{"id":17049,"date":"2020-03-14T02:02:42","date_gmt":"2020-03-14T02:02:42","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/que-es-el-equivalente-de-dosis-profunda\/"},"modified":"2020-07-02T12:54:49","modified_gmt":"2020-07-02T12:54:49","slug":"que-es-el-equivalente-de-dosis-profunda","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/","title":{"rendered":"\u00bfQu\u00e9 es el equivalente de dosis profunda?"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Equivalente a dosis profunda: equivalente a dosis poco profunda.\u00a0Hp (0.07) tambi\u00e9n se llama la dosis baja equivalente.\u00a0Para la evaluaci\u00f3n de los \u00f3rganos profundos y el control de la dosis efectiva, se elige Hp (10) con una profundidad d = 10 mm.\u00a0Hp (10) tambi\u00e9n se llama el equivalente de dosis profunda.\u00a0Dosimetr\u00eda de radiaci\u00f3n<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p>En general, el ICRP define cantidades operativas para el\u00a0<strong>\u00e1rea<\/strong>\u00a0y el\u00a0<strong>monitoreo individual<\/strong>\u00a0de exposiciones externas.\u00a0Las cantidades operativas para el\u00a0<strong>monitoreo del \u00e1rea<\/strong>\u00a0son:<\/p>\n<ul>\n<li><strong>Dosis ambiental equivalente<\/strong>\u00a0, H * (10).\u00a0La dosis equivalente ambiental es una cantidad operativa para el monitoreo del \u00e1rea de radiaci\u00f3n fuertemente penetrante.<\/li>\n<li><strong>Dosis direccional equivalente<\/strong>\u00a0, H &#8216;(d, \u03a9).\u00a0La dosis direccional equivalente es una cantidad operativa para el monitoreo del \u00e1rea de radiaci\u00f3n d\u00e9bilmente penetrante.<\/li>\n<\/ul>\n<p>Las cantidades operativas para el\u00a0<strong>monitoreo individual<\/strong>\u00a0son:<\/p>\n<ul>\n<li><strong>Dosis personal equivalente<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(0.07)<\/strong>\u00a0.\u00a0La\u00a0dosis equivalente de\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(0.07)<\/strong>\u00a0es una cantidad operativa para el monitoreo individual para la evaluaci\u00f3n de la dosis para la piel y las manos y los pies.<\/li>\n<li><strong>Dosis personal equivalente<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(10)<\/strong>\u00a0.\u00a0La\u00a0dosis equivalente de\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(10)<\/strong>\u00a0es una cantidad operativa para el monitoreo individual para la evaluaci\u00f3n de la dosis efectiva.<\/li>\n<\/ul>\n<p>Referencia especial: CIPR, 2007. Recomendaciones de 2007 de la Comisi\u00f3n Internacional de Protecci\u00f3n Radiol\u00f3gica.\u00a0Publicaci\u00f3n 103 de la CIPR. Ann.\u00a0ICRP 37 (2-4).<\/p>\n<h2>Dosis profunda equivalente y dosis baja equivalente<\/h2>\n<h3>Dosis personal equivalente &#8211; H\u00a0<sub>p<\/sub>\u00a0(10) &#8211; H\u00a0<sub>p<\/sub>\u00a0(0.07)<\/h3>\n<p>Generalmente, la\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/personal-dose-equivalent\/\"><strong>dosis personal equivalente<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><\/a><strong>\u00a0(d),<\/strong>\u00a0es una cantidad operativa para el monitoreo individual.\u00a0Seg\u00fan la ICRP, la dosis equivalente personal se define como:<\/p>\n<p>Publicaci\u00f3n 103 de la CIPR:<\/p>\n<p><em>\u00abLa dosis equivalente en los tejidos blandos (com\u00fanmente interpretada como la &#8216;esfera ICRU&#8217;) a una profundidad apropiada, d, debajo de un punto espec\u00edfico en el cuerpo humano.\u00a0\u00ab<\/em><\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p><span>La dosis equivalente personal recibe el s\u00edmbolo\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(d).\u00a0<\/span><\/strong><span>Dos cantidades operativas comunes para el monitoreo individual definido por el ICRP son:<\/span><\/p>\n<ul>\n<li><strong><span>Dosis personal equivalente<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(0.07)<\/span><\/strong><span>\u00a0.\u00a0La\u00a0dosis equivalente de\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(0.07)<\/span><\/strong><span>\u00a0es una cantidad operativa para el monitoreo individual para la evaluaci\u00f3n de la dosis para la piel y las manos y los pies.<\/span><\/li>\n<li><strong><span>Dosis personal equivalente<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0.\u00a0La\u00a0dosis equivalente de\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0es una cantidad operativa para el monitoreo individual para la evaluaci\u00f3n de la dosis efectiva.<\/span><\/li>\n<\/ul>\n<p><span>Como se puede ver, se pueden usar varias profundidades.\u00a0La\u00a0<\/span><strong><span>dosis personal equivalente<\/span><\/strong><span>\u00a0, H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(d), se puede evaluar indirectamente con un detector delgado equivalente de tejido (\u00a0<\/span><a href=\"http:\/\/radiation-dosimetry.org\/\"><span>dos\u00edmetro de radiaci\u00f3n<\/span><\/a><span>\u00a0) que se usa en la superficie del cuerpo y se cubre con un grosor apropiado de material equivalente de tejido.\u00a0El punto especificado, d, normalmente se considera donde se usa el dos\u00edmetro de radiaci\u00f3n.