{"id":17287,"date":"2020-06-10T20:10:53","date_gmt":"2020-06-10T20:10:53","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/"},"modified":"2020-07-02T14:19:09","modified_gmt":"2020-07-02T14:19:09","slug":"que-es-rad-dosis-absorbida-por-radiacion-definicion","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/","title":{"rendered":"\u00bfQu\u00e9 es RAD? &#8211; Dosis absorbida por radiaci\u00f3n &#8211; Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">El rad (una abreviatura de Dosis Absorbida por Radiaci\u00f3n) es la unidad no SI de la dosis absorbida.\u00a0Una dosis de un rad es equivalente a la deposici\u00f3n de cien ergios de energ\u00eda en un gramo de cualquier material.\u00a0Dosimetr\u00eda de radiaci\u00f3n<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p><strong>La dosis absorbida<\/strong>\u00a0se define como la cantidad de energ\u00eda depositada por la radiaci\u00f3n ionizante en una sustancia.\u00a0<strong>La dosis absorbida<\/strong>\u00a0se da el s\u00edmbolo\u00a0<strong>D<\/strong>\u00a0.\u00a0El\u00a0<strong>rad<\/strong>\u00a0(una abreviatura de\u00a0<strong>R<\/strong>\u00a0adiation\u00a0<strong>A<\/strong>\u00a0bsorbed\u00a0<strong>D<\/strong>\u00a0ose) es la\u00a0<strong>unidad no SI<\/strong>\u00a0de la dosis absorbida.\u00a0La dosis absorbida tambi\u00e9n se mide en una unidad llamada gray (Gy), que se deriva del sistema SI.\u00a0La unidad no SI\u00a0<strong>rad<\/strong>\u00a0se utiliza predominantemente en el EE.UU..<\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-definition.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25307 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-definition.png\" alt=\"dosis absorbida - definici\u00f3n\" width=\"180\" height=\"72\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-definition.png\" \/><\/a><\/p>\n<p>Unidades de dosis absorbida:<\/p>\n<ul>\n<li>Gris.\u00a0Una dosis de un gray es equivalente a una unidad de energ\u00eda (julio) depositada en un kilogramo de una sustancia.<\/li>\n<li>RAD.\u00a0Una dosis de un rad es equivalente a la deposici\u00f3n de cien ergios de energ\u00eda en un gramo de cualquier material.<\/li>\n<\/ul>\n<h2>RAD &#8211; Unidad de dosis absorbida<\/h2>\n<p>Una dosis de\u00a0<strong>un rad<\/strong>\u00a0es equivalente a la deposici\u00f3n de\u00a0<strong>cien ergios<\/strong>\u00a0de energ\u00eda en\u00a0<strong>un gramo<\/strong>\u00a0de cualquier material.\u00a0Tenga en cuenta que, el erg es una unidad de energ\u00eda y trabajo igual a 10\u00a0<sup>\u22127<\/sup>\u00a0julios.\u00a0Una unidad relacionada, el roentgen, se utiliza para cuantificar la exposici\u00f3n a la radiaci\u00f3n.\u00a0El factor F se puede usar para convertir entre rads y roentgens.<\/p>\n<p>Un rad es una dosis significativamente menor que un gris, que es una gran cantidad de dosis absorbida.\u00a0Una persona que ha absorbido una dosis de 100 rad en todo el cuerpo ha absorbido un julio de energ\u00eda en cada kg de tejido corporal (es decir, 1 Gy).\u00a0Las dosis absorbidas medidas en la industria (excepto la medicina nuclear) a menudo tienen dosis comparables a un rad y a menudo se usan los siguientes m\u00faltiplos:<\/p>\n<p><strong>1 mrad (milirad) = 1E-3 rad<\/strong><\/p>\n<p><strong>1 krad (kilorad) = 1E3 rad<\/strong><\/p>\n<p>Las conversiones de las unidades SI a otras unidades son las siguientes:<\/p>\n<ul>\n<li>1 Gy = 100 rad<\/li>\n<li>1 mGy = 100 mrad<\/li>\n<\/ul>\n<p>El gray y el rad son unidades f\u00edsicas.\u00a0Describen el efecto f\u00edsico de la radiaci\u00f3n incidente (es decir, la cantidad de energ\u00eda depositada por kg), pero no nos dice nada sobre las consecuencias biol\u00f3gicas de dicha deposici\u00f3n de energ\u00eda en el tejido vivo.<\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Ejemplos de dosis absorbidas en rads<\/span><\/h2>\n<p><span>Debemos tener en cuenta que la radiaci\u00f3n nos rodea.\u00a0En, alrededor y sobre el mundo en que vivimos. Es una fuerza de energ\u00eda natural que nos rodea.\u00a0Es una parte de nuestro mundo natural que ha estado aqu\u00ed desde el nacimiento de nuestro planeta.\u00a0En los siguientes puntos tratamos de expresar enormes rangos de exposici\u00f3n a la radiaci\u00f3n, que pueden obtenerse de varias fuentes.