{"id":13956,"date":"2019-12-27T23:18:55","date_gmt":"2019-12-27T23:18:55","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/"},"modified":"2020-07-09T18:11:02","modified_gmt":"2020-07-09T18:11:02","slug":"was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition","status":"publish","type":"post","link":"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/","title":{"rendered":"Was ist Deep Dose Equivalent &#8211; Shallow Dose Equivalent &#8211; Definition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">\u00c4quivalent zu einer tiefen Dosis &#8211; \u00c4quivalent zu einer flachen Dosis.\u00a0HP (0,07) wird auch als flaches Dosis\u00e4quivalent bezeichnet.\u00a0F\u00fcr die Beurteilung tiefer Organe und die Kontrolle der wirksamen Dosis wird Hp (10) mit einer Tiefe d = 10 mm gew\u00e4hlt.\u00a0HP (10) wird auch als \u00c4quivalent f\u00fcr tiefe Dosen bezeichnet.\u00a0Strahlendosimetrie<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p>Im Allgemeinen definiert die ICRP Betriebsgr\u00f6\u00dfen f\u00fcr\u00a0<strong>Bereich<\/strong>\u00a0und\u00a0<strong>individuelle \u00dcberwachung<\/strong>\u00a0externer Belichtungen.\u00a0Die Betriebsgr\u00f6\u00dfen f\u00fcr die\u00a0<strong>Fl\u00e4chen\u00fcberwachung<\/strong>\u00a0sind:<\/p>\n<ul>\n<li><strong>\u00c4quivalent zur Umgebungsdosis<\/strong>\u00a0H * (10).\u00a0Das \u00c4quivalent zur Umgebungsdosis ist eine Betriebsgr\u00f6\u00dfe f\u00fcr die Fl\u00e4chen\u00fcberwachung von stark eindringender Strahlung.<\/li>\n<li><strong>Richtungsdosis\u00e4quivalent<\/strong>\u00a0H &#8218;(d, \u03a9).\u00a0Das Richtungsdosis\u00e4quivalent ist eine Betriebsgr\u00f6\u00dfe zur Fl\u00e4chen\u00fcberwachung schwach eindringender Strahlung.<\/li>\n<\/ul>\n<p>Die Betriebsgr\u00f6\u00dfen f\u00fcr die\u00a0<strong>Einzel\u00fcberwachung<\/strong>\u00a0sind:<\/p>\n<ul>\n<li><strong>Personendosis\u00e4quivalent<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(0,07)<\/strong>\u00a0.\u00a0Das\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(0,07)<\/strong>\u00a0-Dosis\u00e4quivalent ist eine Betriebsgr\u00f6\u00dfe f\u00fcr die Einzel\u00fcberwachung zur Beurteilung der Dosis f\u00fcr Haut, H\u00e4nde und F\u00fc\u00dfe.<\/li>\n<li><strong>Personendosis\u00e4quivalent<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(10)<\/strong>\u00a0.\u00a0Das\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><strong>\u00a0(10)<\/strong>\u00a0-Dosis\u00e4quivalent ist eine Betriebsgr\u00f6\u00dfe f\u00fcr die Einzel\u00fcberwachung zur Beurteilung der wirksamen Dosis.<\/li>\n<\/ul>\n<p>Spezielle Referenz: ICRP, 2007. Die Empfehlungen 2007 der Internationalen Strahlenschutzkommission.\u00a0ICRP Publication 103. Ann.\u00a0ICRP 37 (2-4).<\/p>\n<h2>Deep Dose Equivalent und Shallow Dose Equivalent<\/h2>\n<h3>\u00c4quivalent zur pers\u00f6nlichen Dosis &#8211; H\u00a0<sub>p<\/sub>\u00a0(10) &#8211; H\u00a0<sub>p<\/sub>\u00a0(0,07)<\/h3>\n<p>Im Allgemeinen ist die\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-protection\/protection-from-exposures\/radiation-dose-measuring-and-monitoring-operational-quantities\/personal-dose-equivalent\/\"><strong>Personendosis<\/strong>\u00a0,\u00a0<strong>H\u00a0<\/strong><strong><sub>p<\/sub><\/strong><\/a><strong>\u00a0(D),<\/strong>\u00a0ist eine Betriebsmenge f\u00fcr die\u00a0einzelnen \u00dcberwachungs.\u00a0Laut ICRP ist das \u00c4quivalent zur Personendosis wie folgt definiert:<\/p>\n<p>ICRP-Ver\u00f6ffentlichung 103:<\/p>\n<p><em>\u201eDie \u00e4quivalente Dosis in Weichgewebe (\u00fcblicherweise als\u201e ICRU-Kugel \u201cinterpretiert) in einer geeigneten Tiefe d unterhalb eines bestimmten Punkts auf dem menschlichen K\u00f6rper.\u00a0&#8222;<\/em><\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p><span>Das pers\u00f6nliche Dosis\u00e4quivalent erh\u00e4lt das Symbol\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(d).