<\/span><\/p>\n<p><span>Para la evaluaci\u00f3n de los \u00f3rganos superficiales y el control de la dosis equivalente, se emplean profundidades de 0,07 mm para la piel y 3 mm para el cristalino del ojo, y los equivalentes de dosis personales para esas profundidades se indican con H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(0,07) y H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0( 3), respectivamente.\u00a0H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(0.07) tambi\u00e9n se llama la\u00a0<\/span><strong><span>dosis equivalente baja<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>Para la evaluaci\u00f3n de los \u00f3rganos profundos y el\u00a0<\/span><strong><span>control de la dosis efectiva<\/span><\/strong><span>\u00a0,\u00a0se elige\u00a0<\/span><strong><span>H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(10)<\/span><\/strong><span>\u00a0con una profundidad d = 10 mm.\u00a0H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(10) tambi\u00e9n se llama la\u00a0<\/span><strong><span>dosis profunda equivalente<\/span><\/strong><span>\u00a0.\u00a0Si el dos\u00edmetro personal se usa en una posici\u00f3n del cuerpo representativa de su exposici\u00f3n, a dosis bajas y bajo el supuesto de una exposici\u00f3n uniforme de todo el cuerpo, el valor de Hp (10) proporciona un valor de dosis efectivo suficientemente preciso para fines de protecci\u00f3n radiol\u00f3gica .\u00a0Las radiaciones de neutrones y gamma contribuyen tanto a la dosis profunda como a la superficial, pero la radiaci\u00f3n beta se absorbe completamente en la piel y, por lo tanto, solo contribuye a la dosis superficial.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min.png\"><img loading=\"lazy\" class=\"aligncenter size-large wp-image-25493 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" alt=\"Medici\u00f3n y monitoreo de radiaci\u00f3n - Cantidades y l\u00edmites\" width=\"1024\" height=\"600\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Equivalente a dosis profunda: equivalente a dosis poco profunda.\u00a0Hp (0.07) tambi\u00e9n se llama la dosis baja equivalente.\u00a0Para la evaluaci\u00f3n de los \u00f3rganos profundos y el control de la dosis efectiva, se elige Hp (10) con una profundidad d = 10 mm.\u00a0Hp (10) tambi\u00e9n se llama el equivalente de dosis profunda.\u00a0Dosimetr\u00eda de radiaci\u00f3n En general, el &#8230; <a title=\"\u00bfQu\u00e9 es el equivalente de dosis profunda?\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es el equivalente de dosis profunda?\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[50],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es el equivalente de dosis profunda?<\/title>\n<meta name=\"description\" content=\"Equivalente a dosis profunda: equivalente a dosis poco profunda. Hp (0.07) tambi\u00e9n se llama la dosis baja equivalente. Para la evaluaci\u00f3n de los \u00f3rganos profundos y el control de la dosis efectiva, se elige Hp (10) con una profundidad d = 10 mm. Hp (10) tambi\u00e9n se llama el equivalente de dosis profunda. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es el equivalente de dosis profunda?\" \/>\n<meta property=\"og:description\" content=\"Equivalente a dosis profunda: equivalente a dosis poco profunda. Hp (0.07) tambi\u00e9n se llama la dosis baja equivalente. Para la evaluaci\u00f3n de los \u00f3rganos profundos y el control de la dosis efectiva, se elige Hp (10) con una profundidad d = 10 mm. Hp (10) tambi\u00e9n se llama el equivalente de dosis profunda. Dosimetr\u00eda de radiaci\u00f3n\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-14T02:02:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-02T12:54:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"3 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min.png\",\"width\":1141,\"height\":668,\"caption\":\"Strahlungsmessung und -\\u00fcberwachung - Mengen und Grenzen\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/\",\"name\":\"\\u00bfQu\\u00e9 es el equivalente de dosis profunda?\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/#primaryimage\"},\"datePublished\":\"2020-03-14T02:02:42+00:00\",\"dateModified\":\"2020-07-02T12:54:49+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Equivalente a dosis profunda: equivalente a dosis poco profunda. Hp (0.07) tambi\\u00e9n se llama la dosis baja equivalente. Para la evaluaci\\u00f3n de los \\u00f3rganos profundos y el control de la dosis efectiva, se elige Hp (10) con una profundidad d = 10 mm. Hp (10) tambi\\u00e9n se llama el equivalente de dosis profunda. Dosimetr\\u00eda de radiaci\\u00f3n\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-el-equivalente-de-dosis-profunda\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17049"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/comments?post=17049"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/17049\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/media?parent=17049"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/categories?post=17049"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/tags?post=17049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}