{"id":17321,"date":"2020-06-11T05:43:12","date_gmt":"2020-06-11T05:43:12","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/"},"modified":"2020-07-02T18:08:33","modified_gmt":"2020-07-02T18:08:33","slug":"que-es-el-coeficiente-de-conversion-interna-icc-definicion","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/","title":{"rendered":"\u00bfQu\u00e9 es el coeficiente de conversi\u00f3n interna? &#8211; ICC &#8211; Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">El coeficiente de conversi\u00f3n interno (ICC), \u03b1, caracteriza la competencia entre la conversi\u00f3n interna y la emisi\u00f3n de rayos gamma.\u00a0En algunos casos, se favorece la conversi\u00f3n interna sobre la desintegraci\u00f3n gamma.\u00a0Dosimetr\u00eda de radiaci\u00f3n<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<figure id=\"attachment_25106\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-25106\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger.png\"><img loading=\"lazy\" class=\"size-medium wp-image-25106 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" alt=\"Conversi\u00f3n interna - ICE m\u00e1s barrena\" width=\"280\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" \/><\/a><figcaption id=\"caption-attachment-25106\" class=\"wp-caption-text\">Conversi\u00f3n interna seguida de emisi\u00f3n de electrones Auger.<\/figcaption><\/figure>\n<p><strong>La conversi\u00f3n interna<\/strong>\u00a0es un proceso electromagn\u00e9tico, por el cual un estado excitado nuclear decae por la\u00a0<strong>emisi\u00f3n directa<\/strong>\u00a0de uno de sus\u00a0<strong>electrones at\u00f3micos<\/strong>\u00a0.\u00a0<strong>La conversi\u00f3n interna<\/strong>\u00a0compite con\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/gamma-decay-gamma-radioactivity\/\">la emisi\u00f3n gamma<\/a>\u00a0, pero en este caso los campos multipolares electromagn\u00e9ticos del\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/atomic-nucleus\/\">n\u00facleo<\/a>\u00a0no producen la emisi\u00f3n de un rayo gamma, sino que los campos interact\u00faan directamente con los electrones at\u00f3micos.<\/p>\n<h2>Coeficiente de conversi\u00f3n interna<\/h2>\n<p>El\u00a0<strong>coeficiente de conversi\u00f3n interno<\/strong>\u00a0(ICC),\u00a0<strong>\u03b1<\/strong>\u00a0, caracteriza la competencia entre la conversi\u00f3n interna y la emisi\u00f3n de rayos gamma.\u00a0En algunos casos, se favorece la conversi\u00f3n interna sobre la desintegraci\u00f3n gamma.\u00a0En otros puede ser completamente insignificante.\u00a0El\u00a0<strong>coeficiente de conversi\u00f3n interno<\/strong>\u00a0se define como la relaci\u00f3n entre el n\u00famero de decaimientos de conversi\u00f3n internos y el n\u00famero de decaimientos gamma.\u00a0Este ICC se define para cada capa de electrones (es decir, las capas K, L y M, etc.), de modo que la relaci\u00f3n total, \u03b1\u00a0<sub>total<\/sub>\u00a0, es la suma de las ICC para cada capa como:<\/p>\n<p>\u03b1\u00a0<sub>total<\/sub>\u00a0= \u03b1\u00a0<sub>K<\/sub>\u00a0+ \u03b1\u00a0<sub>L<\/sub>\u00a0+ \u03b1\u00a0<sub>M<\/sub>\u00a0= n\u00famero de IC \/ n\u00famero de desintegraciones gamma<\/p>\n<p>Por ejemplo, en la desintegraci\u00f3n del estado excitado a 35 keV de\u00a0<sup>125<\/sup>\u00a0Te (que se produce por la desintegraci\u00f3n de 125I), el 7% de las desintegraciones emiten rayos gamma, mientras que el 93% emite electrones de conversi\u00f3n.\u00a0Por lo tanto, un coeficiente de conversi\u00f3n interno de este estado excitado (\u00a0<sup>125<\/sup>\u00a0Te) es ICC = 93\/7 = 13.3.<\/p>\n<p>Usando la calculadora de coeficiente de conversi\u00f3n interna de Band-Raman, los ICC pueden calcularse utilizando principios de f\u00edsica at\u00f3mica, ya que depende principalmente de la densidad de los electrones at\u00f3micos en el centro del n\u00facleo.\u00a0Para aumentar el n\u00famero at\u00f3mico (Z) y disminuir la energ\u00eda de los rayos gamma, se observa que los coeficientes de conversi\u00f3n internos aumentan.<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>El coeficiente de conversi\u00f3n interno (ICC), \u03b1, caracteriza la competencia entre la conversi\u00f3n interna y la emisi\u00f3n de rayos gamma.\u00a0En algunos casos, se favorece la conversi\u00f3n interna sobre la desintegraci\u00f3n gamma.\u00a0Dosimetr\u00eda de radiaci\u00f3n Conversi\u00f3n interna seguida de emisi\u00f3n de electrones Auger. La conversi\u00f3n interna\u00a0es un proceso electromagn\u00e9tico, por el cual un estado excitado nuclear decae &#8230; <a title=\"\u00bfQu\u00e9 es el coeficiente de conversi\u00f3n interna? &#8211; ICC &#8211; Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es el coeficiente de conversi\u00f3n interna? &#8211; ICC &#8211; Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[50],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es el coeficiente de conversi\u00f3n interna? - ICC - Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"El coeficiente de conversi\u00f3n interno (ICC), \u03b1, caracteriza la competencia entre la conversi\u00f3n interna y la emisi\u00f3n de rayos gamma. En algunos casos, se favorece la conversi\u00f3n interna sobre la desintegraci\u00f3n gamma. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es el coeficiente de conversi\u00f3n interna? - ICC - Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"El coeficiente de conversi\u00f3n interno (ICC), \u03b1, caracteriza la competencia entre la conversi\u00f3n interna y la emisi\u00f3n de rayos gamma. En algunos casos, se favorece la conversi\u00f3n interna sobre la desintegraci\u00f3n gamma. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-11T05:43:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-02T18:08:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger-280x300.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"2 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Internal-Conversion-ICE-plus-Auger.png\",\"width\":746,\"height\":799,\"caption\":\"Conversion interne suivie d'une \\u00e9mission d'\\u00e9lectrons Auger.\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 es el coeficiente de conversi\\u00f3n interna? - ICC - Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/#primaryimage\"},\"datePublished\":\"2020-06-11T05:43:12+00:00\",\"dateModified\":\"2020-07-02T18:08:33+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"El coeficiente de conversi\\u00f3n interno (ICC), \\u03b1, caracteriza la competencia entre la conversi\\u00f3n interna y la emisi\\u00f3n de rayos gamma. En algunos casos, se favorece la conversi\\u00f3n interna sobre la desintegraci\\u00f3n gamma. Dosimetr\\u00eda de radiaci\\u00f3n\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-coeficiente-de-conversion-interna-icc-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17321"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/comments?post=17321"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17321\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/media?parent=17321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/categories?post=17321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/tags?post=17321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}