\u00a0<\/span><\/strong><span>Zwei vom ICRP festgelegte gemeinsame Betriebsgr\u00f6\u00dfen f\u00fcr die individuelle \u00dcberwachung sind:<\/span><\/p>\n<ul>\n<li><strong><span>Pers\u00f6nliches Dosis\u00e4quivalent<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><span>\u00a0.\u00a0Das\u00a0Dosis\u00e4quivalent\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(0,07)<\/span><\/strong><span>\u00a0ist eine Betriebsgr\u00f6\u00dfe f\u00fcr die individuelle \u00dcberwachung zur Beurteilung der Dosis f\u00fcr die Haut sowie f\u00fcr H\u00e4nde und F\u00fc\u00dfe.<\/span><\/li>\n<li><strong><span>Pers\u00f6nliches Dosis\u00e4quivalent<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0.\u00a0Das\u00a0<\/span><strong><span>H\u00a0<\/span><\/strong><strong><sub><span>p<\/span><\/sub><\/strong><strong><span>\u00a0(10)<\/span><\/strong><span>\u00a0-Dosis\u00e4quivalent ist eine Betriebsgr\u00f6\u00dfe f\u00fcr die individuelle \u00dcberwachung zur Beurteilung der wirksamen Dosis.<\/span><\/li>\n<\/ul>\n<p><span>Wie zu sehen ist, k\u00f6nnen verschiedene Tiefen verwendet werden.\u00a0Das\u00a0<\/span><strong><span>pers\u00f6nliche Dosis\u00e4quivalent<\/span><\/strong><span>\u00a0H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(d) kann indirekt mit einem d\u00fcnnen Gewebe\u00e4quivalentdetektor (\u00a0<\/span><a href=\"http:\/\/radiation-dosimetry.org\/\"><span>Strahlungsdosimeter<\/span><\/a><span>\u00a0)\u00a0bewertet werden\u00a0, der an der K\u00f6rperoberfl\u00e4che getragen und mit einer geeigneten Dicke von Gewebe\u00e4quivalentmaterial bedeckt wird.\u00a0Der angegebene Punkt d wird normalerweise als der Ort angesehen, an dem das Strahlungsdosimeter getragen wird.<\/span><\/p>\n<p><span>Zur Beurteilung oberfl\u00e4chlicher Organe und zur Kontrolle der \u00c4quivalentdosis werden Tiefen von 0,07 mm f\u00fcr die Haut und 3 mm f\u00fcr die Augenlinse verwendet, und die pers\u00f6nlichen Dosis\u00e4quivalente f\u00fcr diese Tiefen werden mit H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(0,07) und H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0( 3).\u00a0H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(0,07) wird auch als\u00a0<\/span><strong><span>Flachdosis\u00e4quivalent bezeichnet<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>F\u00fcr die Beurteilung tiefer Organe und die\u00a0<\/span><strong><span>Kontrolle der wirksamen Dosis<\/span><\/strong><span>\u00a0wird\u00a0<\/span><strong><span>H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(10)<\/span><\/strong><span>\u00a0mit einer Tiefe d = 10 mm gew\u00e4hlt.\u00a0H\u00a0<\/span><sub><span>p<\/span><\/sub><span>\u00a0(10) wird auch als\u00a0<\/span><strong><span>Tiefendosis\u00e4quivalent bezeichnet<\/span><\/strong><span>\u00a0.\u00a0Wenn das pers\u00f6nliche Dosimeter an einer Position des K\u00f6rpers getragen wird, die f\u00fcr seine Exposition repr\u00e4sentativ ist, bei niedrigen Dosen und unter der Annahme einer gleichm\u00e4\u00dfigen Ganzk\u00f6rperexposition liefert der Wert von Hp (10) einen effektiven Dosiswert, der f\u00fcr Strahlenschutzzwecke ausreichend genau ist .\u00a0Neutronen- und Gammastrahlung tragen sowohl zur tiefen als auch zur flachen Dosis bei, aber die Beta-Strahlung wird vollst\u00e4ndig von der Haut absorbiert und tr\u00e4gt daher nur zur flachen Dosis bei.<\/span><\/p>\n<p><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min.png\"><img loading=\"lazy\" class=\"aligncenter size-large wp-image-25493 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" alt=\"Strahlungsmessung und -\u00fcberwachung - Mengen und Grenzen\" width=\"1024\" height=\"600\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Dieser Artikel basiert auf der maschinellen \u00dcbersetzung des englischen Originalartikels. Weitere Informationen finden Sie im Artikel auf Englisch. Sie k\u00f6nnen uns helfen. Wenn Sie die \u00dcbersetzung korrigieren m\u00f6chten, senden Sie diese bitte an: translations@nuclear-power.com oder f\u00fcllen Sie das Online-\u00dcbersetzungsformular aus. Wir bedanken uns f\u00fcr Ihre Hilfe und werden die \u00dcbersetzung so schnell wie m\u00f6glich aktualisieren. Danke.