<\/span><\/p>\n<ul>\n<li><strong><span>0.005 mrad<\/span><\/strong><span>\u00a0&#8211; Dormir al lado de alguien<\/span><\/li>\n<li><strong><span>0.009 mrad<\/span><\/strong><span>\u00a0: viviendo a 30 millas de una planta de energ\u00eda nuclear durante un a\u00f1o<\/span><\/li>\n<li><strong><span>0.01 mrad<\/span><\/strong><span>\u00a0&#8211; Comer una banana<\/span><\/li>\n<li><strong><span>0.03 mrad<\/span><\/strong><span>\u00a0&#8211; Vivir dentro de 50 millas de una planta de energ\u00eda de carb\u00f3n durante un a\u00f1o<\/span><\/li>\n<li><strong><span>1 mrad<\/span><\/strong><span>\u00a0: dosis diaria promedio recibida del fondo natural<\/span><\/li>\n<li><strong><span>2 mrad<\/span><\/strong><span>\u00a0&#8211; radiograf\u00eda de t\u00f3rax<\/span><\/li>\n<li><strong><span>4 mrad<\/span><\/strong><span>\u00a0: un vuelo en avi\u00f3n de 5 horas<\/span><\/li>\n<li><strong><span>60 mrad<\/span><\/strong><span>\u00a0&#8211; mamograf\u00eda<\/span><\/li>\n<li><strong><span>100 mrad<\/span><\/strong><span>\u00a0&#8211; L\u00edmite de dosis para miembros individuales del p\u00fablico, dosis efectiva total por a\u00f1o<\/span><\/li>\n<li><strong><span>365 mrad<\/span><\/strong><span>\u00a0: dosis media anual recibida del fondo natural<\/span><\/li>\n<li><strong><span>580 mrad<\/span><\/strong><span>\u00a0: tomograf\u00eda computarizada del t\u00f3rax<\/span><\/li>\n<li><strong><span>1000 mrad<\/span><\/strong><span>\u00a0: dosis media anual recibida de un entorno natural en Ramsar, Ir\u00e1n<\/span><\/li>\n<li><strong><span>2 000 mrad<\/span><\/strong><span>\u00a0: tomograf\u00eda computarizada de cuerpo completo<\/span><\/li>\n<li><strong><span>17 500 mrad<\/span><\/strong><span>\u00a0: dosis anual de radiaci\u00f3n natural en una playa de monazita cerca de Guarapari, Brasil.<\/span><\/li>\n<li><strong><span>500 000 mrad<\/span><\/strong><span>\u00a0: dosis necesaria para matar a un humano con un riesgo del 50% en 30 d\u00edas (LD50 \/ 30), si la dosis se recibe durante un\u00a0<\/span><strong><span>per\u00edodo muy corto<\/span><\/strong><span>\u00a0.<\/span><\/li>\n<\/ul>\n<p><span>Como se puede ver, las dosis bajas son comunes en la vida cotidiana.\u00a0Los ejemplos anteriores pueden ayudar a ilustrar las magnitudes relativas.\u00a0Desde el punto de vista de las consecuencias biol\u00f3gicas, es muy importante distinguir entre las dosis recibidas durante\u00a0<strong>per\u00edodos\u00a0<\/strong><\/span><strong><span>cortos<\/span><\/strong><span>\u00a0y\u00a0<\/span><strong><span>prolongados<\/span><\/strong><span>\u00a0.\u00a0Una \u00bb\u00a0<\/span><strong><span>dosis aguda<\/span><\/strong><span>\u00a0\u00bb es aquella que ocurre durante un per\u00edodo de tiempo corto y finito, mientras que una \u00bb\u00a0<\/span><strong><span>dosis cr\u00f3nica<\/span><\/strong><span>\u00abEs una dosis que contin\u00faa durante un per\u00edodo prolongado de tiempo para que se describa mejor mediante una tasa de dosis.\u00a0Las dosis altas tienden a matar c\u00e9lulas, mientras que las dosis bajas tienden a da\u00f1arlas o cambiarlas.\u00a0Las dosis bajas distribuidas durante largos per\u00edodos de tiempo no causan un problema inmediato a ning\u00fan \u00f3rgano del cuerpo.\u00a0Los efectos de bajas dosis de radiaci\u00f3n ocurren a nivel celular y los resultados pueden no observarse durante muchos a\u00f1os.<\/span><\/p>\n<h2><span>C\u00e1lculo de la tasa de dosis protegida en rads<\/span><\/h2>\n<p><span>Suponga la\u00a0<\/span><strong><span>fuente isotr\u00f3pica puntual<\/span><\/strong><span>\u00a0que contiene\u00a0<\/span><strong><span>1.0 Ci de\u00a0<\/span><sup><span>137<\/span><\/sup><span>\u00a0Cs<\/span><\/strong><span>\u00a0, que tiene una\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/radioactive-decay-law\/half-life\/\"><span>vida media<\/span><\/a><span>\u00a0de\u00a0<\/span><strong><span>30.2 a\u00f1os<\/span><\/strong><span>\u00a0.\u00a0Tenga en cuenta que la relaci\u00f3n entre la vida media y la cantidad de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/radionuclide-radioisotope\/\"><span>radion\u00faclido<\/span><\/a><span>\u00a0requerida para dar una actividad de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/units-of-radioactivity\/curie-unit-of-radioactivity\/\"><span>un curie<\/span><\/a><span>\u00a0se muestra a continuaci\u00f3n.