{"id":16650,"date":"2020-03-09T14:11:58","date_gmt":"2020-03-09T14:11:58","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/"},"modified":"2020-06-30T11:10:43","modified_gmt":"2020-06-30T11:10:43","slug":"que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/","title":{"rendered":"Qu\u00e9 es parte de los detectores HPGe &#8211; Soporte &#8211; Dedo fr\u00edo &#8211; Definici\u00f3n"},"content":{"rendered":"<figure id=\"attachment_26112\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26112\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium.png\"><img loading=\"lazy\" class=\"size-medium wp-image-26112 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2020\/12\/el-detector-de-germanio-de-alta-pureza-300x204.png\" alt=\"Detector HPGe - Germanio\" width=\"300\" height=\"204\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2020\/12\/el-detector-de-germanio-de-alta-pureza-300x204.png\" \/><\/a><figcaption id=\"caption-attachment-26112\" class=\"wp-caption-text\"><span>Detector HPGe con criostato LN2 Fuente: canberra.com<\/span><\/figcaption><\/figure>\n<p><span>El principal inconveniente de los detectores de germanio es que deben enfriarse a temperaturas de nitr\u00f3geno l\u00edquido.\u00a0Debido a que el germanio tiene un\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/band-gap-energy-gap\/\"><span>intervalo de banda<\/span><\/a><span>\u00a0relativamente bajo\u00a0, estos detectores deben enfriarse para reducir la generaci\u00f3n t\u00e9rmica de\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\"><span>portadores<\/span><\/a><span>\u00a0de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/majority-and-minority-carriers-in-semiconductors\/\">carga<\/a>\u00a0a un nivel aceptable.\u00a0De lo contrario, el ruido inducido por la corriente de fuga destruye la resoluci\u00f3n energ\u00e9tica del detector.\u00a0Recuerde, la brecha de banda (una distancia entre la\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/conduction-and-valence-band-in-semiconductors\/\"><span>valencia y la banda de conducci\u00f3n<\/span><\/a><span>\u00a0) es muy baja para germanio (Egap = 0.67 eV).\u00a0El enfriamiento a la temperatura del nitr\u00f3geno l\u00edquido (-195.8 \u00b0 C; -320 \u00b0 F) reduce las excitaciones t\u00e9rmicas de los electrones de valencia, de modo que solo una interacci\u00f3n de rayos gamma puede dar a un electr\u00f3n la energ\u00eda necesaria para cruzar la brecha de banda y alcanzar la banda de conducci\u00f3n.<\/span><\/p>\n<p><span>Por lo tanto, los\u00a0<\/span><strong><span>detectores HPGe<\/span><\/strong><span>\u00a0generalmente est\u00e1n equipados con un\u00a0<\/span><strong><span>criostato<\/span><\/strong><span>\u00a0.\u00a0Los cristales de germanio se mantienen dentro de un recipiente de metal evacuado denominado\u00a0<\/span><strong><span>soporte del detector<\/span><\/strong><span>\u00a0.\u00a0El soporte del detector, as\u00ed como la \u00abtapa final\u00bb, son delgados para evitar la atenuaci\u00f3n de los fotones de baja energ\u00eda.\u00a0El soporte generalmente est\u00e1 hecho de aluminio y t\u00edpicamente tiene un grosor de 1 mm.\u00a0La tapa final, tambi\u00e9n est\u00e1 generalmente hecha de aluminio.\u00a0El cristal HPGe dentro del soporte est\u00e1 en contacto t\u00e9rmico con una varilla de metal llamada\u00a0<\/span><strong><span>dedo fr\u00edo<\/span><\/strong><span>\u00a0.\u00a0El dedo fr\u00edo transfiere calor desde el conjunto del detector al\u00a0dep\u00f3sito de\u00a0nitr\u00f3geno l\u00edquido (LN\u00a0<\/span><sub><span>2<\/span><\/sub><span>\u00a0).\u00a0La combinaci\u00f3n del recipiente de metal al vac\u00edo, el\u00a0<\/span><strong><span>dedo fr\u00edo<\/span><\/strong><span>\u00a0y el\u00a0<\/span><strong><span>matraz Dewar<\/span><\/strong><span>para el nitr\u00f3geno l\u00edquido el cri\u00f3geno se llama\u00a0<\/span><strong><span>criostato<\/span><\/strong><span>.\u00a0El preamplificador detector de germanio normalmente se incluye como parte del paquete de criostato.\u00a0Dado que el preamplificador debe ubicarse lo m\u00e1s cerca posible para que se pueda minimizar la capacitancia general, el preamplificador se instala conjuntamente.\u00a0Las etapas de entrada del preamplificador tambi\u00e9n se enfr\u00edan.\u00a0El dedo fr\u00edo se extiende m\u00e1s all\u00e1 del l\u00edmite de vac\u00edo del criostato en un matraz Dewar que est\u00e1 lleno de nitr\u00f3geno l\u00edquido.\u00a0La inmersi\u00f3n del dedo fr\u00edo en el nitr\u00f3geno l\u00edquido mantiene el cristal HPGe a una temperatura baja constante.