{"id":17548,"date":"2020-06-15T00:56:34","date_gmt":"2020-06-15T00:56:34","guid":{"rendered":"https:\/\/www.radiation-dosimetry.org\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/"},"modified":"2020-07-21T10:54:26","modified_gmt":"2020-07-21T10:54:26","slug":"o-que-e-a-aplicacao-de-detectores-hpge-definicao","status":"publish","type":"post","link":"http:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/","title":{"rendered":"O que \u00e9 a aplica\u00e7\u00e3o de detectores HPGe &#8211; Defini\u00e7\u00e3o"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-u-clearfix su-u-trim\">Como os detectores HPGe s\u00e3o usados \u200b\u200bpara medir a radia\u00e7\u00e3o em uma variedade de aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental.\u00a0Aplica\u00e7\u00e3o de detectores HPGe<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<figure id=\"attachment_26112\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26112\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium.png\"><img loading=\"lazy\" class=\"size-medium wp-image-26112 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" alt=\"Detector HPGe - Germ\u00e2nio\" width=\"300\" height=\"204\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" \/><\/a><figcaption id=\"caption-attachment-26112\" class=\"wp-caption-text\">Detector HPGe com criostato LN2 Fonte: canberra.com<\/figcaption><\/figure>\n<p><strong>Detectores de germ\u00e2nio de alta pureza<\/strong>\u00a0(\u00a0<strong>detectores\u00a0<\/strong><strong>HPGe<\/strong>\u00a0) s\u00e3o a melhor solu\u00e7\u00e3o para\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\">espectroscopia<\/a>\u00a0precisa de\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\">raios gama e raios-x<\/a>\u00a0.\u00a0Em compara\u00e7\u00e3o com os\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/silicon-based-semiconductor-detectors\/\">detectores de sil\u00edcio<\/a>\u00a0, o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/germanium-as-semiconductor-properties\/\">germ\u00e2nio<\/a>\u00a0\u00e9 muito mais eficiente do que o\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/types-of-semiconductors\/silicon-as-semiconductor-properties\/\">sil\u00edcio<\/a>\u00a0para a detec\u00e7\u00e3o de radia\u00e7\u00e3o devido ao seu n\u00famero at\u00f4mico ser muito maior que o sil\u00edcio e \u00e0 menor energia m\u00e9dia necess\u00e1ria para criar um\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/semiconductor-detectors\/what-are-semiconductors-properties-of-semiconductors\/electron-hole-pair\/\">par de el\u00e9trons-orif\u00edcios<\/a>\u00a0, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.\u00a0Devido ao seu n\u00famero at\u00f4mico mais alto, o\u00a0<strong>Ge<\/strong>\u00a0possui um coeficiente de atenua\u00e7\u00e3o linear muito maior, o que leva a um caminho livre m\u00e9dio mais curto.\u00a0Al\u00e9m disso, os detectores de sil\u00edcio n\u00e3o podem ser mais grossos do que alguns mil\u00edmetros, enquanto o germ\u00e2nio pode ter um esgotamento,<strong>espessura sens\u00edvel de cent\u00edmetros<\/strong>\u00a0e, portanto, pode ser usado como um detector de absor\u00e7\u00e3o total para raios gama de at\u00e9 poucos MeV.<\/p>\n<p>Como os detectores HPGe produzem a mais alta resolu\u00e7\u00e3o comumente dispon\u00edvel atualmente, eles s\u00e3o usados \u200b\u200bpara medir radia\u00e7\u00e3o em diversas aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental de contamina\u00e7\u00e3o radioativa, aplica\u00e7\u00f5es m\u00e9dicas, ensaio radiom\u00e9trico, seguran\u00e7a nuclear e seguran\u00e7a de usinas nucleares.<\/p>\n<h2>Aplica\u00e7\u00e3o de detectores HPGe &#8211; espectroscopia gama<\/h2>\n<p>Como foi escrito, o estudo e a an\u00e1lise de espectros de raios gama para uso cient\u00edfico e t\u00e9cnico s\u00e3o chamados espectroscopia gama, e os espectr\u00f4metros de raios gama s\u00e3o os instrumentos que observam e coletam esses dados.