\u00a0Esta cantidad de material se puede calcular usando \u03bb, que es la\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/radioactive-decay-law\/decay-constant\/\"><span>constante<\/span><\/a><span>\u00a0de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/radioactive-decay-law\/decay-constant\/\">descomposici\u00f3n<\/a>\u00a0de ciertos nucleidos:<\/span><\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Curie-Unit-of-Activity.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-24886 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Curie-Unit-of-Activity.png\" alt=\"Curie - Unidad de Actividad\" width=\"378\" height=\"61\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Curie-Unit-of-Activity.png\" \/><\/a><\/p>\n<p><span>Alrededor del 94,6 por ciento se desintegra por\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radioactive-decay\/beta-decay-beta-radioactivity\/\"><span>emisi\u00f3n beta<\/span><\/a><span>\u00a0a un\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/atom-properties-of-atoms\/nuclides\/isomers\/\"><span>is\u00f3mero nuclear<\/span><\/a><span>\u00a0de bario\u00a0metaestable\u00a0: bario-137m.\u00a0El pico principal de fotones de Ba-137m es\u00a0<\/span><strong><span>662 keV<\/span><\/strong><span>\u00a0.\u00a0Para este c\u00e1lculo, suponga que todas las desintegraciones pasan por este canal.<\/span><\/p>\n<p><strong><span>Calcule la tasa de dosis de fotones primarios<\/span><\/strong><span>\u00a0, en rads por hora (rad.h\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0), en la superficie externa de un blindaje de plomo de 5 cm de espesor.\u00a0La tasa de dosis de fotones primarios descuida todas las part\u00edculas secundarias.\u00a0Suponga que la distancia efectiva de la fuente desde el punto de dosis es de\u00a0<\/span><strong><span>10 cm<\/span><\/strong><span>\u00a0.\u00a0Tambi\u00e9n supondremos que el punto de dosis es tejido blando y que puede ser simulado razonablemente por el agua y usamos el coeficiente de absorci\u00f3n de energ\u00eda de masa para el agua.<\/span><\/p>\n<p><span>Ver tambi\u00e9n:\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/interaction-radiation-matter\/interaction-gamma-radiation-matter\/gamma-ray-attenuation\/\"><span>atenuaci\u00f3n de rayos gamma<\/span><\/a><\/p>\n<p><span>Ver tambi\u00e9n:\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/atomic-nuclear-physics\/radiation\/shielding-of-ionizing-radiation\/shielding-gamma-radiation\/\"><span>Blindaje de rayos gamma<\/span><\/a><\/p>\n<p><strong><span>Soluci\u00f3n:<\/span><\/strong><\/p>\n<p><span>La tasa de dosis de fotones primarios se\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/interaction-radiation-matter\/interaction-gamma-radiation-matter\/gamma-ray-attenuation\/\"><span>aten\u00faa exponencialmente<\/span><\/a><span>\u00a0, y la tasa de dosis de fotones primarios, teniendo en cuenta el escudo, viene dada por:<\/span><\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-rate-calculation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25304 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-rate-calculation.png\" alt=\"c\u00e1lculo de la tasa de dosis\" width=\"671\" height=\"307\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/dose-rate-calculation.png\" \/><\/a><\/p>\n<p><span>Como se puede ver, no tenemos en cuenta la acumulaci\u00f3n de radiaci\u00f3n secundaria.\u00a0Si se producen part\u00edculas secundarias o si la radiaci\u00f3n primaria cambia su energ\u00eda o direcci\u00f3n, entonces la atenuaci\u00f3n efectiva ser\u00e1 mucho menor.\u00a0Esta suposici\u00f3n generalmente subestima la tasa de dosis real, especialmente para protecciones gruesas y cuando el punto de dosis est\u00e1 cerca de la superficie de la protecci\u00f3n, pero esta suposici\u00f3n simplifica todos los c\u00e1lculos.\u00a0Para este caso, la tasa de dosis real (con la acumulaci\u00f3n de radiaci\u00f3n secundaria) ser\u00e1 m\u00e1s de dos veces mayor.