{"id":15050,"date":"2020-01-02T20:32:05","date_gmt":"2020-01-02T20:32:05","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/was-ist-half-value-layer-definition\/"},"modified":"2021-07-06T17:48:38","modified_gmt":"2021-07-06T17:48:38","slug":"was-ist-half-value-layer-definition","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/","title":{"rendered":"Was ist die Halbwertsschicht &#8211; Definition?"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den Faktor zwei ben\u00f6tigt wird.\u00a0Strahlendosimetrie<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2>Halbwertsschicht<\/h2>\n<p>Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den\u00a0<strong>Faktor zwei ben\u00f6tigt wird<\/strong>\u00a0.\u00a0Es gibt zwei Hauptmerkmale der Halbwertsschicht:<\/p>\n<ul>\n<li>Die\u00a0<b>Halbwertsschicht<\/b>\u00a0nimmt mit zunehmender Ordnungszahl des Absorbers ab.\u00a0Zum Beispiel werden 35 m Luft ben\u00f6tigt, um die Intensit\u00e4t eines 100-keV-Gammastrahls um den Faktor zwei zu verringern, wohingegen nur 0,12 mm Blei dasselbe bewirken k\u00f6nnen.<\/li>\n<li>Die\u00a0<b>Halbwertsschicht<\/b>\u00a0aller Materialien nimmt mit der Energie der Gammastrahlen zu.\u00a0Zum Beispiel von 0,26 cm f\u00fcr Eisen bei 100 keV bis etwa 1,06 cm bei 500 keV.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/half-value-layers.png\"><img loading=\"lazy\" class=\"aligncenter size-medium wp-image-12731 lazy-loaded\" src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/extrinsic-doped-semiconductor-p-type-acceptor-300x206.png\" alt=\"Halbwertsschicht\" width=\"291\" height=\"300\" data-lazy-type=\"image\" data-src=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/extrinsic-doped-semiconductor-p-type-acceptor-300x206.png\" \/><\/a><\/p>\n<div class=\"su-spacer\"><\/div>\n<p>Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den Faktor zwei ben\u00f6tigt wird.\u00a0Mit der Halbwertsschicht ist es einfach, einfache Berechnungen durchzuf\u00fchren.<br \/>\nQuelle: www.nde-ed.org<\/p>\n<div class=\"su-spacer\"><\/div>\n<p><strong>Tabelle der Halbwertsschichten<\/strong>\u00a0(in cm) f\u00fcr verschiedene Materialien bei Gammastrahlenergien von 100, 200 und 500 keV.<\/p>\n<\/div>\n<\/div>\n<table rules=\"rows\">\n<tbody>\n<tr>\n<td>Absorber<\/td>\n<td>100 keV<\/td>\n<td>200 keV<\/td>\n<td>500 keV<\/td>\n<\/tr>\n<tr>\n<td>Air<\/td>\n<td>3555 cm<\/td>\n<td>4359 cm<\/td>\n<td>6189 cm<\/td>\n<\/tr>\n<tr>\n<td>Water<\/td>\n<td>4.15 cm<\/td>\n<td>5.1 cm<\/td>\n<td>7.15 cm<\/td>\n<\/tr>\n<tr>\n<td>Carbon<\/td>\n<td>2.07 cm<\/td>\n<td>2.53 cm<\/td>\n<td>3.54 cm<\/td>\n<\/tr>\n<tr>\n<td>Aluminium<\/td>\n<td>1.59 cm<\/td>\n<td>2.14 cm<\/td>\n<td>3.05 cm<\/td>\n<\/tr>\n<tr>\n<td>Iron<\/td>\n<td>0.26 cm<\/td>\n<td>0.64 cm<\/td>\n<td>1.06 cm<\/td>\n<\/tr>\n<tr>\n<td>Copper<\/td>\n<td>0.18 cm<\/td>\n<td>0.53 cm<\/td>\n<td>0.95 cm<\/td>\n<\/tr>\n<tr>\n<td>Lead<\/td>\n<td>\u00a00.012 cm<\/td>\n<td>\u00a00.068 cm<\/td>\n<td>\u00a00.42 cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Dieser Artikel basiert auf der maschinellen \u00dcbersetzung des englischen Originalartikels. Weitere Informationen finden Sie im Artikel auf Englisch. Sie k\u00f6nnen uns helfen. Wenn Sie die \u00dcbersetzung korrigieren m\u00f6chten, senden Sie diese bitte an: translations@nuclear-power.com oder f\u00fcllen Sie das Online-\u00dcbersetzungsformular aus. Wir bedanken uns f\u00fcr Ihre Hilfe und werden die \u00dcbersetzung so schnell wie m\u00f6glich aktualisieren. Danke.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den Faktor zwei ben\u00f6tigt wird.\u00a0Strahlendosimetrie Halbwertsschicht Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den\u00a0Faktor zwei ben\u00f6tigt wird\u00a0.\u00a0Es gibt zwei Hauptmerkmale der Halbwertsschicht: Die\u00a0Halbwertsschicht\u00a0nimmt mit zunehmender Ordnungszahl &#8230; <a title=\"Was ist die Halbwertsschicht &#8211; Definition?\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/\" aria-label=\"Mehr dazu unter Was ist die Halbwertsschicht &#8211; Definition?\">Weiterlesen<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[48],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Was ist die Halbwertsschicht - Definition?<\/title>\n<meta name=\"description\" content=\"Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den Faktor zwei ben\u00f6tigt wird. Strahlendosimetrie\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Was ist die Halbwertsschicht - Definition?\" \/>\n<meta property=\"og:description\" content=\"Die Halbwertsschicht dr\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\u00e4t der einfallenden Strahlung um den Faktor zwei ben\u00f6tigt wird. Strahlendosimetrie\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-02T20:32:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-07-06T17:48:38+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/extrinsic-doped-semiconductor-p-type-acceptor-300x206.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/#primaryimage\",\"inLanguage\":\"de\",\"url\":\"http:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/extrinsic-doped-semiconductor-p-type-acceptor-300x206.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/\",\"name\":\"Was ist die Halbwertsschicht - Definition?\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/#primaryimage\"},\"datePublished\":\"2020-01-02T20:32:05+00:00\",\"dateModified\":\"2021-07-06T17:48:38+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Die Halbwertsschicht dr\\u00fcckt die Dicke des absorbierenden Materials aus, die zur Verringerung der Intensit\\u00e4t der einfallenden Strahlung um den Faktor zwei ben\\u00f6tigt wird. Strahlendosimetrie\",\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-half-value-layer-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts\/15050"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/comments?post=15050"}],"version-history":[{"count":1,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts\/15050\/revisions"}],"predecessor-version":[{"id":23186,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts\/15050\/revisions\/23186"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/media?parent=15050"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/categories?post=15050"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/tags?post=15050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}