\u00a0La temperatura del nitr\u00f3geno l\u00edquido se mantiene constante a 77 K (-195.8 \u00b0 C; -320 \u00b0 F) por ebullici\u00f3n lenta del l\u00edquido, lo que resulta en la evoluci\u00f3n del gas nitr\u00f3geno.\u00a0Dependiendo del tama\u00f1o y el dise\u00f1o, el tiempo de retenci\u00f3n de los matraces de vac\u00edo var\u00eda de unas pocas horas a unas pocas semanas.<\/span><\/p>\n<p><span>El enfriamiento con nitr\u00f3geno l\u00edquido es inconveniente, ya que el detector requiere horas para enfriarse a la temperatura de funcionamiento antes de que pueda usarse, y no se puede permitir que se caliente durante el uso.\u00a0Los detectores HPGe pueden calentarse a temperatura ambiente\u00a0<\/span><strong><span>cuando no est\u00e1n en uso<\/span><\/strong><span>\u00a0.\u00a0Cabe se\u00f1alar que los cristales de Ge (Li) nunca podr\u00edan calentarse, ya que el litio saldr\u00eda del cristal y arruinar\u00eda el detector.<\/span><\/p>\n<p><span>Se hicieron disponibles sistemas comerciales que utilizan\u00a0<\/span><strong><span>t\u00e9cnicas avanzadas de refrigeraci\u00f3n<\/span><\/strong><span>\u00a0(por ejemplo, un\u00a0\u00a0<\/span><strong><span>enfriador de tubo de pulso<\/span><\/strong><span>\u00a0) para eliminar la necesidad de enfriamiento con nitr\u00f3geno l\u00edquido.\u00a0Este sistema de enfriamiento es un criostato alimentado el\u00e9ctricamente,\u00a0<\/span><strong><span>completamente\u00a0libre de\u00a0LN\u00a0<\/span><sub><span>2<\/span><\/sub><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>Ver tambi\u00e9n: detectores de germanio, MIRION Technologies.\u00a0&lt;disponible en: https:\/\/www.mirion.com\/products\/germanium-detectors&gt;.<\/span><\/p>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Detector HPGe con criostato LN2 Fuente: canberra.com El principal inconveniente de los detectores de germanio es que deben enfriarse a temperaturas de nitr\u00f3geno l\u00edquido.\u00a0Debido a que el germanio tiene un\u00a0intervalo de banda\u00a0relativamente bajo\u00a0, estos detectores deben enfriarse para reducir la generaci\u00f3n t\u00e9rmica de\u00a0portadores\u00a0de\u00a0carga\u00a0a un nivel aceptable.\u00a0De lo contrario, el ruido inducido por la corriente de &#8230; <a title=\"Qu\u00e9 es parte de los detectores HPGe &#8211; Soporte &#8211; Dedo fr\u00edo &#8211; Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/\" aria-label=\"M\u00e1s en Qu\u00e9 es parte de los detectores HPGe &#8211; Soporte &#8211; Dedo fr\u00edo &#8211; Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[50],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu\u00e9 es parte de los detectores HPGe - Soporte - Dedo fr\u00edo - Definici\u00f3n<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu\u00e9 es parte de los detectores HPGe - Soporte - Dedo fr\u00edo - Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"Detector HPGe con criostato LN2 Fuente: canberra.com El principal inconveniente de los detectores de germanio es que deben enfriarse a temperaturas de nitr\u00f3geno l\u00edquido.\u00a0Debido a que el germanio tiene un\u00a0intervalo de banda\u00a0relativamente bajo\u00a0, estos detectores deben enfriarse para reducir la generaci\u00f3n t\u00e9rmica de\u00a0portadores\u00a0de\u00a0carga\u00a0a un nivel aceptable.\u00a0De lo contrario, el ruido inducido por la corriente de ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-09T14:11:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-06-30T11:10:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2020\/12\/el-detector-de-germanio-de-alta-pureza-300x204.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"3 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/es\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2020\/12\/el-detector-de-germanio-de-alta-pureza-300x204.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/\",\"name\":\"Qu\\u00e9 es parte de los detectores HPGe - Soporte - Dedo fr\\u00edo - Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/#primaryimage\"},\"datePublished\":\"2020-03-09T14:11:58+00:00\",\"dateModified\":\"2020-06-30T11:10:43+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/es\/que-es-parte-de-los-detectores-hpge-soporte-dedo-frio-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/es\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/16650"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/comments?post=16650"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/posts\/16650\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/media?parent=16650"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/categories?post=16650"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/es\/wp-json\/wp\/v2\/tags?post=16650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}