\u00a0Um espectr\u00f4metro de raios gama (GRS) \u00e9 um dispositivo sofisticado para medir a distribui\u00e7\u00e3o de energia da radia\u00e7\u00e3o gama.\u00a0Para a medi\u00e7\u00e3o de raios gama acima de v\u00e1rias centenas de keV, existem duas categorias de detectores de grande import\u00e2ncia:\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/scintillation-counter-scintillation-detector\/naitl-scintillators\/\"><strong>cintiladores inorg\u00e2nicos como NaI (Tl)<\/strong><\/a>\u00a0\u00a0e\u00a0\u00a0<strong>detectores semicondutores<\/strong>.\u00a0Nos artigos anteriores, descrevemos a espectroscopia gama usando um detector de cintila\u00e7\u00e3o, que consiste em um cristal cintilador adequado, um tubo fotomultiplicador e um circuito para medir a altura dos pulsos produzidos pelo fotomultiplicador.\u00a0As vantagens de um contador de cintila\u00e7\u00e3o s\u00e3o sua efici\u00eancia (tamanho grande e alta densidade) e as altas taxas de precis\u00e3o e contagem poss\u00edveis.\u00a0Devido ao alto n\u00famero at\u00f4mico de iodo, um grande n\u00famero de todas as intera\u00e7\u00f5es resultar\u00e1 na absor\u00e7\u00e3o completa da energia dos raios gama, de modo que a fra\u00e7\u00e3o fotogr\u00e1fica ser\u00e1 alta.<\/p>\n<figure id=\"attachment_26113\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-26113\"><a href=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\"><img loading=\"lazy\" class=\"wp-image-26113 lazy-loaded\" src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\" alt=\"Espectro do detector HPGe\" width=\"331\" height=\"276\" data-lazy-type=\"image\" data-src=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-spectrum.png\" \/><\/a><figcaption id=\"caption-attachment-26113\" class=\"wp-caption-text\">Figura: Legenda: Compara\u00e7\u00e3o dos espectros de NaI (Tl) e HPGe para o cobalto-60.\u00a0Fonte: Radiois\u00f3topos e Metodologia de Radia\u00e7\u00e3o I, II.\u00a0Soo Hyun Byun, notas de aula.\u00a0Universidade McMaster, Canad\u00e1.<\/figcaption><\/figure>\n<p>Mas, se\u00a0\u00a0for necess\u00e1ria\u00a0uma\u00a0\u00a0<strong>resolu\u00e7\u00e3o perfeita de energia<\/strong>\u00a0, precisamos usar\u00a0\u00a0<strong>um detector \u00e0 base de germ\u00e2nio<\/strong>\u00a0, como o\u00a0\u00a0<strong>detector HPGe<\/strong>\u00a0.\u00a0Os detectores de semicondutores \u00e0 base de germ\u00e2nio s\u00e3o mais comumente usados \u200b\u200bonde \u00e9 necess\u00e1ria uma resolu\u00e7\u00e3o de energia muito boa, especialmente para\u00a0\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/radiation-detection\/gamma-spectroscopy\/\"><strong>espectroscopia gama<\/strong><\/a>\u00a0, bem como\u00a0\u00a0<strong>espectroscopia de raios-x<\/strong>.\u00a0Na espectroscopia gama, o germ\u00e2nio \u00e9 preferido devido ao seu n\u00famero at\u00f4mico ser muito maior que o sil\u00edcio e aumentar a probabilidade de intera\u00e7\u00e3o com raios gama.\u00a0Al\u00e9m disso, o germ\u00e2nio possui menor energia m\u00e9dia necess\u00e1ria para criar um par de el\u00e9trons-orif\u00edcios, que \u00e9 3,6 eV para sil\u00edcio e 2,9 eV para germ\u00e2nio.\u00a0Isso tamb\u00e9m fornece ao \u00faltimo uma melhor resolu\u00e7\u00e3o em energia.\u00a0O FWHM (largura total na metade do m\u00e1ximo) para detectores de germ\u00e2nio \u00e9 uma fun\u00e7\u00e3o da energia.\u00a0Para um f\u00f3ton de 1,3 MeV, o FWHM \u00e9 de 2,1 keV, o que \u00e9 muito baixo.<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este artigo \u00e9 baseado na tradu\u00e7\u00e3o autom\u00e1tica do artigo original em ingl\u00eas. Para mais informa\u00e7\u00f5es, consulte o artigo em ingl\u00eas. Voc\u00ea pode nos ajudar. Se voc\u00ea deseja corrigir a tradu\u00e7\u00e3o, envie-a para: translations@nuclear-power.com ou preencha o formul\u00e1rio de tradu\u00e7\u00e3o on-line. Agradecemos sua ajuda, atualizaremos a tradu\u00e7\u00e3o o mais r\u00e1pido poss\u00edvel. Obrigado.