"rendered":"<p>La th\u00e9orie de l&rsquo;att\u00e9nuation des rayons X d\u00e9crit comment les rayons X sont att\u00e9nu\u00e9s par les mat\u00e9riaux.\u00a0La th\u00e9orie de l&rsquo;att\u00e9nuation est \u00e9galement valable pour les rayons X et les rayons gamma.\u00a0Dosim\u00e9trie des rayonnements Les rayons X\u00a0, \u00e9galement connus sous le nom\u00a0de rayonnement X\u00a0, se r\u00e9f\u00e8rent au rayonnement \u00e9lectromagn\u00e9tique (pas de masse au repos, pas de &#8230; <a title=\"Qu&rsquo;est-ce que l&rsquo;att\u00e9nuation des rayons X &#8211; D\u00e9finition\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/\" aria-label=\"En savoir plus sur Qu&rsquo;est-ce que l&rsquo;att\u00e9nuation des rayons X &#8211; D\u00e9finition\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[49],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu&#039;est-ce que l&#039;att\u00e9nuation des rayons X - D\u00e9finition<\/title>\n<meta name=\"description\" content=\"La th\u00e9orie de l&#039;att\u00e9nuation des rayons X d\u00e9crit comment les rayons X sont att\u00e9nu\u00e9s par les mat\u00e9riaux. La th\u00e9orie de l&#039;att\u00e9nuation est \u00e9galement valable pour les rayons X et les rayons gamma. Dosim\u00e9trie des rayonnements\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu&#039;est-ce que l&#039;att\u00e9nuation des rayons X - D\u00e9finition\" \/>\n<meta property=\"og:description\" content=\"La th\u00e9orie de l&#039;att\u00e9nuation des rayons X d\u00e9crit comment les rayons X sont att\u00e9nu\u00e9s par les mat\u00e9riaux. La th\u00e9orie de l&#039;att\u00e9nuation est \u00e9galement valable pour les rayons X et les rayons gamma. Dosim\u00e9trie des rayonnements\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-16T06:03:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/total_photon_attenuation-300x217.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"6 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"\",\"caption\":\"Sections efficaces totales de photons. Source: Wikimedia Commons\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/\",\"name\":\"Qu'est-ce que l'att\\u00e9nuation des rayons X - D\\u00e9finition\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/#primaryimage\"},\"datePublished\":\"2020-07-16T06:03:35+00:00\",\"dateModified\":\"2020-07-16T06:03:35+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"La th\\u00e9orie de l'att\\u00e9nuation des rayons X d\\u00e9crit comment les rayons X sont att\\u00e9nu\\u00e9s par les mat\\u00e9riaux. La th\\u00e9orie de l'att\\u00e9nuation est \\u00e9galement valable pour les rayons X et les rayons gamma. Dosim\\u00e9trie des rayonnements\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/fr\/quest-ce-que-lattenuation-des-rayons-x-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/posts\/21380"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/comments?post=21380"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/posts\/21380\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/media?parent=21380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/categories?post=21380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/fr\/wp-json\/wp\/v2\/tags?post=21380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}