<\/span><\/p>\n<p><span>Para calcular la\u00a0<\/span><strong><span>tasa de dosis absorbida<\/span><\/strong><span>\u00a0, tenemos que usar en la f\u00f3rmula:<\/span><\/p>\n<ul>\n<li><span>k = 5,76 x 10\u00a0<\/span><sup><span>-7<\/span><\/sup><\/li>\n<li><span>S = 3.7 x 10\u00a0<\/span><sup><span>10<\/span><\/sup><span>\u00a0s\u00a0<\/span><sup><span>-1<\/span><\/sup><\/li>\n<li><span>E = 0.662 MeV<\/span><\/li>\n<li><span>\u03bc\u00a0<\/span><sub><span>t<\/span><\/sub><span>\u00a0\/ \u03c1 = 0.0326 cm\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0\/ g (los valores est\u00e1n disponibles en NIST)<\/span><\/li>\n<li><span>\u03bc = 1.289 cm\u00a0<\/span><sup><span>-1<\/span><\/sup><span>\u00a0(los valores est\u00e1n disponibles en NIST)<\/span><\/li>\n<li><span>D = 5 cm<\/span><\/li>\n<li><span>r = 10 cm<\/span><\/li>\n<\/ul>\n<p><strong><span>Resultado:<\/span><\/strong><\/p>\n<p><span>La tasa de dosis absorbida resultante en grises por hora es entonces:<\/span><\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-rad-calculation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25305 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-rad-calculation.png\" alt=\"tasa de dosis absorbida - rad - c\u00e1lculo\" width=\"563\" height=\"166\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-rad-calculation.png\" \/><\/a><\/p>\n<p><span>Si queremos dar cuenta de la acumulaci\u00f3n de radiaci\u00f3n secundaria, entonces tenemos que incluir el factor de acumulaci\u00f3n.\u00a0La\u00a0<\/span><strong><span>f\u00f3rmula extendida<\/span><\/strong><span>\u00a0para la tasa de dosis es entonces:<\/span><\/p>\n<p><a href=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-gray-calculation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-25303 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-gray-calculation.png\" alt=\"tasa de dosis absorbida - gris\" width=\"693\" height=\"158\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-rate-gray-calculation.png\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El rad (una abreviatura de Dosis Absorbida por Radiaci\u00f3n) es la unidad no SI de la dosis absorbida.\u00a0Una dosis de un rad es equivalente a la deposici\u00f3n de cien ergios de energ\u00eda en un gramo de cualquier material.\u00a0Dosimetr\u00eda de radiaci\u00f3n La dosis absorbida\u00a0se define como la cantidad de energ\u00eda depositada por la radiaci\u00f3n ionizante en &#8230; <a title=\"\u00bfQu\u00e9 es RAD? &#8211; Dosis absorbida por radiaci\u00f3n &#8211; Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es RAD? &#8211; Dosis absorbida por radiaci\u00f3n &#8211; Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[50],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es RAD? - Dosis absorbida por radiaci\u00f3n - Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"El rad (una abreviatura de Dosis Absorbida por Radiaci\u00f3n) es la unidad no SI de la dosis absorbida. Una dosis de un rad es equivalente a la deposici\u00f3n de cien ergios de energ\u00eda en un gramo de cualquier material. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es RAD? - Dosis absorbida por radiaci\u00f3n - Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"El rad (una abreviatura de Dosis Absorbida por Radiaci\u00f3n) es la unidad no SI de la dosis absorbida. Una dosis de un rad es equivalente a la deposici\u00f3n de cien ergios de energ\u00eda en un gramo de cualquier material. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-10T20:10:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-02T14:19:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-definition.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"5 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/absorbed-dose-definition.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 es RAD? - Dosis absorbida por radiaci\\u00f3n - Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/#primaryimage\"},\"datePublished\":\"2020-06-10T20:10:53+00:00\",\"dateModified\":\"2020-07-02T14:19:09+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"El rad (una abreviatura de Dosis Absorbida por Radiaci\\u00f3n) es la unidad no SI de la dosis absorbida. Una dosis de un rad es equivalente a la deposici\\u00f3n de cien ergios de energ\\u00eda en un gramo de cualquier material. Dosimetr\\u00eda de radiaci\\u00f3n\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-rad-dosis-absorbida-por-radiacion-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17287"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/comments?post=17287"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17287\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/media?parent=17287"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/categories?post=17287"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/tags?post=17287"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}