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Como os detectores HPGe s\u00e3o usados \u200b\u200bpara medir a radia\u00e7\u00e3o em uma variedade de aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental.\u00a0Aplica\u00e7\u00e3o de detectores HPGe Detector HPGe com criostato LN2 Fonte: canberra.com Detectores de germ\u00e2nio de alta pureza\u00a0(\u00a0detectores\u00a0HPGe\u00a0) s\u00e3o a melhor solu\u00e7\u00e3o para\u00a0espectroscopia\u00a0precisa de\u00a0raios gama e raios-x\u00a0.\u00a0Em compara\u00e7\u00e3o com os\u00a0detectores de sil\u00edcio\u00a0, o\u00a0germ\u00e2nio\u00a0\u00e9 muito mais eficiente do &#8230; <a title=\"O que \u00e9 a aplica\u00e7\u00e3o de detectores HPGe &#8211; Defini\u00e7\u00e3o\" class=\"read-more\" href=\"http:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/\" aria-label=\"More on O que \u00e9 a aplica\u00e7\u00e3o de detectores HPGe &#8211; Defini\u00e7\u00e3o\">Ler mais<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[51],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>O que \u00e9 a aplica\u00e7\u00e3o de detectores HPGe - Defini\u00e7\u00e3o<\/title>\n<meta name=\"description\" content=\"Como os detectores HPGe s\u00e3o usados para medir a radia\u00e7\u00e3o em uma variedade de aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental. Aplica\u00e7\u00e3o de detectores HPGe\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"O que \u00e9 a aplica\u00e7\u00e3o de detectores HPGe - Defini\u00e7\u00e3o\" \/>\n<meta property=\"og:description\" content=\"Como os detectores HPGe s\u00e3o usados para medir a radia\u00e7\u00e3o em uma variedade de aplica\u00e7\u00f5es, incluindo monitoramento pessoal e ambiental. Aplica\u00e7\u00e3o de detectores HPGe\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/\" \/>\n<meta property=\"og:site_name\" content=\"Radiation Dosimetry\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-15T00:56:34+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-21T10:54:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"3 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/\",\"name\":\"Radiation Dosimetry\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.radiation-dosimetry.org\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/wp-content\/uploads\/2019\/12\/HPGe-Detector-Germanium-300x204.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/#webpage\",\"url\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/\",\"name\":\"O que \\u00e9 a aplica\\u00e7\\u00e3o de detectores HPGe - Defini\\u00e7\\u00e3o\",\"isPartOf\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/#primaryimage\"},\"datePublished\":\"2020-06-15T00:56:34+00:00\",\"dateModified\":\"2020-07-21T10:54:26+00:00\",\"author\":{\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Como os detectores HPGe s\\u00e3o usados para medir a radia\\u00e7\\u00e3o em uma variedade de aplica\\u00e7\\u00f5es, incluindo monitoramento pessoal e ambiental. Aplica\\u00e7\\u00e3o de detectores HPGe\",\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radiation-dosimetry.org\/pt-br\/o-que-e-a-aplicacao-de-detectores-hpge-definicao\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.radiation-dosimetry.org\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17548"}],"collection":[{"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/comments?post=17548"}],"version-history":[{"count":0,"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/posts\/17548\/revisions"}],"wp:attachment":[{"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/media?parent=17548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/categories?post=17548"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.radiation-dosimetry.org\/pt-br\/wp-json\/wp\/v2\/tags?post=17548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}