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u00c4quivalent zu einer tiefen Dosis &#8211; \u00c4quivalent zu einer flachen Dosis.\u00a0HP (0,07) wird auch als flaches Dosis\u00e4quivalent bezeichnet.\u00a0F\u00fcr die Beurteilung tiefer Organe und die Kontrolle der wirksamen Dosis wird Hp (10) mit einer Tiefe d = 10 mm gew\u00e4hlt.\u00a0HP (10) wird auch als \u00c4quivalent f\u00fcr tiefe Dosen bezeichnet.\u00a0Strahlendosimetrie Im Allgemeinen definiert die ICRP Betriebsgr\u00f6\u00dfen f\u00fcr\u00a0Bereich\u00a0und\u00a0individuelle &#8230; <a title=\"Was ist Deep Dose Equivalent &#8211; Shallow Dose Equivalent &#8211; Definition\" class=\"read-more\" href=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/\" aria-label=\"Mehr dazu unter Was ist Deep Dose Equivalent &#8211; Shallow Dose Equivalent &#8211; Definition\">Weiterlesen<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[48],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Was ist Deep Dose Equivalent - Shallow Dose Equivalent - Definition<\/title>\n<meta name=\"description\" content=\"\u00c4quivalent zu einer tiefen Dosis - \u00c4quivalent zu einer flachen Dosis. HP (0,07) wird auch als flaches Dosis\u00e4quivalent bezeichnet. F\u00fcr die Beurteilung tiefer Organe und die Kontrolle der wirksamen Dosis wird Hp (10) mit einer Tiefe d = 10 mm gew\u00e4hlt. HP (10) wird auch als \u00c4quivalent f\u00fcr tiefe Dosen bezeichnet. Strahlendosimetrie\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Was ist Deep Dose Equivalent - Shallow Dose Equivalent - Definition\" \/>\n<meta property=\"og:description\" content=\"\u00c4quivalent zu einer tiefen Dosis - \u00c4quivalent zu einer flachen Dosis. HP (0,07) wird auch als flaches Dosis\u00e4quivalent bezeichnet. F\u00fcr die Beurteilung tiefer Organe und die Kontrolle der wirksamen Dosis wird Hp (10) mit einer Tiefe d = 10 mm gew\u00e4hlt. HP (10) wird auch als \u00c4quivalent f\u00fcr tiefe Dosen bezeichnet. Strahlendosimetrie\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2019-12-27T23:18:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-09T18:11:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"http:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/Radiation-Measuring-and-Monitoring-Quantities-and-Limits-min-1024x600.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/\",\"name\":\"Was ist Deep Dose Equivalent - Shallow Dose Equivalent - Definition\",\"isPartOf\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/#primaryimage\"},\"datePublished\":\"2019-12-27T23:18:55+00:00\",\"dateModified\":\"2020-07-09T18:11:02+00:00\",\"author\":{\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"\\u00c4quivalent zu einer tiefen Dosis - \\u00c4quivalent zu einer flachen Dosis. HP (0,07) wird auch als flaches Dosis\\u00e4quivalent bezeichnet. F\\u00fcr die Beurteilung tiefer Organe und die Kontrolle der wirksamen Dosis wird Hp (10) mit einer Tiefe d = 10 mm gew\\u00e4hlt. HP (10) wird auch als \\u00c4quivalent f\\u00fcr tiefe Dosen bezeichnet. Strahlendosimetrie\",\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/de\/was-ist-deep-dose-equivalent-shallow-dose-equivalent-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"http:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts\/13956"}],"collection":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/comments?post=13956"}],"version-history":[{"count":0,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/posts\/13956\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/media?parent=13956"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/categories?post=13956"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.radiation-dosimetry.org\/de\/wp-json\/wp\/v2\/tags?post=13956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}